key: cord-355514-2qjbc3bd authors: Shibata, Shun; Ishiguro, Takashi; Kobayashi, Yasuhito; Koike, Mayumi; Numano, Tsuyoshi; Shimizu, Yoshihiko; Takayanagi, Noboru title: High incidence of false-positive results of IgG antibody against SARS-CoV-2 with rapid immunochromatographic antibody test due to human common cold coronavirus infection date: 2020-07-25 journal: Respir Med Case Rep DOI: 10.1016/j.rmcr.2020.101180 sha: doc_id: 355514 cord_uid: 2qjbc3bd We experienced a 72-year-old man who developed laboratory-confirmed human coronavirus HKU1 pneumonia. PCR testing for SARS-CoV-2 from a nasopharyngeal specimen was negative twice, and rapid immunochromatographic antibody test (RIAT) using a commercially available kit for IgM and IgG against SARS-CoV-2 showed him turning positive for IgG against SARS-CoV-2. We then performed RIAT in stored serum samples from other patients who suffered laboratory-confirmed human common cold coronaviruses (n = 6) and viruses other than coronavirus (influenza virus, n = 3; rhinovirus, n = 3; metapneumovirus, n = 1; adenovirus, n = 1) admitted until January 2019. Including the present case, four of 7 (57%) showed false-positive RIAT results due to human common cold coronaviruses infection. Two of the 4 patients showed initial negative to subsequent positive RIAT results, indicating seroconversion. RIAT was positive for IgG and IgM in viruses other than coronavirus in 2 (25.0%) and 1 (12.5%) patient. Because of high incidence of false positive RIAT results, cross antigenicity between human common cold coronaviruses and SARS-CoV-2 can be considered. Results of RIAT should be interpreted in light of epidemics of human common cold coronaviruses infection. Prevalence of past SARS-CoV-2 infection may be overestimated due to high incidence of false-positive RIAT results. 1 High incidence of false-positive results of IgG antibody against SARS-CoV-2 with rapid immunochromatographic antibody test due to human common cold coronavirus infection 2 We experienced a 72-year-old man who developed laboratory-confirmed human coronavirus HKU1 pneumonia. PCR testing for SARS-CoV-2 from a nasopharyngeal specimen was negative twice, and rapid immunochromatographic antibody test (RIAT) using a commercially available kit for IgM and IgG against SARS-CoV-2 showed him turning positive for IgG against SARS-CoV-2. We then performed RIAT in stored serum samples from other patients who suffered laboratory-confirmed human common cold coronaviruses (n=6) and viruses other than coronavirus (influenza virus, n=3; rhinovirus, n=3; metapneumovirus, n=1; adenovirus, n=1) admitted until January 2019. Including the present case, four of 7 (57%) showed false-positive RIAT results due to human common cold coronaviruses infection. Two of the 4 patients showed initial negative to subsequent positive RIAT results, indicating seroconversion. RIAT was positive for IgG and IgM in viruses other than coronavirus in 2 (25.0%) and 1 (12.5%) patient. Because of high incidence of false positive RIAT results, cross antigenicity between human common cold coronaviruses and SARS-CoV-2 can be considered. Results of RIAT should be interpreted in light of epidemics of human common cold coronaviruses infection. Prevalence of past SARS-CoV-2 infection may be overestimated due to high 3 incidence of false-positive RIAT results. We experienced a 72-year-old man who developed laboratory-confirmed human coronavirus HKU1 pneumonia. PCR testing for SARS-CoV-2 from a nasopharyngeal specimen was negative twice, and rapid immunochromatographic antibody test (RIAT) using a commercially available kit for IgM and IgG against SARS-CoV-2 showed him turning positive for IgG against SARS-CoV-2. We then performed RIAT in stored serum samples from other patients who suffered laboratory-confirmed human common cold coronaviruses (n=6) and viruses other than coronavirus (influenza virus, n=3; rhinovirus, n=3; metapneumovirus, n=1; adenovirus, n=1) admitted until January 2019. Including the present case, four of 7 (57%) showed false-positive RIAT results due to human common cold coronaviruses infection. Two of the 4 patients showed initial negative to subsequent positive RIAT results, indicating seroconversion. RIAT was positive for IgG and IgM in viruses other than coronavirus in 2 (25.0%) and 1 (12.5%) patient. Because of high incidence of false positive RIAT results, cross antigenicity between human common cold coronaviruses and SARS-CoV-2 