key: cord-0020474-binop7m0 authors: Pierantoni, Maria; Silva Barreto, Isabella; Hammerman, Malin; Verhoeven, Lissa; Törnquist, Elin; Novak, Vladimir; Mokso, Rajmund; Eliasson, Pernilla; Isaksson, Hanna title: A quality optimization approach to image Achilles tendon microstructure by phase-contrast enhanced synchrotron micro-tomography date: 2021-08-27 journal: Sci Rep DOI: 10.1038/s41598-021-96589-w sha: da142c9c0cd6a86d4a33909b22dae716f905ef5f doc_id: 20474 cord_uid: binop7m0 Achilles tendons are mechanosensitive, and their complex hierarchical structure is in part the result of the mechanical stimulation conveyed by the muscles. To fully understand how their microstructure responds to mechanical loading a non-invasive approach for 3D high resolution imaging suitable for soft tissue is required. Here we propose a protocol that can capture the complex 3D organization of the Achilles tendon microstructure, using phase-contrast enhanced synchrotron micro-tomography (SR-PhC-μCT). We investigate the effects that sample preparation and imaging conditions have on the resulting image quality, by considering four types of sample preparations and two imaging setups (sub-micrometric and micrometric final pixel sizes). The image quality is assessed using four quantitative parameters. The results show that for studying tendon collagen fibers, conventional invasive sample preparations such as fixation and embedding are not necessary or advantageous. Instead, fresh frozen samples result in high-quality images that capture the complex 3D organization of tendon fibers in conditions as close as possible to natural. The comprehensive nature of this innovative study by SR-PhC-μCT breaks ground for future studies of soft complex biological tissue in 3D with high resolution in close to natural conditions, which could be further used for in situ characterization of how soft tissue responds to mechanical stimuli on a microscopic level. www.nature.com/scientificreports/ beamline (Fig. 1B) . The tubes were oriented such that the bone junction was up, and the muscles were down. The paraffin blocks were glued to the stage holder using hot glue. Phase contrast enhanced synchrotron X-ray micro-tomography (SR-PhC-μCT). The experiment was carried out at the X02DA TOMCAT beamline at the Swiss Light Source (SLS), Paul Scherrer Institute (Villigen, Switzerland) 47 . The tomographic setup was optimized to acquire phase contrast images for single distance phase retrieval. As the pixel size δ is given by the details to be resolved in the sample, the X-ray wavelength, λ by sample transmission, the sample to detector distance (z D ) remains to be optimized. An initial value is typically given by the size of the first interference fringe as z D = (2δ) 2 /λ. This parameter was optimized for each one of the two optical microscope setups for X-ray to visible light conversion that were used. The two optical microscope setups were (Fig. 1C ). -High Numerical Aperture Microscope (HNAM) (custom made objective, optiquepeter.com), 4× magnification, field of view (FOV) of 4.2 mm × 3.5 mm and final voxel size of 1.63 µm × 1.63 µm × 1.63 µm). The optical setup was coupled to a LuAG:Ce scintillator screen of 150 μm. The optical setup was coupled to a LuAG:Ce scintillator screen of 150 μm. For HNAM, the theoretically maximal value of the sample to detector distance to fulfil the single distance phase retrieval would be ~ 130 mm. However, our optimization procedure converged to a larger distance of 150 mm for which we achieved the best compromise between contrast and resolution after tomographic reconstruction. To visualize the subtle contrast between the fibers and the matrix the X-ray energy was set at 15 keV at which the X-ray matter interaction in our system was sufficiently strong but still allowed transmission (20-40%) through the sample. 2001 projections were acquired over 180° of continuous rotation. Projections were collected by a pco.edge 5.5 Camera (detector sCMOS sensor of 2560 × 2160 pixels, 6.5 μm pixel size and a 16-bit nominal dynamic range). The exposure time was 33 ms resulting in about 90 s scans and the skin dose for a single projection about 6 Gy. The HNAM setup was used to assess all four sample preparation protocols to investigate their effect. -High resolution microscope (HRM) (objective UPLAPO20x, 20× magnification, FOV of 0.7 mm × 0.8 mm and final voxel size 0.33 µm × 0.33 µm × 0.33 µm). HRM was coupled to a LuAG:Ce scintillator screen of 20 μm. For HRM, the theoretical sample to detector distance would be ~ 5 mm. As for HNAM, our optimization resulted again in a larger value of 54 mm. This time the difference to the theoretical value is rather large, in part due to the fact that the true resolution of this optical setup is coarser than 2δ. The beam energy was set to 15 keV, and 4001 projections were acquired over 360° continuous rotation. Projections were collected by a pco.edge 5.5 Camera (detector sCMOS sensor