key: cord-0002256-vi6rth9o authors: Zhang, Chao; Yao, Yao; Zhu, Juan-Li; Zhang, Si-Nong; Zhang, Shan-Shan; Wei, Hua; Hui, Wen-Li; Cui, Ya-Li title: Establishment and application of a real-time loop-mediated isothermal amplification system for the detection of CYP2C19 polymorphisms date: 2016-06-01 journal: Sci Rep DOI: 10.1038/srep26533 sha: c5df32e01e9583e1b4430418e8f8f58c8a85021c doc_id: 2256 cord_uid: vi6rth9o Single-nucleotide polymorphisms (SNPs) represent the most widespread type of genetic variation (approximately 90%) in the human genome, and the demand to overcome such variation has received more attention now than ever before. The capacity to rapidly assess SNPs that correlate with disease predisposition, drug efficacy and drug toxicity is a key step for the development of personalized medicine. In this work, a rapid one-step SNP detection method, real-time loop-mediated isothermal amplification (RT-LAMP), was first applied for CYP2C19 polymorphisms testing. The optimized method was established with specifically designed primers for target amplification by real-time detection in approximately 30 min under isothermal conditions. RT-LAMP amplified few copies of template to produce significant amounts of product and quantitatively detected human DNA with compatible specificity and sensitivity. The success in the establishment of this RT-LAMP protocol for CYP2C19 polymorphism testing is significant for the extension of this technique for the detection of other SNPs, which will further facilitate the development of personalized medicine. Clinical observations beginning in the 1950s have suggested that individuals exhibit differences in their responses to drugs and that these variations could be inherited 1 . The detection of DNA sequence variations provides valuable insight into the diagnosis of genetic-related diseases and conditions, especially for early-stage treatment and response monitoring 2 . Thus, it is critically important to select a method with high sensitivity and specificity to detect single or small numbers of nucleotide polymorphisms 3, 4 . Current detection methods rely on sample amplification combined with meticulous control, including polymerase chain reaction (PCR), nucleic acid sequence-based amplification (NASBA) 5 , self-sustained sequence replication (3SR) 6 , strand displacement amplification (SDA) 7 and direct sequencing. Although these technologies are currently considered the gold standard for laboratory-based DNA detection and diagnostics, these methods cannot meet the requirements of point-of-care testing (POCT) strategies 8 due to the high set up and operating expenses and the requirements for high-precision equipment. Loop-mediated isothermal amplification (LAMP) is an outstanding gene amplification procedure with high specificity, sensitivity and rapidity that was established by Notomi et al. 9 . The process amplifies nucleic acids under isothermal conditions and employs self-recurring strand-displacement synthesis primed by a specially designed set of target-specific primers 10 , thus clearly distinguishing this technique from existing genetic tests 11 . LAMP is characterized by the use of six specifically designed primer regions to recognize eight regions on the target DNA; thus, the specificity is extremely high 11 . Amplification and detection of a gene can be completed in a one step by incubating the mixture of sample, primers, DNA polymerase with strand displacement activity and substrates under isothermal conditions between 60 and 65 °C. LAMP has been used for the diagnosis of pathogens via the detection of gene segments, e.g., the diagnosis of infectious diseases, such as Japanese encephalitis virus infection 12 , rapid genotyping of carcinogenic human papillomavirus and herpesvirus 12 , and the detection of Middle East Respiratory Syndrome Coronavirus [12] [13] [14] . Numerous investigations have demonstrated that this special identification system is more accurate than PCR-based methods, which use only two primers to recognize two regions. Although detection of human DNA polymorphisms using LAMP is challenging, especially for single-nucleotide polymorphisms (SNPs) due to the complex nature of DNA compared with microbes and viruses 2 , SNPs represent the most widespread type of genetic variation (approximately 90%) in the human genome 15 , and the capacity to rapidly test patients for SNPs