key: cord-0684791-bw43bsis authors: Perkmann, Thomas; Mucher, Patrick; Perkmann-Nagele, Nicole; Radakovics, Astrid; Repl, Manuela; Koller, Thomas; Schmetterer, Klaus G.; Bigenzahn, Johannes W.; Leitner, Florentina; Jordakieva, Galateja; Wagner, Oswald F.; Binder, Christoph J.; Haslacher, Helmuth title: The Comparability of Anti-Spike SARS-CoV-2 Antibody Tests is Time-Dependent: a Prospective Observational Study date: 2022-02-23 journal: Microbiol Spectr DOI: 10.1128/spectrum.01402-21 sha: 00e8389d27157c33bb31f2910b5ac85dee081368 doc_id: 684791 cord_uid: bw43bsis Various commercial anti-Spike SARS-CoV-2 antibody tests are used for studies and in clinical settings after vaccination. An international standard for SARS-CoV-2 antibodies has been established to achieve comparability of such tests, allowing conversions to BAU/mL. This study aimed to investigate the comparability of antibody tests regarding the timing of blood collection after vaccination. For this prospective observational study, antibody levels of 50 participants with homologous AZD1222 vaccination were evaluated at 3 and 11 weeks after the first dose and 3 weeks after the second dose using two commercial anti-Spike binding antibody assays (Roche and Abbott) and a surrogate neutralization assay. The correlation between Roche and Abbott changed significantly depending on the time point studied. Although Abbott provided values three times higher than Roche 3 weeks after the first dose, the values for Roche were twice as high as for Abbott 11 weeks after the first dose and 5 to 6 times higher at 3 weeks after the second dose. The comparability of quantitative anti-Spike SARS-CoV-2 antibody tests was highly dependent on the timing of blood collection after vaccination. Therefore, standardization of the timing of blood collection might be necessary for the comparability of different quantitative SARS-COV-2 antibody assays. IMPORTANCE This work showed that the comparability of apparently standardized SARS-CoV-2 antibody assays (Roche, Abbott; both given in BAU/mL) after vaccination depends on the time of blood withdrawal. Initially (3 weeks after the first dose AZD1222), there were 3 times higher values in the Abbott assay, but this relationship inversed before boosting (11 weeks after the first dose) with Roche 2 times greater than Abbott. After the booster, Roche quantified ca. 5 times higher levels than Abbott. This must be considered by clinicians when interpreting SARS-CoV-2 antibody levels. specific antibodies elicited by an infection or vaccine (3) . Thus, SARS-CoV-2 antibody tests can be used to confirm known prior infections or detect unreported infections in seroprevalence surveys (4, 5) . For this purpose, different antigens are used, which can be divided into two classes: SARS-CoV-2 nucleocapsid-specific antibodies and antibodies directed against the spike protein (6) . The latter antibodies, which are formed against components of the virus surface spike protein, are induced by all COVID vaccines currently in use, making them an ideal surrogate for the immune response after vaccination (7) . The need to develop quantitative assays to detect vaccine-induced antibodies was highlighted early in the pandemic. Quantitative detection of antibodies was considered an essential requirement to perform immunogenicity and efficacy studies and eventually to establish thresholds for protective correlates (8) . However, standardization is necessary to allow comparability of quantitative antibody test results. Therefore, an international standard for SARS-CoV-2 antibodies (National Institute for Biological Standards and Control [NIBSC] 20/136) was issued by the WHO to compare SARS-CoV-2 specific antibody levels better (9) . Although there is currently no general recommendation to determine antibody levels in all individuals after SARS-CoV-2 vaccination, this is reasonable from a scientific perspective and has been done in numerous studies (10) (11) (12) (13) . Moreover, it is now known that suboptimal or even lack of response to vaccination can occur in specific groups like immunocompromised patients (14, 15) . These potential nonresponders might be identified in a first step