can be considered. Results of RIAT should be interpreted in light of epidemics of human common cold coronaviruses infection. Prevalence of past SARS-CoV-2 infection may be overestimated due to high incidence of false-positive RIAT results. Novel coronavirus SARS-CoV-2 (Severe acute respiratory syndrome coronavirus 2) is causing a worldwide pandemic of coronavirus disease 2019 (COVID-19) that has resulted in many deaths. Some governments are suggesting an 'immunity passport' or 'risk-free certificate' based on SARS-CoV-2 antibody detection that could allow people to travel or go to work under the assumption that they cannot be re-infected; however, there is scant evidence on antibody-mediated immunity to SARS-CoV-2 to validate such an 'immunity passport'. Further, epidemiological surveillance by serological approaches are also have been started. However, scientists are afraid of the possibility of false-positive results due to cross-reaction of antibodies between SARS-CoV-2 and human common cold coronaviruses [1] . World Health Organization suggests that rapid immunochromatographic antibody testing (RIAT) must also accurately discriminate between past SARS-CoV-2 infections and infection from human common cold coronaviruses [2]. However, no studies have clarified whether human common cold coronaviruses infections cause false-positive results of RIAT for SARS-CoV-2. A 72-year-old man who had undergone aortic stenting for abdominal aneurysm at 70 6 years of age developed dyspnea and low-grade fever in March 2020 (day 1). He developed cough and fever >38ºC from day 7. He presented to our hospital on day 12 for regular follow up by his cardiologist, and chest X-ray (Fig. 1a) ng/dL. His beta-D glucan value was < 6.0 pg/mL, and KL-6 value was slightly elevated at 508 U/mL. We considered COVID-19 and performed a PCR test for SARS-CoV-2, which was negative, but human coronavirus HKU1 was detected by multiplex PCR test via a commercially available kit (FTD Resp 21 Kit; Fast Track Diagnostics, Silema, Malta). Rapid test for urinary Streptococcus pneumoniae antigen, Legionella antigen, and nasopharyngeal influenza virus and Mycoplasma pneumoniae were all negative. Serum antibodies against HIV and Trichosporon asahii, which is the most frequent antigen of hypersensitivity pneumonitis in Japan, were negative He was admitted to our hospital on day 17 (hospital day [HD] 1) and was followed up without antibiotics. However, his fever continued (Fig. 2) , and general fatigue increased after admission. Blood gas analysis under ambient air on HD 5 showed a PaO 2 of 72.6 Torr. Chest CT performed on HD 5 showed worsening of ground-glass opacities and consolidation (Fig. 1c) . We performed RIAT using a commercially available kit (RF-NC0001, RF-NC0002 with lateral flow style, KURABO Ltd., Osaka, Japan) for IgM and IgG against SARS-CoV-2, which was positive for IgG. We repeated RIAT on HD 6 and received the same result. We repeated both PCR testing for SARS-CoV-2 and multiplex PCR using nasopharyngeal swab specimens, which were negative for SARS-CoV-2 but again positive for human coronavirus HKU1. We performed RIAT using preserved frozen serum obtained on admission, which showed negative results for both IgM and IgG, 8 indicating seroconversion. His body temperature gradually improved, and his PaO 2 on HD 9 had risen to 89.7 Torr. Pulmonary shadows on CT also improved, and he was discharged on HD 14. After returning to home, his symptoms have never relapsed. Serum antibodies against influenza virus, Mycoplasma pneumoniae, Chlamydophila pneumoniae, C. psittaci, respiratory syncytial virus, adenovirus, and parainfluenza virus did not increase in the convalescent phase, and we ultimately diagnosed the patient as having primary human coronavirus HKU1 pneumonia. We experienced a patient suffering human coronavirus HKU1 pneumonia who showed false-positive results for IgG against SARS-CoV-2 using an RIAT. An excellent sensitivity of RIAT for SARS-CoV-2 has been reported. We performed RIAT using a commercially available kit for IgM and IgG against SARS-CoV-2 in serum samples of 24 patients with laboratory-confirmed COVID-19 (admitted from February to April 2020), 7 patients with human common cold coronavirus pneumonia (Table 1) and IgM with median 12 days from illness onset was compatible with previous reports [3, 4] . On the other hand, four (57%) of the 7 patients with human common cold coronavirus pneumonia