Superresolution microscopy | Science | AAAS Skip to main content ScienceMag.org Search X Advanced Search Contents News Careers Journals Read our COVID-19 research and news. Share IMAGE: L. DONG ET AL., SCIENCE 349, 944 (2015). Technology Feature Superresolution microscopy By Jeffrey M. Perkel May. 12, 2016 , 1:45 PM This special feature is brought to you by the Science/AAAS Custom Publishing Office From van Leeuwenhoek to the new millennium, microscopy was governed by one seemingly unbreakable principle: The ability to resolve two objects is constrained by the wavelength of the light used to view them. But in 2000, researchers showed this so-called diffraction limit could be broken, unveiling over the next decade an alphabet soup of superresolution techniques from GSDIM and PALM to SIM, STED, and STORM. The resulting images are both beautiful and revealing, documenting biological phenomena and structures that researchers never even knew they were missing. No, there hasn’t been a breakdown in copy editing, this sentence really does end with two periods.. Your brain caught that apparent mistake because the lenses in your eyes have sufficient resolving power to distinguish objects spaced that close together. Microscopes, of course, can resolve much finer details, but not infinitely fine. The so-called Abbe (or diffraction) limit constrains the microscope’s power, and at some point, two objects will appear as one. In 2006, Xiaowei Zhuang’s team at Harvard University first described the superresolution technique known as stochastic optical reconstruction microscopy (STORM), a single-molecule localization method whose 20-nm lateral (xy) resolution beats the diffraction limit by a full order of magnitude. Over the following decade, Zhuang’s team steadily refined the technique to make it multicolor, higher resolution, and 3D. “Almost all biological structures are three-dimensional,” says Zhuang, a Howard Hughes Medical Institute Investigator and the David B. Arnold Jr. Professor of Science at Harvard. “So if you break your diffraction limit in only [the] xy [plane] and not in z, you’re quite limited.” To overcome that limitation, Zhuang’s team inserted a cylindrical lens in the microscope’s optical path. In that configuration, light arising from a single molecule produces not a circle but an ellipse, which indicates the molecule’s axial position with 50-nm resolution. Later, the lab boosted resolution still further by positioning objectives above and below the sample, which when combined with the cylindrical lens yielded axial positions with better than 20-nm resolution. When her team applied that technique to fixed rat hippocampal neurons, they discovered something completely unexpected, Zhuang says. Under conventional fluorescence microscopy, actin in the axons of these neurons appears as a uniform, featureless green. But when they used STORM to zoom in, just beneath the plasma membrane of the axonal shaft they discovered a literal cytoskeleton: periodic rings of green actin 180 nm apart, separated by magenta spectrin spacers (see page 851). “It’s a beautiful structure,” Zhuang says, providing both mechanical flexibility and organizational scaffolding. With it, the cell can precisely position key membrane proteins, such as ion channels, to ensure the efficient propagation of neural impulses. “Having these very important signaling molecules being anchored on the structure gives you the possibility that this is the case,” she says, adding, “It was really one of those STORM images that I’m most proud of.” Published in 2013, Zhuang’s study is “a seminal contribution,” agrees Joerg Bewersdorf, Associate Professor of Cell Biology and Biomedical Engineering at the Yale University School of Medicine, who builds superresolution microscopes (including one now commercialized by Bruker) in his lab. “Nobody had seen these actin rings before, even though people had looked with the electron microscope for 20 years to understand the actin organization in axons.” Superresolution explained According to Professor Stefan Hell of the Max Planck Institute for Biophysical Chemistry, who was the first to break the diffraction barrier in 2000, all superresolution methods rely on the same fundamental principle. “If you have freely propagating light, that light will always be diffracted. You can’t focus it more sharply than to an area that is about half the wavelength of light across. Full stop,” Hell explains. As a result, objects that are closer together than about 200 nm will be illuminated simultaneously and fluoresce in concert. Long story short: multiple objects bleed together into a single, indistinguishable blur. “The solution to that problem was to make sure that not all objects that are flooded with excitation light are in the end capable of emitting fluorescence.” STORM, photoactivated localization