that are correlated with disease predisposition, drug metabolism and disease development is a key step for the development of personalized medicine 16 . Thus, the wide application of this simple, rapid and low-cost genotyping LAMP method in SNP detection is imperative. Numerous lines of evidence have strongly suggested that genetic polymorphisms in drug-metabolizing enzymes, transporters, receptors and other drug targets are associated with inter-individual differences in drug treatment response 17 . Sequence variations in drug target proteins, drug-metabolizing enzymes, and drug transporters can alter drug efficacy, drug side effects, or both to cause variable drug responses in individual patients 18 . For example, on March 12, 2010, the US Food and Drug Administration approved a black box warning regarding the diminished effectiveness of clopidogrel in patients who carry two loss-of-function alleles (poor metabolizers) 19 , i.e., CYP2C19*2 (G681A) and CYP2C19*3 (G636A) alleles, which account for 85% and 99% of the nonfunctional alleles in Whites and Asians, respectively 20, 21 . The warning addressed the need for polymorphism genotyping to identify altered clopidogrel metabolism in patients 22 . We developed a rapid, one-step SNP detection method (RT-LAMP) that enables the detection of the CYP2C19 allele in approximately 30 min under isothermal conditions. The optimized RT-LAMP technique is more suitable for point-of-care testing and will further facilitate on-site screening. The successful establishment of an inexpensive, rapid and real-time LAMP protocol for CYP2C19*2 and CYP2C19*3 detection is significant for the extension of this technique for genotyping other SNPs. Our results suggest applications for this RT-LAMP assay system for both basic research and clinical diagnosis in pharmacogenomics. Plasmid construction and identification. In this study, four plasmids were constructed by recombining the specific sequences of CYP2C19*2 G681G, CYP2C19*2 A681A, CYP2C19*3 G636G and CYP2C19*3 A636A. Using the primer pairs *2-seq-F/*2-seq-R and *3-seq-F/*3-seq-R, listed in Table 1 , 226-bp CYP2C19*2 and 450bp CYP2C19*3 fragments were amplified and sequenced by Beijing Genomics Institute (BGI; Beijing, China), indicating the successful incorporation of the four plasmids (data not shown). Based on the point mutations of the CYP2C19*2 (G681A) and CYP2C19*3 (G636A) genes, two sets of RT-LAMP primers were designed to discriminate the SNPs. As shown in Fig. 1 , the basic principle of RT-LAMP involves the use of specific primers, with a forward inner primer (FIP) and backward inner primer (BIP) that are designed to contain a SNP nucleotide at the 5′ terminus, each reaction including two common primers (F3 and B3) and two specific primers (FIP-G and BIP-G for G allele and FIP-A and BIP-A for A allele). The structures of the LAMP primers and products based on this study are presented in Fig. 1 , and the information regarding the primer names and sequences are provided in Table 1 . The target SNP was characterized using six different regions (F1/F1c-F3/F3c and B1/B1c-B3/B3c) specifically designed to recognize distinct regions on the target gene, which were designed to ensure that the primers would specifically amplify the G681A and G636A substitutions. The results depicted in Fig. 2 illustrate that the RT-LAMP method could accurately detect and discriminate all possible homozygotes and heterozygotes of CYP2C19*2 (G681A) and CYP2C19*3 (G636A) SNPs. Sensitivity of the RT-LAMP assay. The sensitivities of the RT-LAMP assay were tested using 10-fold serial dilutions of the four constructed plasmids. The detection limit of the RT-LAMP assay was 1 × 10 1 copies of plasmid (the result for the CYP2C19 G681G plasmid is presented in Fig. 3A ; the results for the other three plasmids are presented in supplementary Fig. S1 ), indicating that the RT-LAMP method was efficient and specific in SNP detection under a constant temperature with greater than 10-fold increased sensitivity compared with conventional PCR 23, 24 . Moreover, as shown in Fig. 3 , a standard curve was generated using 10-fold dilutions of plasmids and calculated by regression analysis comparing the T peek with the copy number. The high correlation coefficient (R 2 = 0.995) indicated that the RT-LAMP assay could be applied in DNA quantification. To test the reliability of the RT-LAMP system optimized