by determining the antibody levels after vaccination. Unfortunately, there is little scientific evidence on the real-life comparability of different commercially available quantitative test systems, especially after vaccination (16, 17) . We could previously show that reporting standardized binding antibody units (BAU/mL) is insufficient for different test systems to provide numerically comparable results (16) . Moreover, antibody responses are dependent on the type of vaccine used (18, 19) . In this view, the temporal kinetics of antibody levels after vaccination were described for different vaccines and different antibody assays (20) (21) (22) (23) . However, the factors that may influence the comparability of different quantitative SARS-CoV-2 antibody tests have not been sufficiently systematically studied. In the present work, we aimed to expand this knowledge using samples from AZD1222 vaccinated volunteers and tested antibody levels at multiple time points: 3 weeks after the first vaccine dose, 11 weeks after the first dose (immediately before the second dose), and 3 weeks after the second dose. Moreover, prebooster and postbooster levels were compared to SARS-CoV-2 specific T cell interferon g responses. We used two of the most widely applied commercially available assays, the Roche Elecsys SARS-CoV-2 S-ECLIA (24) and the Abbott Anti-SARS-CoV-2 IgG II (25) , to examine the comparability of the assays concerning the timing of blood collection after vaccination. Agreement between Roche and Abbott assays depends on the timing of blood collection. Blood samples of 50 individuals were collected 3 weeks and 11 weeks after the first dose of AZD1222 (11 weeks = "prebooster") and 3 weeks after the second dose ("postbooster") ( Fig. 1) . Participant characteristics and binding assay levels at all assessed time points are presented in Table 1 (27.4 to 191 .0) change in titers for Roche, and a 4.9-fold (3.0 to 10.1) and 4.5-fold (2.2 to 9.9) change for Abbott. Thus, the Roche test discriminated increases in antibody levels between weeks 3 and 11 after the first dose: 4.7-fold (2.2 to 9.5) change between weeks 3 and 11, whereas Abbott did not with a 0.8-fold (0.5 to 1.4) change between weeks 3 and 11. Three weeks after the first dose, results from Roche and Abbott binding assays showed a moderate correlation (r = 0.755, P , 0.0001). Passing-Bablok regression analysis revealed the equation Abbott = 7.4 1 2.99 Â Roche, whereby only the slope of the equation was statistically significant (2.06 to 17); intercept: (24.0 to 13.9). The agreement between both tests improved markedly 11 weeks after the first dose with the correlation coefficient rising to r = 0.902, P , 0.0001. Passing-Bablok regression revealed that BAU/mL derived from Abbott were approximately half those measured by Roche: Abbott = 1.1 1 0.50 Â Roche (intercept: 22.4 to 5.5, slope: 0.43 to 0.56). Three weeks after the second dose, the correlation between Roche and Abbott remained excellent (r = 0.950, P , 0.0001). However, the conversion between the values changed again, with Roche values approximately 5 to 6 times higher than Abbott = 13.3 1 0.178 Â Roche (intercept: 24.5 to 29.5; slope: 0.16 to 0.20) (Fig. 3 ). There were no significant correlations between age and antibody levels at any distinct point in time. However, the response to the booster shot (BAU/mL post-booster -BAU/mL pre-booster ) showed a moderate correlation with age for both the Roche (r = 0.29, P = 0.042) and the Abbott (r = 0.29, P = 0.040) assay. Correlation between binding assay and sVNT results. Next, we aimed to determine which of the two binding assays correlated better with neutralizing antibodies, particularly 3 weeks after the first dose, where the agreement between Roche and Abbott results was poorest. Neutralizing antibodies were estimated using the FDA-EUA approved (US)/ Conformitee Europeene -In-vitro diagnostic medical devices (CE-IVD) marked (Europe) cPass sVNT, with 30% inhibition as the threshold for positivity. Three weeks after the first dose, 44/50 (88%) participants yielded results above this threshold with a median inhibition of 47.1% (35.5 to 60.6). At week 11 directly before