of 2560 × 2160 pixels, 6.5 μm pixel size and a 16-bit nominal dynamic range). The exposure time was 100 ms, resulting in about 8 min scans. We calculated the skin dose rate to be 200 Gy/s 48 therefore during a single radiographic projection the skin dose at the sample is 20 Gy. The actual dose which the sample receives is www.nature.com/scientificreports/ smaller due to its finite size, but the skin dose is a good measure of the upper limit. This setup was used to test how an increase of magnification would affect the image quality, and fresh frozen samples in PBS and samples fixed in ethanol were imaged. Imaging and volume reconstructions. All samples were imaged with HNAM in consecutive locations from the muscles to the bone moving the FOV vertically 3 mm each time, this allowed to image the tendon from the muscle junction to the bone junction ( Fig. 2A) . Three fresh and three fixed samples were also imaged with HRM. In this case, the tendon was imaged with 4-6 consecutive vertical scans from the muscles to the bone moving the FOV vertically 0.6 mm each time. All projections were corrected with dark and flat-field images. The projected density of the sample was calculated using the Paganin phase retrieval for homogeneous objects 49 . The tomographic reconstruction was performed using a Fourier based regridding algorithm 50 . We used the following procedure to optimize the ratio of δ:β required for the reconstructions: a) the absorption coefficient β = 9.3 × 10 -9 was determined for tendon tissue using the X-ray mass attenuation coefficients and density for soft tissues (ICRU-44) according to the NIST database 51 . b) The refractive index decrement δ was varied between 10:1, 50:1 and 100:1, by increasing the contribution of the phase retrieval. c) The intensity profile over 200 pixels was determined on the same location. Based on the intensity profile reconstructions were performed using a ratio of 50:1 ( Supplementary Fig. S1 ). In fact, the interference fringe is visible when using a 10:1 ratio ( Supplementary Fig. S1A ). When using a 100:1 ratio, the small features are lost ( Supplementary Fig. S1C ). Finally, using a 50:1 ratio it is still possible to distinguish all features, but the fringe is filtered ( Supplementary Fig. S1B ). For each microscope setup all data were reconstructed using the same gray scale intervals. Image quality analysis. Each volume was reoriented in ImageJ 52 , so that the tendon main axis was parallel www.nature.com/scientificreports/ evaluate image sharpness (Fig. 2D ). Four main properties ( Fig. 1E -H) were calculated to determine the images quality using custom made MATLAB scripts. -Spatial resolution The resolution was determined using a criterion based on the Power spectrum (Fourier domain) analysis 54 . This method reflects similar image properties (noise content) as the Fourier Shell Correlation approach which is also often used in tomography. Line profiles were taken in x and y directions (see coordinate system in Fig. 2C ) and the power spectral density was calculated as described by Lovric et al. 55 . From the fiber sub-volumes, three slices along the z direction were considered, at the top, in the middle and at the end of the sub-volume. The spectral density converged at the level of the noise. The final spatial resolution was obtained by considering twice the value at converge and by coupling it to the respective spatial frequency. -Fiber-to-matrix contrast ratio (FMCR) By considering the fibers as the material of interest and the matrix around them as the background, the FMCR corresponds to the contrast-to-noise ratio (Fig. 1F) . It was calculated as described by Saccomano et al. and Lovric et al. 21, 55 , using the following equation: where Im is the mean voxel value and σ is the standard deviation for fibers and matrix, respectively. -Uncertainty of the threshold-based segmentation of fibers and matrix (UTS) For the exploitation of images in terms of the scientific results perhaps the most important measure of image quality is how reliably one can segment the structure of interest from the images. It is not easy to express this reliability. We proposed to quantify the relative number of voxels with gray scale values which did not allow to systematically differentiate if they belonged to the fiber or the matrix phase ( Supplementary Fig. S2A ). To calculate the UTS, we found the threshold value for which the fibers are selected as precisely as possible and the value to precisely select the matrix. To minimize bias, the value was selected using the Otsu's method. The images obtained with HNAM were first Gaussian filtered before assessing the threshold value ( Supplementary Fig. S2B ), whereas the filtering was not required for images obtained with HRM (the same threshold value was found with and without filtering). The UTS values represent the quantity of voxels that cannot be uniquely assigned to the fiber or the matrix phase and are here