in this study, the accuracy of the RT-LAMP assay was further verified using 100 clinical samples. In addition, all of these samples were also assessed via conventional PCR (AS-PCR) and sequenced by BGI. The detected genotypes together with their frequencies are presented in Table 2 . The observed allele frequencies were 75.5%, 24.5%, 95% and 5%, for *2G, *2A, *3G and *3A, respectively (calculated from: *2G: F1 + F3 + F4/2 + F5 + F6/2; *2A: F2 + F4/2 + F6/2; *3G: F1 + F2 + F4 + F5/2 + F6/2; *3A: F3 + F5/2 + F6/2). The frequencies of the CYP2C19*2 and CYP2C19*3 alleles were similar to those reported by Chen et al. 25 in a Chinese population. The comparison of RT-LAMP with AS-PCR and direct sequencing revealed no discrepancies. In recent years, DNA testing technology has been extensively used in the areas of diagnosis and disease detection. The LAMP technique is a unique assay with high efficiency and high accuracy that was developed rapidly. As described in some reports [10] [11] [12] [13] [14] [26] [27] [28] [29] , the LAMP assay has been widely used in the detection of pathogenic microorganisms. However, to the best of our knowledge, reports regarding the detection of mutations in human genomic DNA, especially SNPs, using the LAMP method are lacking. In this study, the successful establishment of an inexpensive, rapid and real-time LAMP protocol for CYP2C19 SNP genotyping expanded the scope of application of this technique to human gene mutation detection. RT-LAMP is a one-step method wherein the amplification itself is the signal for SNP detection, whereas the difficulty in developing this technology involves the suppression of non-specific amplification 30 . To help overcome this difficulty, the target SNP is characterized using six different primer regions specifically designed to recognize eight distinct regions on the target gene 14, 30 . In this work, by adding or subtracting a few nucleotides in the primer regions, the T m value and GC content were calculated until the six different primer regions were suitable for the LAMP reaction. As a result, the primer regions were selected as noted in Fig. 1 (F1-F3 and B1-B3) . Furthermore, as the arrangement and composition of human genomic DNA is very complex, sequence alignment was necessary to avoid false recognition of the specific site. Thus, Primer-BLAST software (http://www.ncbi.nlm. nih.gov/tools/primer-blast) was used to ensure that the chosen primer regions were specific to the target SNP, which helped avoid mismatches and locate the target SNP as accurately as possible. The secondary structures of these primers may cause non-specific results in the LAMP reaction given that the selectable sequence area for primer design is limited to less than four hundred nucleotides surrounding the target SNP site 9 . Hence, the inner primers were designed (Fig. 1) to minimize the impact of the secondary structure given that the inner primers are the main component for DNA strand extension. Moreover, according to Tomita et al., the formation of a starting structure is the key initiating step of LAMP 11 . Specific nucleotides were added to the 5′ termini (5′ -term) of the FIP and BIP primers to establish a complete and effective starting structure, as shown in Fig. 1 . Consequently the starting structure would be successfully established only when the 5′ -term nucleotide was exactly matched with the target SNP (Fig. 1A) . Otherwise, the starting structure was blocked, as shown in Fig. 1C , and the amplification could not proceed. In conclusion, non-specific amplification was effectively suppressed in this work through special primer design and accurate target location. In addition, using real-time fluorescence detection equipment, amplification and detection can be performed in a closed tube, which could reduce the risk of contamination. Thus, the RT-LAMP method that was developed has an excellent sensitivity for detection of CYP2C19 polymorphisms (as shown in Fig. 3A ). Similar results were observed by Singh et al. 23 and Lee et al. 35 with the same sensitivity of 1 × 10 1 copies. Moreover, a standard curve with a high correlation coefficient was obtained in this study, as shown in Fig. 3B , indicating that except for microorganism quantification [32] [33] [34] , the RT-LAMP assay can also be applied in human DNA quantification. Therefore, the RT-LAMP method can be used for the determination