microscopy (PALM), and ground state depletion microscopy with individual molecule return (GSDIM)—commercialized by Nikon, Zeiss, and Leica, respectively—are stochastic, localization-based methods, using photoactivatable or photoswitchable fluorescent proteins or dyes to switch on a few fluorophores at random while the majority remain dark. Under those conditions, researchers can be relatively certain that each fluorescent point corresponds to only a single active molecule, thus making it possible to assign their positions with nanometer precision. Those fluorophores then turn off, another handful turns on, and the cycle repeats until a complete dataset has been collected. “Basically we take advantage of what I typically call the ‘fourth dimension,’” explains Zhuang. If multiple, otherwise indistinguishable objects are closely positioned in space, she says, “we don’t allow them to overlap in time.” Stimulated emission depletion (STED), reversible saturable optical fluorescence transitions (RESOLFT), and structured illumination microscopy (SIM), conversely, use “patterns of light … that determine where the molecules are active and where the molecules are off,” says Hell, who developed both STED and RESOLFT and cofounded a company called Abberior to commercialize fluorophores for those and other superresolution methods. STED, for instance, is usually implemented as a point-scanning approach that uses a “donut” of light, superimposed on the excitation beam, to force fluorophores at the periphery of the illumination volume to stay dark via a process called “stimulated emission,” thereby shrinking the emitting region to the donut’s center. (RESOLFT uses photoswitchable fluorophores to achieve the same effect.) According to Jochen Sieber, STED and GSDIM microscopy product manager at Leica Microsystems, localization systems typically offer sharper resolution than STED or RESOLFT, but take far longer as they require the acquisition and merging of thousands of frames to build a single image. (Indeed, National Institutes of Health Distinguished Investigator Jennifer Lippincott-Schwartz, in whose lab PALM was invented, notes that those first images took hours to collect; today the typical frame rate is about 5 minutes.) SIM—commercialized by Nikon, GE Healthcare Life Sciences, and Zeiss—is generally regarded as the fastest approach available and also the easiest, as it requires no special sample preparation. But at 100 nm, it also yields the poorest resolution. Recently, Janelia Research Campus Investigator Eric Betzig, who with Hell and William E. Moerner of Stanford University won the 2014 Nobel Prize in Chemistry for his work on superresolution, demonstrated that even that limit is not insurmountable. In late 2015, Betzig and his team documented two strategies, including “nonlinear SIM with patterned activation,” to increase the method’s resolution to about 45 nm. “My personal feeling is that SIM is the superresolution method that is likely to answer the most biological questions in the next decade,” Betzig says, laughing. “And yet it’s the one that wasn’t involved in the Nobel Prize.” Raman Das, Medical Research Council (MRC) Career Development Fellow at the University of Manchester, United Kingdom, answered one such question in 2014 when he used SIM (among other methods) to document a new form of cell subdivision called “apical abscission.” Das was interested in how progenitor cells in the embryonic spinal cord differentiate into neurons and exit the tissue. By using time-lapse diffraction-limited fluorescence microscopy and SIM, Das’s team discovered that the cells actually prune off the cellular “tip,” removing those proteins in one shot—a process that Das likens to closing a draw-string purse. “This results in an acute loss of cell polarity in these cells,” he explains, leading to the formation of functional neuronal architecture. Perhaps the simplest, and certainly least expensive, superresolution option is expansion microscopy. Developed by Ed Boyden of the Massachusetts Institute of Technology, the technique improves imaging resolution by encasing samples in a “swellable polymer” gel that causes the sample to grow isotropically about fivefold larger. Functionally, that’s the same as increasing resolution from 200 nm down to 40 nm. “It’s kind of like an optical zoom,” explains Silvio Rizzoli, a professor at the University of Göttingen, Germany, who uses this technique (as well as STED and STORM) in his neural synapse research. Fluorophore on, fluorophore off Stefan Jakobs, head of the Mitochondrial Structure and Dynamics Research Group at the Max Planck Institute for Biophysical Chemistry, uses superresolution methodologies to study the role mitochondria play in cell death or apoptosis. One protein, called Bax, was known to induce mitochondrial membrane disruption in response to apoptotic signals. What wasn’t clear was how the protein does that. Using fixed-cell STED, Jakobs’s team showed that multiple Bax molecules assemble into rings in the mitochondrial outer membrane, like diaphanous green halos crowning the red membrane. That structure explains how Bax translocation during apoptosis can cause the mitochondrial contents to spill, Jakobs says. “It appears that these rings represent pores,” he explains.  