presented as a percentage of the total number of pixels. -Gradient sharpness at the edges (GSE) To quantify the sharpness at the edges, or inversely the blurriness, the maximum rate of change at each edge point was considered, which was given by the magnitude of the gradient ( Supplementary Fig. S3 ). The GSE is the average edge gradient magnitude value normalized to the number of edge points. GSE was calculated from the sub-volumes containing only fat cells (Fig. 2D ), primarily because the fat spheres have clear and sharp borders. Furthermore, the transition to the inter-fibre matrix can sometimes be unclear, which would induce large variability in the data. Reproducibility. All analyses to determine image quality (Fig. 1I) were repeated in different sub-volumes of each sample moving along the tendon main axis three times for fixed and fresh samples and two times in embedded samples (sample shrinkage and cracks in the tissue reduced the volume available for the analysis). Cross-sectional area. To quantify the level of tissue dehydration after fixation and embedding, the average cross-sectional area was calculated for the central ~ 500 µm of the tendons using MATLAB. The region was chosen in the middle of the tendon (equal distance from both bone and muscle) where the shape of the cross-section was the most consistent. However, it should be noted that even in the center of the sample the cross section can slightly change along the tendon length and fat is irregularly deposited along the outer sample. As the tendon tissue was not distinguishable from the background by contrast threshold (Supplementary Fig. S4A ), the tendon cross section was selected after increasing the tissue contrast by projecting the maximum intensity at every 100 slices ( Supplementary Fig. S4B ). The contrast-enhanced cross section was binarized and the area was calculated ( Supplementary Fig. S4C ). Achilles tendons were harvested and incubated in the following solutions: 15% sucrose (Sigma Group, Malmö, Sverige, S0389) at 4 °C overnight, 30% sucrose at 4 °C overnight, a 1:1 mixture of optimal cutting temperature compound (OCT; VWR International AB, Spånga, Sweden, 00411243) and 30% sucrose for 20 min. They were then placed in 100% OCT, snap-frozen and stored at − 80 °C until sectioning. The tendons were sectioned longitudinally (7 µm thickness) comprising the full length of the tendon. One slide of each specimen was stained with hematoxylin and eosin and examined using an Olympus BX51 light microscope. The other slide was used for immunohistochemistry staining for collagen type 1 as follows. Directly after sectioning a blocking buffer containing 5% normal goat serum (Sigma Group, Malmö, Sverige; G9023) was added for 2 h. Primary polyclonal antibodies from rabbit were used ( www.nature.com/scientificreports/ 62248) for 3 min and then mounted with ProLong gold antifade reagent (Thermo Fisher Scientific, Stockholm Sweden; P36930). The stained specimens were examined using a Lecia DMi8 microscope (Leica Microsystems, Wetzlar, Germany). The fluorescence was detected at 550 nm (collagen 1) and 385 nm (DAPI). The images were taken with a Hamamatsu Orca LT Flash sCMOS camera. The images were adjusted to the negative control staining, where the primary antibody was omitted, to correct for unspecific antibody detection. Kidney from rat was used as a positive control. As this represents one of the first studies in which the tendon microstructure was imaged by phase contrast enhanced synchrotron tomography, we compared the tomographic data to state of the art histology to show that the internal tendon structure presents as expected (Fig. 3) . The effects of sample preparation. In the case of fresh frozen samples in PBS, fixed samples, and embedded tendons the internal fiber structure was visually distinguishable, and no image artifacts were clearly observed (Fig. 4) . Only in the case of the fresh samples in glycerol, the contrast was reduced substantially by the medium so that the fibers were not visible and ring artefacts were clearly distinguishable (Fig. 4B,F,J) . The fibers ran parallel along the tendon main longitudinal axes, and were tightly packed with only limited matrix being visible in between (Fig. 4) . Furthermore, except for those immersed in glycerol, all sample preparations were suitable to study the tendon-bone and tendon-muscle junctions (Fig. 5A,B) . As fibers closely intercalate into the muscular tissue, they presented a more crimped conformation than in the center of the tendon (Fig. 5A vs Fig. 4E,G,H) . At the bone junction, the merging of the tendon into the bone was characterized by a sharp transition (Fig. 5B) . In fixed and embedded samples, cracks formed in the tissue (Supplementary Fig. S5 ) and the tendons shrank due to dehydration. In the central region of the tendons the average area of fresh samples in PBS was 1.39 ± 0.48 mm 2 , whereas for fixed samples and embedded samples the average