the booster, 4 of those with a negative result rose above 30% inhibition, but two with initially positive results decreased below the threshold, resulting in a total of 4 individuals (8%) below 30% inhibition. The median neutralizing capacity remained nearly unchanged at inhibition of 49.0% (35.2 to 62.4). Three weeks after the booster dose, all but one participant presented with at least medium neutralizing capacity (.60%; Fig. 2 ). The median increased to 95.2% inhibition (92.1 to 97.9) at week 3 post booster (Table 1 and Fig. 2B ). As shown in Fig. 4 , sVNT percent inhibition at 3 weeks after the first dose correlated with the Abbott assay at r = 0.887, P , 0.0001. In contrast, the correlation with the Roche test was slightly lower at r = 0.666 (P , 0.0001). At 11 weeks after the first dose, sVNT results correlated very well with both assays (Abbott: r = 0.930, Roche: r = 0.894; both P , 0.0001). Similar results were observed at 3 weeks after the booster (Abbott: r = 0.877, Roche: r = 0.837; both P , 0.0001). These data suggest that qualitative differences between early and late SARS-CoV-2 antibodies may affect the comparability of serological tests. Relative changes of T cell responses, but not absolute IFN-c levels, correlated with antibody levels. Finally, we examined the interactions between T cell and antibody responses (quantified with the Abbott and the Roche test). For this purpose, we compared the changes between the time before the booster (11 wk after the first dose) and the time after the booster (3 wk after the second dose), as the antibody response to the booster shot is by far more pronounced than that to dose 1, allowing larger effect sizes to be compared. Interferon-g (IFN-g) response to both used antigen mixtures (Ag1 and Ag2) increased after the booster shot: Ag1 negative (Ag1-Nil) 0.10 IU/mL (0.05 to 0.16) to 0.15 IU/mL (0.09 to 0.32), P , 0.0001; Ag2-Nil 0.16 IU/mL (0.09 to 0.31) to 0.31 IU/mL (0.16 to 0.98) ( Fig. 5 and Table 1 ). Levels from both antigen mixtures correlated well with each other (prebooster r = 0.725, P , 0.0001; postbooster r = 0.775, P , 0.0001; Fig. 5 ). Moreover, prebooster levels were in good agreement with postbooster levels (Ag1-Nil r = 0.786, P , 0.0001; Ag2-Nil r = 0.832, P , 0.0001). Prebooster IFN-g levels were only weakly correlated with antibody levels. Most correlations lacked statistical significance, and no relevant correlation was found 3 weeks after the booster. In contrast, the relative changes of cellular and binding assay antibody responses, calculated as 100 Â (postboosterprebooster)/prebooster, correlated significantly after incubation with Ag2. However, for Ag1, statistical significance could not be reached (Table 2) . Interestingly, no such correlation was observed for the sVNT. SARS-CoV-2 specific anti-spike protein assays have been and are still widely used for serological studies. While the distinction between positive and negative is usually sufficient in seroprevalence studies, quantitative results are needed to describe the immunogenicity of SARS-CoV-2 vaccines and, ideally, to find protection correlates (13, 26) . However, the quantitative results of different SARS-CoV-2 antibody tests must be comparable to summarize the results of different studies or to translate them to other situations (8, 9) . In the present work, we compared two commercially available and broadly used CE-IVD marked SARS-CoV-2 antibody assays (Roche and Abbott). Both assays quantitate antibodies directed against the RBD domain of the SARS-CoV-2 spike protein and were referenced against the first WHO standard for SARS-CoV-2 antibodies, thus providing results in BAU/mL. We demonstrated in a previous study after vaccination with BNT162b that despite the standardization of SARS-CoV-2 antibody assays, the numerical values of different test systems are not interchangeable (16) . Now we show for the first time that the problem of comparability is even more complex because the conversion between different assays can change dramatically with the time interval from vaccination. From studies with convalescents, we know that the levels of antibodies depend on the test system used and that, in