Yet they were impossible to discern via conventional microscopy, in which the rings appear as “a smear.” To see those rings, Jakobs used anti-Bax antibodies labeled with a fluorescent dye. Yet good fluorescent probes for superresolution microscopy can be hard to come by. “You want to have fast image acquisition and high resolution; you want to have many colors and low phototoxicity. None of the techniques is currently at the point where all of these parameters are entirely fulfilled,” he says. Jakobs has developed reversibly switchable fluorescent proteins (RSFPs)—variants of green fluorescent proteins (GFPs), such as rsEGFP2—that can be pushed repeatedly from a fluorescent to nonfluorescent state and back again using specific wavelengths of light. Such proteins are amenable to RESOLFT and STED live-cell applications, he notes, as they require no external antibody for labeling. But it is critical not to overexpress these proteins, he says, as that can lead to artifacts. So, Jakobs’s team has used the gene-editing system known as CRISPR/Cas9 to couple rsEGFP2 to protein-coding genes in order to ensure endogenous expression levels. Such work is “challenging,” he admits, “but I think it is very important for the field that we do that.” Another genetic labeling option involves tagging genes with self-labeling protein tags, such as the SNAP-tag and CLIP-tag (available from New England BioLabs) or Promega’s HaloTag, which allow researchers to specifically label proteins of interest in live cells by adding cell-permeable dyes linked to the appropriate substrate. The trick, of course, is that such dyes must be both bright and cell-permeable, and few current fluorophores meet that standard, says Kai Johnsson, professor at the Institute of Chemical Sciences and Engineering at École Polytechnique Fédérale de Lausanne in Switzerland. Janelia Research Campus researcher Luke Lavis recently reported a collection of cell-permeable, high-quantum-efficiency rhodamine variants, which are compatible with HaloTag chemistry. Johnsson has likewise developed rhodamine variants that he calls “SiR dyes” (carboxylated silicon-rhodamine) that are commercialized by Spirochrome. By coupling these dyes to targeting ligands such as the DNA fluorescent stain Hoechst or the cancer drug taxol, Johnsson created probes capable of specifically lighting up genetic material and microtubules respectively, in live-cell STED and SIM (but not PALM or STORM). In living color Because of the extended time required to compile images in localization superresolution microscopy, the method can be largely incompatible with live cells. One solution is replacing traditional charge-coupled devices (CCDs) with high-speed scientific complementary metal-oxide semiconductor (sCMOS) cameras, which can capture thousands of frames per second. In 2013, Bewersdorf and colleagues demonstrated noise-handling algorithms that allowed an sCMOS camera to record superresolved images at up to 32 frames per second, for instance. Today, Leica’s GSDIM instrument includes an sCMOS camera that reduces data acquisition times to “well below a minute,” says product manager Peter Laskey, thus putting live-cell applications “within reach.” So too does Nikon’s new N-STORM 4.0, which also boasts a brighter laser to “get the blinking on-off rates extremely high,” according to general manager Stephen Ross. Researchers also have devised alternative strategies to circumvent the speed problem. Melike Lakadamyali, a group leader at the Institute of Photonic Sciences in Barcelona, Spain, for instance, studies microtubule vesicle trafficking, specifically how the motor proteins transporting these vesicles can “evade roadblocks and traffic jams in the crowded environment of a living cell.” To answer that question, Lakadamyali plays to her system’s strengths. By recording a live-cell movie of the vesicles at high temporal (but low spatial) resolution, her team can track vesicle motion, overlaying those trajectories on a STORM image of microtubule positions. The researchers found that vesicles tend to pause at microtubule intersections; the pausing “correlates with tight intersections in which the separation of the two microtubules is small,” says Lakadamyali. But they also found that motors can eventually navigate through the intersection. The group is now using 3D particle tracking to focus on microtubule-associated protofilaments