areas were 1.02 ± 0.02 mm 2 and 0.54 ± 0.40 mm 2 , respectively, indicating ~ 40% and ~ 60% reductions when compared to fresh samples. Fresh samples preserved a more pristine structure with cells being visible between the fibers (Fig. 3E,F, Supplementary video S2) . www.nature.com/scientificreports/ Image quality. For fresh samples in glycerol, the image quality analysis was not conducted as it was not possible to distinguish the tendon internal structure due to e.g. low contrast and substantial ring artefacts. However, for the rest of the samples the resolution was only slightly affected by the type of preparation. The average resolutions were: 5.0 ± 0.1 µm (coefficient of variability, CV = 0.03), 4.9 ± 0.3 µm (CV = 0.06) and 5.3 ± 0.4 µm (CV = 0.08), for fresh, fixed, and embedded samples respectively (Fig. 6A) . Differently from the resolution, the FMCR was affected by the sample preparation, where higher values correspond to better image quality. The FMCR was the highest for fixed samples and the lowest for embedded samples. The average FMCRs were 1.4 ± 0.1, 1.9 ± 0.2 and 0.7 ± 0.1 respectively for fresh, fixed, and embedded samples (Fig. 6B) . The variability within the preparation groups was below 10% (CV ≤ 0.1 for all groups). The results further indicate that the segmentation uncertainty was comparable for fixed and embedded samples and slightly higher in the case of fresh samples (average UTS: 1.5 ± 0.6, 0.9 ± 0.5 and 1.1 ± 0.5 respectively for fresh, fixed, and embedded samples, Fig. 6C ). However, for UTS there was a considerable variability between samples from the same preparation group (CV = 0.4, CV = 0.5, CV = 0.4 for fresh, fixed, and embedded samples respectively). The data showed that the edges were the least sharp (i.e. low GSE values) in the embedded samples and comparable for fresh and fixed samples (average GSE: 1.65 ± 0.36, 1.54 ± 0.44 and 0.94 ± 0.18 for fresh, fixed, and embedded samples respectively, Fig. 6D ). Also for GSE, the intragroup differences were quite pronounced (CV = 0.3, CV = 0.2, CV = 0.2 respectively for fresh, fixed, and embedded samples). The four parameter values were consistent between subvolumes of the same group ( Supplementary Fig. S6 ). The effect of the imaging setup. By an initial visual inspection fiber contours were similarly distinguishable in images acquired by HNAM and HRM with no pronounced differences (Fig. 7) . Imagining at five times higher magnification (HRM setup), the spatial resolution (1.2 ± 0.3 µm) was four times lower than for HNAM (4.6 ± 0.3 µm) (Fig. 6A vs Fig. 8A ). The FMCR was higher for HRM compared to HNAM acquisitions, but not proportional to the increase in magnification. The contrast ratio was comparable for the two sample preparations (average FMCR: 3.4 ± 0.1 and 3.6 ± 1.2 for fresh and fixed samples, respectively, Fig. 8B ). Imagining at five times higher magnification did not translate into a lower level of segmentation uncertainty (average UTS: 1.9 ± 0.9 and 1.3 ± 1.2 for fresh and fixed samples, respectively, Fig. 8C) . Furthermore, the GSE did not substantially increase when HRM scans were considered (average GSE: 1.27 ± 0.35 and 1.11 ± 0.5 for fresh and fixed samples, Fig. 8D ). This work provides a comprehensive description of the Achilles tendon structure using phase-contrast enhanced synchrotron micro-tomography. Acquiring 3D high-quality images is fundamental to study complex biological structure and to enable precise segmentation of the structures of interest. Four types of sample preparations and two imaging setups were evaluated and compared. Fresh frozen, fixed, and embedded tissue enabled visualization of the tendon internal structure (Fig. 4) . As imaging artefacts due to sample movements were reported previously for fresh frozen intervertebral disk samples 33 , we also investigated if a more viscous solution, such as glycerol, could help reduce possible micro-vibrations. However, this drastically reduced the image quality (Fig. 4B,F,J) , resulting in the conclusion that glycerol solution is not suitable to study the tendon microstructure. The three other types of sample preparations were found suitable for the visualization of the tendon microstructure and junctions (Fig. 5A,B) . Junctions are of considerable biological relevance since an understanding of how the tendon intercalates into the muscle and connects to the calcaneus bone could help rationalize how mechanical loading is transferred. www.nature.com/scientificreports/ Our quantitative approach to determine the image quality showed that the spatial resolution was not substantially affected by the type of sample preparation (Fig. 6A) . The level of precision of the segmentation of the fibers from the matrix was estimated by calculating FMCR and UTS. The FMCR was the highest for fixed samples and the lowest for embedded samples (Fig. 6B) . We hypothesize that the increased contrast of the fixed samples compared to the fresh samples could