addition, other differences may become observable over time, e.g., levels appear to decline more rapidly with one test than with another (27) . However, these findings cannot be transferred to the situation after vaccination without restrictions. There are known differences between the serostatus after infection and vaccination (28) , and the various vaccines also differ in this respect (29) . Using samples from 50 individuals vaccinated with AZD1222, we could show that both anti-spike antibody assays used (Abbott and Roche) detected specific antibodies in all but two participants 3 weeks after the first dose. Both nonresponders were taking immunosuppressive drugs, which can lead to a decreased to absent response to the vaccine (30) (31) (32) . However, after the second dose, the antibody levels markedly increased and reached detectable levels in all participants (Table 1 and Fig. 2A ). In contrast to people with previous COVID (33) (34) (35) , the second dose was required in our SARS-CoV-2 naive population to induce high antibody levels. The median relative change of individual antibody levels 3 weeks after the first versus 3 weeks after the second dose was nearly 20-times higher for Roche than for Abbott (80.8 versus 4.5-fold change; Fig. 2B ). Despite targeting the same antigen (RBD) and reporting in BAU/mL, not even the relative increases in antibody levels turned out to be comparable. Of course, it should be mentioned that the exact antigens used in the two test systems are unlikely to be identical, and therefore such differences may be due to different epitope specificities. Furthermore, Abbott and Roche differ in the test format where the former uses classical IgG-specific detection, whereas the latter applies a sandwich format to bind all antibody isotypes potentially. The limited comparability of serological assays after vaccination is not specific for the AstraZeneca vaccine, as it was also observed after immunization with Pfizer/BioNTech BNT162b2 (16) . When looking at the difference between 3 and 11 weeks after the first vaccination dose, it was found that both the Abbott test and the cPass sVNT did not detect an increase in antibodies (Fig. 2) . In contrast, antibody levels measured by the Roche test increased .4-fold during this period. This discrepancy could be either explained by the inability of the Abbott and sVNT assays to distinguish such small changes in antibody concentration or the possibility that the Roche assay detects not only quantitative but also qualitative changes of the antibodies formed. Because previous studies failed to demonstrate a continuous increase in antibody levels for AZD1222 later than 3 weeks after vaccination, the Roche total antibody sandwich assay may also be sensitive to qualitative changes in nascent antibodies (e.g., antibody maturation), in contrast to the Abbott IgG-specific assay (12, 36) . This hypothesis is also supported by the observation that in direct comparison with the sVNT, the Roche assay underestimated inhibitory capacities at week 3 (Fig. 4) , which is discussed in detail below. Thus, the assays studied show significant differences in the kinetics of antibody levels, which has been reported previously but was only rarely demonstrated from the same sample with different assays (17, 37) . Although the correlation between Roche and Abbott improved over time, their relationship changed significantly depending on the time of blood sampling (Fig. 3) . At the first time point, Roche measured three times lower values in BAU/mL than the Abbott assay, 11 weeks after the first dose, Roche measured twice as high as Abbott, and finally, after the booster, Roche was median 5 to 6 times higher than Abbott. Currently, further evidence is lacking on whether the association between two antibody tests can become constant and at what time interval to the second dose this would be the case. But it should also be considered that each new stimulus of antibody formation would lead to different ratios. Considering the ongoing administration of a third dose and already starting vaccination of fourth doses, continuous ratios changes would be likely. It is important to note that, unlike