of trace amounts of DNA of interest among copious background DNA, such as specific mutation detection in circulating tumour DNA 24, 35 , and can be applied for complex gene quantification, which is clinically meaningful 36, 37 . In summary, as a rapid, feasible and cost-efficient point-of-care (POC) SNP detection method, we demonstrated that RT-LAMP could quantitatively detect human genomic DNA with high specificity and sensitivity in a single step. Moreover, the LAMP method can amplify few copies of template to significant levels in 30 min 11 and can be used for both DNA and RNA targets 38 . Thus, this POC detection method should be helpful in basic research in a variety of fields, including medicine, pharmaceuticals, environmental hygiene, food security, and pharmacogenomics testing. Peripheral blood and genomic DNA extraction. Peripheral blood samples were collected from 100 unrelated Chinese volunteers using EDTA-coated tubes at the Shaanxi Provincial People's Hospital (Xi'an, China) with informed consent. The study was approved by the ethics committee of the National Engineering Research Center for Miniaturized Detection Systems, Xi'an, China. All methods were performed in accordance with these approved guidelines. The genomic DNA from the volunteer was isolated from 200 μ L of blood using a Whole Blood Genomic DNA Isolation Kit (Xi'an GoldMag Nanobiotech Co., Ltd., Xi'an, Shaanxi, China), according to the manufacturer's instructions. The final DNA quality and concentrations were measured using a NanoDrop 2000c/2000 UV-Vis spectrophotometer (Thermo Fisher Scientific, Wilmington, DE, USA), according to the manufacturer's instructions. Primer design and synthesis. For each SNP, six primers for RT-LAMP were designed, including two outer primers (common primers, F3 and B3) and four inner primers (specific primers, FIP-G, FIP-A, BIP-G and BIP-A) that recognize distinct regions of the CYP2C19*2 and CYP2C19*3 alleles (rs4244285 and rs4986893). Conventional PCR primers were designed based on the principle of AS-PCR using the Primer 5.0 software program (Primer-E Ltd., Plymouth, UK). All oligonucleotide primers were synthesized by Invitrogen Biotechnology Ltd. (Shanghai, China). Plasmids for CYP2C19*2 and CYP2C19*3. Plasmids 19-2GG, 19-2AA, 19-3GG and 19-3AA, which contain the CYP2C19*2 G681G, CYP2C19*2 A681A, CYP2C19*3 G636G, and CYP2C19*3 A636A genes, respectively, were constructed using the pMD TM Optimization of RT-LAMP reaction. The initial condition of the RT-LAMP reaction was adopted from Zhang et al. 39 . The LAMP reaction mixtures were incubated for 45 min at 60, 61, 62, 63, 64, or 65 °C to determine RT-LAMP Conventional PCR (n = 100) Total Sequencing (n = 100) Total Agreement (%) Frequency (%) *1/*1 *2/*2 *3/*3 *1/*2 *1/*3 *2/*3 *1/*1 *2/*2 *3/*3 *1/*2 *1/*3 *2/*3 Table 2 . Gene test results and frequency of 200 clinical samples of CYP2C19 alleles (type-specific concordance among RT-LAMP, conventional PCR and direct sequencing). *1/*1: CYP2C19*2 G681G type, CYP2C19*3 G636G type; *2/*2: CYP2C19*2 A681A type, CYP2C19*3 G636G type; *3/*3: CYP2C19*2 G681G type, CYP2C19*3 A636A type, *1/*2: CYP2C19*2 G681A type, CYP2C19*3 G636G type; *1/*3: CYP2C19*2 G681G type, CYP2C19*3 G636A type; *2/*3: CYP2C19*2 G681A type, CYP2C19*3 G636A type. the optimal reaction temperature. Then, the LAMP reaction was performed at the optimal reaction temperature for 15, 30, 45, 60, and 90 min to determine the optimal reaction time ) with the following parameters: one step of 5 min at 95 °C; 32 cycles of 30 s at 95 °C, 30 s at 60 °C, 45 s at 72 °C; and one step of 10 min at 72 °C. All PCR products were detected by electrophoresis on a 2.5% (w/v) agarose gel containing GoldView Nucleic Acid Stain (an alternative to ethidium bromide, Xi'an Heart Biological Technology Co., Ltd For the samples to be sequenced, a 226-bp fragment for CYP2C19*2 and a 450-bp fragment for CYP2C19*3 were amplified using sequencing primers (Table 1). The PCR products were sequenced by the Beijing Genomic Institute Sensitivity of RT-LAMP assay. The sensitivities were assessed using the optimized RT-LAMP assay with Pharmacogenomics-drug disposition, drug targets, and side effects DNA diagnostics: nanotechnology-enhanced electrochemical detection of nucleic acids Array-based DNA diagnostics: let the revolution begin A nanoliter fluidic platform for large-scale single nucleotide polymorphism