be a consequence of the dehydration of the matrix due to fixation. Whereas, in the case of the embedded samples the lower FMCR could be attributed to high standard deviation as a consequence of apparent gray-value fluctuations as individual fibers are nearly resolved inside the bundles (Fig. 4L) . Furthermore, due to sample dehydration, fibers did to some extent shrunk and more borders between adjacent fibers were visible compared with other sample preparations. In order to cover statistically relevant number of voxels the regions for FMCR calculations comprise often more than one fiber. An increased contrast between individual fibers therefore lowers the FMCR between interfascicular matrix and regions attributed to fibers (fiber bundles). Lovric et al. found that a contrast to noise ratio (FMCR in our case) of 2 was the lower limit for an effective segmentation of lung tissue 55 . We expected a similar limit to be sufficient to enable the segmentation of Achilles tendon fibers from the matrix, and this limit value was almost reached (for fixed samples, FTMCR = 1.9 ± 0.2). Furthermore, the uncertainty of the threshold segmentation was in all cases below 2.5% (Fig. 6B,C) . Together these two factors indicated that the fibers could be distinguished from the matrix rather successfully for all sample preparations. However, further image processing could still improve the ability to segment the collagen fibers. In summary, the four considered properties showed similar trends for image quality, where lower resolution limit and UTS were associated with higher FMCR and GSE. Furthermore, the Fig. S7 ). Lower quality images for embedded samples were also previously observed in the case of intervertebral disks 33 . However, it should be noted that for intervertebral disks the final image quality was further reduced by the presence of cracks in the paraffin blocks which were not observed in the embedded tendons. Even though individual tendon fibers are harder to distinguish than when the sample undergoes cell maceration 40 , the fact that the imaging of fresh frozen samples in PBS solution resulted in high image quality is of great importance since this preparation allows visualizing the tendon structure as close as possible to the native conditions. This breaks ground for future research to study the relation between mechanical stimuli and structural response which would have not been possible in the case of more invasive sample preparations. In the future, the mechanical response of frozen-preserved samples could be studied by performing mechanical loading concurrently with synchrotron imaging (which has previously been done for e.g. bones on different length scales [56] [57] [58] ). This would allow to directly determine how different fibers behave under mechanical stimulation. Furthermore, cells between fibers were visible (Fig. 3E,F) . The morphologies and sizes of the observed cells strongly resembled the ones of cells shown in the histological slices (Fig. 3A,B ) and the ones previously presented in other histological studies of tendons 11 . Tendon cells are responsible for synthesis and turnover of the collagen fibers and they respond to the local mechanical environment 59, 60 . Consequently, to understand the relation between tendon structure and mechanical stimuli, the possibility of visualizing tendon cells in conditions close to native is significant. In addition to the advantages of studying a tissue in conditions close to native, when Fig. S5 ). The shrinkage of soft tissue caused by the dehydration process is a well-documented phenomenon which occurs due to the tissue processing steps during standard fixation and is not unique to Achilles tendons 41, 61, 62 . After concluding that fresh and fixed samples showed similar image quality, we further investigated for these two sample preparations, if an increase in magnification would translate to a significant increase in image quality. The five times higher magnification setup (HRM) resulted in images with improved resolution and FMCR (Fig. 8A,B) . The UTS and the GSE were not necessarily improved by the higher magnification, probably due to the presence of small regions with high noise levels (Fig. 8C,D) . The four times improvement in resolution was substantial. However, the higher magnification comes with the drawback of more than six times higher radiation exposure. Accordingly, imaging Achilles tendons using the higher magnification setup could be advantageous for structural characterization. However, the HNAM setup seems more suitable for possible future studies of the relation between structure and mechanical loading, which requires well preserved tissue and careful planning to limit radiation dose [63] [64] [65] [66] . Despite the comprehensive design of the study, some limitations still exist. For instance, studying fresh samples, that had not earlier been frozen, would guarantee imaging the tissue in condition even closer to