other comparative (often retrospective) studies, we did not choose time intervals but clearly defined time points in this prospective observational study. Therefore, an accurate assessment of the observed time-dependent effects was possible, which could otherwise be overlooked. As studies have shown before that detection of SARS-CoV-2 anti-spike binding antibodies correlates well with the presence of functional neutralizing antibodies, we wanted to examine differences between Roche and Abbott assays in this regard (38) (39) (40) (41) (42) (43) . The agreement between the results of the binding antibody assays and the neutralization test surrogate was generally good (Fig. 4) . At 11 weeks after the first vaccination, the correlation was excellent; after the booster, the correlation was technically limited due to many participants reaching the plateau of the sVNT. However, the worst correlation was found for the first antibody response 3 weeks after the first dose, and here Roche performed significantly worse than Abbott. This finding may be important because the improvement in Roche/ sVNT correlation from r = 0.666 to r = 0.894 between 3 and 11 weeks after the first dose may indicate reduced sensitivity of the Roche assay for early antibodies. In other words, the discrepancy mentioned above that only Roche showed increasing antibody levels between 3 and 11 weeks after the first dose, while the other two tests showed identical or even slightly decreasing levels (Fig. 2) , could mean that the Roche test requires more matured antibodies to allow binding. In line with previous studies, the second dose of AZD1222 substantially enhanced the initial antibody response in our cohort (19, 36, 44) . Because the formation of antibodies is physiologically supported by specific T cells, we assumed a correlation between T cell response and antibody formation. Therefore, we aimed to additionally investigate the cellular responses elicited by the second dose. For this purpose, we used a SARS-COV-2 Quantiferon IFN-g release assay similar to those known from tuberculosis diagnostics and compared the time points before and after the second vaccine dose. As previously shown (45) , the second dose induced an increase in cellular reactivity in most cases (Fig. 5) . Three participants presented negative responses to Ag1 and Ag2, but the decreases were only moderate (0.04 to 0.07 IU/mL). The antibody responses in these participants were comparable to those seen in the rest of the cohort. However, we found only weak, mostly statistically nonsignificant correlations between antibody levels and absolute IFN-g levels before the second dose and no correlation at all after the second dose (Table 2 ). In contrast, the percent cellular response (fold change) to the second dose correlated significantly with the percent antibody response (r = 0.33 for both binding assays), see Table 2 . This finding suggests that the increase of antibodies after a second shot, which is detected by both binding assays, can be substantiated by an accompanying cellular reaction. In contrast, we found no correlation between the relative changes in cellular and sVNT response, which might be partly explained by the limited measurement range of the sVNT. However, because not all antibodies formed are functionally active neutralizing antibodies (NAbs), even not all of those specifically directed against the receptor-binding domain (RBD) of the spike protein, the binding antibodies may be superior to the measurement of NAbs here as a correlate for cellular activation. This study has several strengths and limitations: although 50 participants might be considered a relatively small cohort, we have shown in previous work that this number is sufficient for such comparative approaches and that our data could be replicated in much larger cohorts (16, 46) . One strength of our study is that we followed exact time points for blood sampling in the context of a prospective observational study. A limitation is that we did not perform measurements beyond 3 weeks after the second dose. Thus, whether a constant ratio would be observed after a specific time is unclear. Furthermore, our cohort using