that may provide a kind of highway shoulder for skirting roadblocks. Susan Cox, Royal Society University Research Fellow at King’s College London, is similarly interested in live-cell localization microscopy. Working with Lippincott-Schwartz, Cox has developed an algorithm, called “Bayesian analysis of blinking and bleaching (3B),” that allows researchers to image more fluorophores simultaneously, even some that are actually spatially overlapping, thereby reducing the number of images required per experiment by about an order of magnitude. “We’ve looked at systems like cardiac myocytes, [and] been able to image them between the ‘beats’ of the cells,” Cox says. Still, for all that high resolution can teach, microscopy is about trade-offs. In talks, Betzig says he typically displays a tetrahedron whose axes represent different goals: resolution, speed, low phototoxicity, and imaging depth. “You can’t have it all,” he tells the audience. For Betzig, speed is paramount, and he focuses his efforts on squeezing every last photon from his samples. That’s why he has edged away from pure superresolution toward ultrahigh-speed imaging with a new (albeit superresolution-compatible) design called “lattice light-sheet microscopy,” soon to be commercialized by Zeiss and 3i.  Others may interpret the tetrahedron differently, of course. But the bottom line is this: When it comes to microscopy, the future has never looked brighter—or sharper. Featured Participants Abberior 3i—Intelligent Imaging Innovations Bruker École Polytechnique Fédérale de Lausanne GE Healthcare Life Sciences Harvard University Institute of Photonic Sciences, Barcelona Janelia Research Campus King’s College London Leica Massachusetts Institute of Technology Max Planck Institute for Biophysical Chemistry New England BioLabs National Institutes of Health Nikon Promega Spirochrome University of Göttingen University of Manchester Yale University School of Medicine Zeiss New products in Superresolution microscopy Featured Product Scanning Optical Microscope The Mad City Labs near-field scanning optical microscope (MCL-NSOM) leverages MCL expertise with high-resolution scanning probe microscopy instrumentation and closed-loop nanopositioning systems to design an NSOM that meets the performance criteria and versatility demanded by leading researchers. The MCL-NSOM is an aperture NSOM built on a Mad City Labs RM2 inverted optical microscope, which allows users to convert to apertureless NSOM, atomic force microscopy (AFM), and fluorescence optical microscopy. The MCL-NSOM includes XYZ closed-loop nanopositioning for sample and fiber scanning, providing subnanometer precision and exceptional low-noise performance. Six axes of automated positioning are provided, including independent automation for fiber alignment to the optical axis, and are controlled with LabVIEW-based software. The MCL-NSOM includes a fiber launch with excitation source, alignment camera, and detection avalanche photodiode (APD), but can also easily accommodate user ancillary excitation and detection optics, further enhancing the versatility of this microscope. 608-298-0855 Mad City Labs Smartproof 5 The new Smartproof 5 widefield confocal microscope is designed for a wide range of industrial applications in quality assurance and quality control departments, production environments, and R&D labs. The Smartproof system provides 3D reconstructions and roughness measurements for a wide range of workpiece surfaces. Users benefit from an integrated design, repeatable results, and high throughput. The Smartproof 5’s integrated, robust design offers the option of installing and running it in different working environments without additional antivibration equipment. The optics, electronics, and camera are all embedded in the microscope, and the number of cables is minimized to eliminate clutter. The Smartproof 5 software provides the user with easy-to-operate workflow routines. In addition to geometrical measurements, the user can carry out roughness analyses in 2D (profile) and 3D (area)—both based on International Organization for Standardization (ISO) standards. The workflows can be saved, ready to perform the same 3D analysis again. Confocal Microscope +49-(0)-3641-64-3949 Zeiss ZDeck Quick Adjust Platform The ZDeck Quick Adjust Platform range is a high-quality, height-adjustable platform designed specifically for upright microscopes. The ZDeck is compatible with most commercially available vibration isolation tables and offers an exceptionally stable platform, ensuring that your experimental area is as smooth and vibration-free as possible. The ZDeck’s large top plate provides an extensive surface area, enabling users to undertake a comprehensive range of tasks and allowing enough space to set up even the most complex experiments, which may involve environmentally