genotyping Isothermal nucleic acid amplification technologies for point-of-care diagnostics: a critical review Enzyme-free amplified detection of nucleic acids based on self-sustained replication of RNAzyme and its application in tumor cell detection Isothermal strand displacement amplification (iSDA): a rapid and sensitive method of nucleic acid amplification for point-of-care diagnosis Genotyping single nucleotide polymorphisms by MALDI mass spectrometry in clinical applications Loop-mediated isothermal amplification of DNA Development and application of loop-mediated isothermal amplification for detection of the F167Y mutation of carbendazim-resistant isolates in Fusarium graminearum Loop-mediated isothermal amplification (LAMP) of gene sequences and simple visual detection of products Loop-mediated isothermal amplification (LAMP): recent progress in research and development Real-time sequence-validated loop-mediated isothermal amplification assays for detection of Middle East Respiratory Syndrome Coronavirus (MERS-CoV) Loop-mediated isothermal amplification (LAMP): principle, features, and future prospects The utility of single nucleotide polymorphisms in inferences of population history Rapid SNP diagnostics using asymmetric isothermal amplification and a new mismatch-suppression technology Rapid and cost-effective SNP detection method: application of SmartAmp2 to pharmacogenomics research Pharmacogenomics and individualized medicine: translating science into practice Sanofi Pharmaceuticals Partnership. Plavix (clopidogrel bisulfate) Genetic polymorphism of cytochrome P450 2C19 in Mexican Americans: A cross-ethnic comparative study Effects of CYP2C19 genotype on outcomes of clopidogrel treatment ACCF/AHA clopidogrel clinical alert: approaches to the FDA "boxed warning": a report of the American College of Cardiology Foundation Task Force on clinical expert consensus documents and the American Heart Association endorsed by the Society for Cardiovascular Angiography and Interventions and the Society of Thoracic Surgeons Loop-mediated isothermal amplification targeting insect resistant and herbicide tolerant transgenes: Monitoring for GM contamination in supply chain Circulating tumor DNA as a liquid biopsy for cancer Genetic polymorphism analysis of CYP2C19 in Chinese Han populations from different geographic areas of mainland China Real-time loop-mediated isothermal amplification (RealAmp) for the species-specific identification of Plasmodium vivax Real-time fluorescence loop mediated isothermal amplification for the diagnosis of malaria Real-time loop-mediated isothermal amplification (LAMP) assay for group specific detection of important trichothecene producing Fusarium species in wheat Detection of Middle East respiratory syndrome coronavirus using reverse transcription loop-mediated isothermal amplification (RT-LAMP) Development of an electrochemical method for Ochratoxin A detection based on aptamer and loop-mediated isothermal amplification Clinical evaluation of a loop-mediated isothermal amplification (LAMP) assay for rapid detection of neisseria meningitidis in Cerebrospinal Fluid Loop-mediated isothermal amplification of DNA (LAMP): A new diagnostic tool lights the world of diagnosis of animal and human pathogens: A review Application of ethidium bromide monoazide for quantification of viable and dead cells of Salmonella enterica by real-time loop-mediated isothermal amplification Rapid real-time loop-mediated isothermal amplification combined with coated activated carbon for detection of low numbers of Salmonella enterica from lettuce without enrichment Clinical validation of the detection of KRAS and BRAF mutations from circulating tumor DNA Simultaneous quantification of mitochondrial DNA copy number and deletion ratio: A multiplex real-time PCR assay Comparison of four digital PCR platforms for accurate quantification of DNA copy number of a certified plasmid DNA reference material Innate reverse transcriptase activity of DNA polymerase for isothermal RNA direct detection Determination of ABO blood group genotypes using the real-time loop-mediated isothermal amplification method This work was funded by the National Science and Technology Major Projects for "Major New Drugs Innovation and Development" of China (NOS. 2012ZX09506001-001) and Northwest University Graduate Innovation and Creativity Funds (NOS. YZZ15008).