AZD1222 (inducing significantly lower median antibody levels than, e.g., BNT162b2) has the advantage of a broader distribution of values across the measurable spectrum with a very low proportion of results above 1,000 BAU/mL. As this value represents the upper limit of referencing with the WHO SARS-CoV-2 antibody standard, a linear relationship is no longer guaranteed for values above this, leading to unwanted biases in comparing different antibody tests. In summary, with the present work, we show for the first time that the comparability of quantitative anti-spike SARS-CoV-2 antibody tests is highly dependent on the timing of blood collection. Although the results of the two assays studied correlate well at all time points, a numerical agreement is only possible through a correction factor, which changes over time after both the first dose of vaccine and the stimulus of the second dose of vaccine. Concerning boosters with a 3rd and possibly fourth dose, we must assume that the relationship between two antibody assays may be in a constant state of change. Therefore, it does not seem feasible to compare different quantitative SARS-COV-2 antibody results without standardization of the time of sample collection. Study design and participants. We included sera of 50 participants in this prospective observational performance evaluation study. Inclusion criteria were an age $18 years and willingness to donate blood during the MedUni Wien Biobank's healthy blood donor collection (Medical University of Vienna ethics committee vote no. 404/2012). Incomplete follow-up samples and seropositivity for anti-nucleocapsid antibodies due to infection with SARS-CoV-2 lead to exclusion. The study protocol was reviewed and approved by the Medical University of Vienna ethics committee (1066/2021) and conforms with the Declaration of Helsinki. Laboratory methods. Blood samples were taken 3 weeks and 11 weeks ("prebooster") after the first dose of AZD1222, as well as 3 weeks after dose 2. At prebooster and postbooster time points, an additional amount of 4 mL blood was drawn to estimate T cell immunity (Fig. 1) . Blood samples were processed and stored according to standard operating procedures by the MedUni Wien Biobank in an ISO 9001:2015 certified environment (47) . Previous SARS-CoV-2 infection was assessed by the Roche Elecsys SARS-CoV-2 nucleocapsid ECLIA (Roche, Rotkreuz, Switzerland) on Cobas e801 modular analyzers (Roche) (48) . This assay detects total antibodies against the viral nucleocapsid, which are induced after infection, but not after vaccination with AZD1222. To not miss a previous infection by antibody waning, the response to the first dose was monitored; convalescent vaccinees usually react with a pronounced antibody response to dose 1 that is comparable to the response to dose 2 in naive individuals (33) . Vaccine-induced antibodies against the viral spike protein were quantified using the Roche Elecsys SARS-CoV-2 S-ECLIA (49) and the Abbott Anti-SARS-CoV-2 IgG II (50) . This Roche test is a quantitative (range: 0.4 to 2,500 BAU/mL, whereby the conversion factor of the system's arbitrary U/mL to BAU/mL is 1.0) total antibody sandwich assay recognizing antibodies directed against the receptor-binding domain (RBD) of the SARS-CoV-2 spike (S) protein and was performed on Cobas e801 modular analyzers (Roche), samples .0.8 BAU/mL are considered diagnostically positive. As a deviation from the product manual, samples exceeding the quantification range were manually prediluted at a dilution factor of 1:10. The Abbott assay also quantifies anti-RBD specific IgG-antibodies (range:1.0 to 11,360.0 BAU/mL, whereby the arbitrary AU/mL have been converted to BAU/mL by multiplying them with 0.142) and was applied on an Abbott Architect i2000r (Abbott, USA). The assay's threshold for positivity is 7.1 BAU/mL, which equals 50 AU/mL. Binding reactivities (Roche, Abbott) were compared to a well-described CE-IVD marked surrogate virus neutralization test (GenScript cPass sVNT) (51, 52) . This sVNT quantifies the serum's ability to inhibit spike/ACE-2 interaction. Results with an inhibition .30% are considered positive. The T cell activity was