native. www.nature.com/scientificreports/ However, in our case it was not possible to scan the samples immediately after tendon dissection as the animal experiment and the synchrotron imaging were conducted in different countries. PBS and glycerol are widely used buffer solutions that help preserve samples and do not cause cell damage. However, they also do not chemically fix the samples. Therefore, the samples had to be frozen until just prior to the imaging to prevent degradation of the tissue. Furthermore, we did not consider imaging stained samples by laboratory X-ray tomography, which was previously proven successful for ligaments 67 . However, previous studies have also shown that, for similar types of non-mineralized biological samples, stain solutions such as PMA and PTA often do not fully penetrate the tissue [68] [69] [70] . Furthermore, even when the solutions penetrate (e.g. Logol's iodine), the stained tissue does not always show more internal details or improved resolution compared to the unstained tissue 21, 33 . Finally, for other types of biological samples such as muscle and heart tissues, recent methodological advances demonstrated that laboratory phase-contrast microtomography may in the future be implemented also for other types of soft tissues such as tendons 71, 72 . This work demonstrates that SR-PhC-μCT imaging of fresh frozen Achilles tendons can provide a comprehensive anatomical understanding of the complex internal structure without invasive sample preparations. In Achilles tendons, structure and mechanical performance are strongly interconnected. Consequently, the possibility of studying samples in conditions close to their native state is of great relevance in the perspective of understanding the tendon microstructural response to mechanical loading. The results of this study and the proposed method to quantify image quality could be of use in future studies of other soft collagen based biological tissues (such as lungs, heart, and meniscus). Received: 15 January 2021; Accepted: 6 August 2021 Tendon injuries The multicomposite structure of tendon Mechanobiology of tendon Collagen structure of tendon relates to function Specialization of tendon mechanical properties results from interfascicular differences Helical sub-structures in energy-storing tendons provide a possible mechanism for efficient energy storage and return Human tendon adaptation in response to mechanical loading: A systematic review and meta-analysis of exercise intervention studies on healthy adults The effect of muscle paralysis using Botox on the healing of tendon to bone in a rat model Achilles tendon compositional and structural properties are altered after unloading by botox Different achilles tendon pathologies show distinct histological and molecular characteristics Novel procedure for high-fidelity tendon histology Limitations of clinical and biological histology Showing their true colors: A practical approach to volume rendering from serial sections Fusion of histological sections and MR images: Towards the construction of an atlas of the Human Basal Ganglia Evidence of structurally continuous collagen fibrils in tendons Second harmonic generation confocal microscopy of collagen type I from rat tendon cryosections Tendon response to matrix unloading is determined by the patho-physiological niche Quantitative characterization of the achilles tendon in cadaveric specimens: T1 and T2* measurements using ultrashort-TE MRI at 3 T. Am Ultrasound detection of heel enthesitis: A comparison with magnetic resonance imaging Tendon structure, disease, and imaging. Muscles Ligaments Tendons J Synchrotron inline phase contrast µCT enables detailed virtual histology of embedded soft-tissue samples with and without staining X-ray computed microtomography (μCT) using synchrotron radiation (SR) Phase-contrast X-ray computed tomography for observing biological soft tissues On the possibilities of X-ray phase contrast microimaging by coherent high-energy synchrotron radiation Phase-contrast imaging of weakly absorbing materials using hard X-rays The projection approximation and edge contrast for X-ray propagation-based phase contrast imaging of a cylindrical edge Holotomography: Quantitative phase tomography with micrometer resolution using hard synchrotron radiation X-rays Whole heart detailed and quantitative anatomy, myofibre structure and vasculature from X-ray phasecontrast synchrotron radiation-based micro computed tomography Cartilage and soft tissue imaging using X-rays: Propagation-based phase-contrast computed tomography of the human knee in comparison with clinical imaging techniques and histology Characterization of osteoarthritic and normal human patella cartilage by computed tomography X-ray phase-contrast imaging: A feasibility study Three-dimensional characterization of the microstructure in rabbit patella-patellar tendon interface using propagation phase-contrast synchrotron radiation