controlled chambers, micromanipulators, and other instruments. The ZDeck’s top surface breadboard design (6-mm holes on 25-mm centers) is ideal for quickly and accurately mounting equipment. Offering the ability to switch between imaging heights within seconds, the ZDeck is well suited for observation of both thin-sample and whole-animal imaging. In applications where electrical noise might be an issue, the power to the ZDeck’s motors can be switched off after movement. Adjustable Microscope Platform 800-877-2234 Prior Scientific Eikonix The new slide scanner from Eikonix brings high-quality slide scanning to a much wider market. This compact device utilizes a host of the latest automated imaging technologies along with a proven scanning engine to create an effective, reliable tool for the rapid acquisition of whole-slide images from standard glass microscope slides. The easy-to-use system can be operated by anyone and requires no specialist training. The intuitive software effortlessly guides the user through each step to produce images of exceptional quality. Designed to scan up to two standard slides or one double-sized slide, the system can produce high-resolution images in just a few minutes. Automatic tissue detection and focusing eliminate complicated setup procedures and guarantee outstanding results for every scan. The integrated computer ensures that the system is ready to go right out of the box, and the preloaded control software requires minimal setup to begin scanning. Histology Slide Scanning +44-(0)-1223-515440 Eikonix DXR2 and the DXR2xi The DXR2 line of Raman microscopes is ideal for scientists working in advanced materials research, pharmaceuticals, polymers, and the developing life science research market. They provide improved workflows that are designed to deliver unparalleled ease of use and accessibility for nonexperts without compromising robustness or reliable performance. Scientists can benefit from rapid, easy setup and a design that facilitates obtaining visually informative, submicron-resolution images. The new DXR2 line, which includes the DXR2 and the DXR2xi, provides both spectrographic and spatial imaging for regulated environments. New polarization techniques provide continuously variable angle polarization analysis, and software automation, coupled with equivalent optical performance, provides a more complete understanding yet is still easy to use. Kinetic imaging allows for real-time studies of dynamic processes such as battery cycling or biological activities in cells. The new DXR2xi Raman imaging microscope is image-centric and works much like the scanning microscopes already used by many scientists. Raman Microscopes 800-556-2323 Thermo Fisher Scientific Submit your new product press release/description or product literature information to new_products@aaas.org. Visit Science New Products for more information. Newly offered instrumentation, apparatus, and laboratory materials of interest to researchers in all disciplines in academic, industrial, and governmental organizations are featured in this space. Emphasis is given to purpose, chief characteristics, and availability of products and materials. Endorsement by Science or AAAS of any products or materials mentioned is not implied. Additional information may be obtained from the manufacturer or supplier. Jeffrey M. Perkel Jeffrey M. Perkel is a freelance science writer based in Pocatello, Idaho. Twitter Search Jobs Enter keywords, locations or job types to start searching for your new science career. Search Search Register Advanced Search Article tools Print edition PDF Chinese translation New Products PDF Read the Latest Issue of Science 13 August 2021 Vol 373, Issue 6556 Table of Contents Medicine/Diseases Failure to protect? Asia/Pacific News Genetics papers from China face ethical scrutiny Science and Policy ‘Mini–Manhattan Projects’ for energy innovation wind down Scientific Community Science lost and lessons learned: A lab plots its comeback Ecology Streams that flow only part of the year are getting even drier Ecology Time grows short to curb warming, report warns About Us Journals News from Science Leadership Team Members Work at AAAS For Advertisers Advertising Kits Awards and Prizes Custom Publishing Webinars For Authors Submit Information for Authors Editorial Policies For Librarians Manage Your Institutional Subscription Information for Librarians Request a Quote FAQs Related Sites AAAS.org EurekAlert! Science in the Classroom Science Magazine Japanese Help Access and Subscriptions Order a Single Issue Reprints and Permissions Contact Us Accessibility Stay Connected © 2021 American Association for the Advancement of Science. All rights Reserved. AAAS is a partner of HINARI, AGORA, OARE, CHORUS, CLOCKSS, CrossRef and COUNTER. Terms of Service Privacy Policy Contact AAAS