estimated in prebooster and postbooster whole blood samples using the Quantiferon SARS-CoV-2 assay (Qiagen, Hilden, Germany [53] [54] [55] ). In brief, we quantified the IFN-g-release after a 21 h incubation of 1 mL heparinized whole blood portions with two different SARS-CoV-2 antigen mixtures (Ag1, Ag2), and with a negative ("Ce point, IFN-g) values of the negative (Nil) control were subtracted from the SARS-CoV-2 specific antigen mixes results of the samples and presented as Ag1-Nil and Ag2-Nil, respectively. Available literature suggests a cutoff around 0.15 to 0.20 IU/mL for detecting a specific response (54) . Recently, the technically identical test has become available as an IVD certified test, and the manufacturer recommends a cutoff for positivity of $0.15. Statistical analysis. Continuous data are presented as median (interquartile range), and categorical data as counts (percentages). Paired data are compared by Wilcoxon and Friedman tests. Correlations are calculated according to Spearman. Serological assays are compared by Passing-Bablok regressions, which assess differences between two test systems by estimating the slope (systematic proportional differences) and the intercept (systematic constant differences) of a linear regression line. There are no preconditions regarding the distribution of the measured values and the measurement errors to be met. P values ,0.05 were considered statistically significant. All calculations have been performed using MedCalc 19.7 (MedCalc Bvba, Ostend, Belgium) and SPSS 26 (IBM, Armonk, USA). Graphs were drawn with Prism 9 (GraphPad, La Jolla, USA). Grand Challenges in Infectious Diseases: are We Prepared for Worst-Case Scenarios? SARS-CoV-2 vaccines in development Safety and Immunogenicity of Two RNA-Based Covid-19 Vaccine Candidates Three-quarters attack rate of SARS-CoV-2 in the Brazilian Amazon during a largely unmitigated epidemic Prevalence of SARS-CoV-2 in Spain (ENE-COVID): a nationwide, populationbased seroepidemiological study Meta-analysis of diagnostic performance of serology tests for COVID-19: impact of assay design and post-symptom-onset intervals Immunology of COVID-19: current State of the Science SARS-CoV-2 Serologic Assay Needs for the Next Phase of the US COVID-19 Pandemic Response WHO International Standard for anti-SARS-CoV-2 immunoglobulin Immune responses to a single dose of the AZD1222/Covishield vaccine in health care workers Immunogenicity and reactogenicity of heterologous ChAdOx1 nCoV-19/mRNA vaccination Antibody responses to SARS-CoV-2 vaccines in 45,965 adults from the general population of the United Kingdom Team § USG (USG)/CoVPN B. 2022. Immune correlates analysis of the mRNA-1273 COVID-19 vaccine efficacy clinical trial SARS-CoV-2 vaccination in rituximab-treated patients: B cells promote humoral immune responses in the presence of T-cell-mediated immunity Immunogenicity of SARS-CoV-2 Vaccine in Dialysis Anti-Spike Protein Assays to Determine SARS-CoV-2 Antibody Levels: a Head-to-Head Comparison of Five Quantitative Assays Usefulness of IVD Kits for the Assessment of SARS-CoV-2 Antibodies to Evaluate the Humoral Response to Vaccination Quantitative SARS-CoV-2 antispike responses to Pfizer-BioNTech and Oxford-AstraZeneca vaccines by previous infection status Initial SARS-CoV-2 vaccination response can predict booster response for BNT162b2 but not for AZD1222 Three-month analysis of total humoral response to Pfizer BNT162b2 mRNA COVID-19 vaccination in healthcare workers The dynamics of quantitative SARS-CoV-2 anti-spike IgG response to BNT162b2 vaccination Differential Antibody Response to mRNA COVID-19 Vaccines in Healthy Subjects Group § T mRNA-1273 S. 2021. Durability of mRNA-1273 vaccine-induced antibodies against SARS-CoV-2 variants Immunogenicity and reactogenicity of BNT162b2 booster in ChAdOx1-S-primed participants (CombiVacS): a multicentre Antibody responses to the BNT162b2 mRNA vaccine in individuals previously infected with SARS-CoV-2 Covid-19 Breakthrough Infections in Vaccinated Health Care Workers SARS-CoV-2 Serologic Assays Dependent on Dual-Antigen Binding Demonstrate Diverging Kinetics Relative to Other Antibody Detection Methods