showed positive IgG against SARS-CoV-2, and all but one showed negative IgM (Table 1) . One patient (Case 7, the present case) repeatedly showed negative nasopharyngeal PCR results for SARS-CoV-2 but positive results for human coronavirus HKU1 PCR. Two patients showed seroconversion of IgG against SARS-CoV-2. We speculated that IgG antibody against human common cold coronavirus infection had cross-reacted to SARS-CoV-2 antibody and showed 10 seroconversion. Because of sequence identity between human common cold coronaviruses (HKU1, OC43, NL63, 229E) and SARS-CoV-2 [5] , cross antigenicity can be considered. Recent study suggests cross-reactive T-cell recognition between circulating human common cold coronaviruses and SARS-CoV-2 [6] . Another study also showed that antibodies to human common cold coronavirus are cross-reactive among coronavirus strains [7] . Three of the 7 patients showed negative RIAT results, 2 of whom were tested within 2 weeks of illness onset. Poor positive rates of IgM and IgG against SARS-CoV-2 have been reported in the early phase improved in >2 weeks [3, 4] . This may have affected our RIAT test results showing negative in 3 of our 7 patients, 2 of whom were tested within 2 weeks of illness onset. Further, 8 patients with viral pneumonia due to H1N1 influenza (n=3), adenovirus (n=1), rhinovirus (n=3), and human metapneumovirus (n=1) showed positive IgG in 2 patients (25.0%) (those with H1N1 influenza and rhinovirus) and positive IgM in the one patient with H1N1 influenza (12.5%). We considered these patients to have had a previous human common cold coronavirus infection. It has not fully known how long antibodies against human common cold coronavirus last, whereas IgG antibodies against SARS-CoV last for 3 years [8] . Cross-reactivity is potentially a limitation of immunoassays as it impacts the 11 reliability of the test. Our results indicated that test specificity may decrease when patients with human common cold coronavirus infections are included in a control group. From this high incidence of false-positive RIAT results due to human common cold coronavirus infection found in our study, our concern is that people not infected by SARS-CoV-2 but infected by human common cold coronavirus can be falsely labelled as positive. They may then receive an 'immunity-passport' and be exposed to To date, development of commercial antibody tests is accelerating in numerous companies. Because the number of cases reported here is limited, further studies are needed to determine the accuracy, reliability, and performance of RIAT. In conclusion, we treated a patient with human coronavirus HKU1 pneumonia who showed false-positive IgG results from a RIAT. We found a high incidence of false-positive RIAT results in patients with human common coronavirus pneumonia. Physicians and epidemiologists should consider the possibility that patients infected There were no pleural effusions or significant lymphadenopathy. Chest CT performed on HD 5 showed worsening of ground-glass opacities and consolidation (c). Body temperature decreased to <37ºC on hospital day 8. C-reactive protein gradually decreased. Blood gas analysis worsened after admission and then improved. IgG antibody against SARS-CoV-2 was negative on admission but turned positive. IgM antibody against SARS-CoV-2 was negative throughout the clinical course. Developing antibody tests for SARS-CoV-2 World Health Organization Diagnostic indexes of a rapid IgG/IgM combined antibody test for SARS-CoV-2 Diagnostic value and dynamic variance of serum antibody in coronavirus disease 2019 Human leukocyte antigen susceptibility map for SARS-CoV-2 Targets of T cell responses to SARS-CoV-2 coronavirus in humans with COVID-19 disease and unexposed individuals Antibodies to coronaviruses are higher in older 15 in identifying coronavirus-associated illnesses Duration of Antibody Responses after Severe Acute Respiratory Syndrome with conventional coronavirus can potentially be falsely labelled as being positive for SARS-CoV-2.This study was approved by ethical committee of Saitama Cardiovascular and Respiratory Center (approval no. 2019055). The authors report no potential conflicts of interest exist with any companies/organisations whose products or services may be discussed in this letter. The authors report no potential conflicts of interest exist with any companies/organisations whose products or services may be discussed in this letter.