microtomography X-ray phase contrast imaging of the bone-cartilage interface Visualising the 3D microstructure of stained and native intervertebral discs using X-ray microtomography Synchrotron radiation X-ray phase-contrast tomography visualizes microvasculature changes in mice brains after ischemic injury High-resolution visualization of airspace structures in intact mice via synchrotron phase-contrast X-ray imaging (PCXI) Visualization and stereological characterization of individual rat lung acini by high-resolution X-ray tomographic microscopy 3D virtual pathohistology of lung tissue from COVID-19 patients based on phase contrast X-ray tomography Visualizing treatment delivery and deposition in mouse lungs using in vivo X-ray imaging Multiscale X-ray phase contrast imaging of human cartilage for investigating osteoarthritis formation Tracking tendon fibers to their insertion-A 3D analysis of the Achilles tendon enthesis in mice Comparative analysis of sample preparation protocols of soft biological tissues for morphometric studies using synchrotron-based X-ray microtomography High-contrast X-ray micro-radiography and micro-CT of ex-vivo soft tissue murine organs utilizing ethanol fixation and large area photon-counting detector Phase-contrast hounsfield units of fixated and non-fixated soft-tissue samples Phase-contrast X-ray tomography of neuronal tissue at laboratory sources with submicron resolution Contrast enhancement for visualizing neuronal cytoarchitecture by propagationbased X-ray phase-contrast tomography Image quality comparison between a phase-contrast synchrotron radiation breast CT and a clinical breast CT: A phantom based study Trends in synchrotron-based tomographic imaging: the SLS experience A multi-purpose imaging endstation for high-resolution micrometerscaled sub-second tomography Simultaneous phase and amplitude extraction from a single defocused image of a homogeneous object Regridding reconstruction algorithm for real-time tomographic imaging NIST Chemistry Webbook ImageJ for the next generation of scientific image data Spatial resolution in Bragg-magnified X-ray images as determined by Fourier analysis Dose optimization approach to fast X-ray microtomography of the lung alveoli Investigating the mechanical characteristics of bone-metal implant interface using in situ synchrotron tomographic imaging Sub-trabecular strain evolution in human trabecular bone Linking multiscale deformation to microstructure in cortical bone using in situ loading, digital image correlation and synchrotron X-ray scattering Effects of exercise on the biomechanical, biochemical and structural properties of tendons Role of extracellular matrix in adaptation of tendon and skeletal muscle to mechanical loading Going beyond histology. Synchrotron micro-computed tomography as a methodology for biological tissue characterization: From tissue morphology to individual cells Three dimensional imaging of paraffin embedded human lung tissue samples by micro-computed tomography Clinical doses of radiation reduce collagen matrix stiffness Effect of X-ray irradiation on articular cartilage mechanical properties Early effects of ionizing radiation on the collagen hierarchical structure of bladder and rectum visualized by atomic force microscopy Effects of ex vivo ionizing radiation on collagen structure and whole-bone mechanical properties of mouse vertebrae X-ray computed tomography of the anterior cruciate ligament and patellar tendon Soft tissue discrimination with contrast agents using micro-CT scanning An exploratory study of contrast agents for soft tissue visualization by means of high resolution X-ray computed tomography imaging Optimal contrast agent staining of ligaments and tendons for X-ray computed tomography Fiber orientation in a whole mouse heart reconstructed by laboratory phase-contrast micro-CT X-ray phase-contrast tomography for high-spatial-resolution zebrafish muscle imaging Funding from the Knut and Alice Wallenberg KAW Foundation (Wallenberg Academy Fellows 2017.0221) and the Carl Trygger Foundation (18:166) are greatly acknowledged. VN acknowledges funding from the European Union's Horizon 2020 research and innovation program under the Marie Skłodowska-Curie Grant Agreement No. 701647. We acknowledge the Paul Scherrer Institut, Villigen, Switzerland for provision of synchrotron radiation beamtime at the TOMCAT beamline X02DA of the SLS. Open access funding provided by Lund University. The authors declare no competing interests. The online version contains supplementary material available at https:// doi. org/ 10. 1038/ s41598-021-96589-w.Correspondence and requests for materials should be addressed to M.P.Reprints and permissions information is available at www.nature.com/reprints.Publisher's note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations. License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http:// creat iveco mmons. org/ licen ses/ by/4. 0/.