Comparative kinetics of SARS-CoV-2 anti-spike protein RBD IgGs and neutralizing antibodies in convalescent and naïve recipients of the BNT162b2 mRNA vaccine versus COVID-19 patients Differential Kinetics of Immune Responses Elicited by Covid-19 Vaccines Antibody Response After a Third Dose of the mRNA-1273 SARS-CoV-2 Vaccine in Kidney Transplant Recipients With Minimal Serologic Response to 2 Doses Anti-CD20 therapies decrease humoral immune response to SARS-CoV-2 in patients with multiple sclerosis or neuromyelitis optica spectrum disorders Antibody development after COVID-19 vaccination in patients with autoimmune diseases in the Netherlands: a substudy of data from two prospective cohort studies Serum antibody response to BNT162b2 after natural SARS-CoV-2 infection Antibody Responses in Seropositive Persons after a Single Dose of SARS-CoV-2 mRNA Vaccine Antibody Responses after a Single Dose of SARS-CoV-2 mRNA Vaccine Phase 1/2 trial of SARS-CoV-2 vaccine ChAdOx1 nCoV-19 with a booster dose induces multifunctional antibody responses Comparison of five commercial anti-SARS-CoV-2 total antibodies and IgG immunoassays after vaccination with BNT162b2 mRNA Clinical validation of the Siemens quantitative SARS-CoV-2 spike IgG assay (sCOVG) reveals improved sensitivity and a good correlation with virus neutralization titers Clinical, laboratory, and temporal predictors of neutralizing antibodies against SARS-CoV-2 among COVID-19 convalescent plasma donor candidates Longitudinal Serological Analysis and Neutralizing Antibody Levels in Coronavirus Disease 2019 Convalescent Patients Serological Assays Estimate Highly Variable SARS-CoV-2 Neutralizing Antibody Activity in Recovered COVID-19 Patients Longitudinal observation and decline of neutralizing antibody responses in the three months following SARS-CoV-2 infection in humans Comparison of virus neutralization activity and results of 10 different anti-SARS-CoV-2 serological tests in COVID-19 recovered plasma donors Immune responses against SARS-CoV-2 variants after heterologous and homologous ChAdOx1 nCoV-19/BNT162b2 vaccination Safety and immunogenicity of ChAdOx1 nCoV-19 vaccine administered in a prime-boost regimen in young and old adults (COV002): a single-blind, randomised, controlled, phase 2/3 trial Impact of age, ethnicity, sex and prior infection status on immunogenicity following a single dose of the BNT162b2 mRNA COVID-19 vaccine: real-world evidence from healthcare workers, Israel Usage Data and Scientific Impact of the Prospectively Established Fluid Bioresources at the Hospital-Based MedUni Wien Biobank Side by side comparison of three fully automated SARS-CoV-2 antibody assays with a focus on specificity Quantitative measurement of anti-SARS-CoV-2 antibodies: analytical and clinical evaluation Clinical evaluation of the Abbott Alinity SARS-CoV-2 spike-specific quantitative IgG and IgM assays among infected, recovered, and vaccinated groups Validation of a commercially available indirect assay for SARS-CoV-2 neutralising antibodies using a pseudotyped virus assay Dual-Purpose Serology Test: highly Accurate Infection Tracing and Neutralizing Antibody Response Detection Poor humoral and Tcell response to two-dose SARS-CoV-2 messenger RNA vaccine BNT162b2 in cardiothoracic transplant recipients Preliminary Evaluation of QuantiFERON SARS-CoV-2 and QIAreach Anti-SARS-CoV-2 Total Test in Recently Vaccinated Individuals Evaluation of the QuantiFERON SARS-CoV-2 Interferon-ɣ release assay in mRNA-1273 vaccinated health care workers We thank all sample donors for their valuable contributions. We further thank Martina Trella, Susanne Keim, Borka Radovanovic-Petrova, Monika Martiny, Jadwiga Konarski, Bernhard Haunold, Maedeh Iravany, and Shohreh Lashgari for perfect technical and administrative assistance. The MedUni Wien Biobank is part of the Austrian biobanking consortium BBMRI.at.There was no specific funding received for the present work. The authors declare a conflict of interest. The Department of Laboratory Medicine received compensation for advertisement on scientific symposia from Roche and Abbott and holds a grant for evaluating an in vitro diagnostic device from Roche.