key: cord-0726142-wvixyfsv authors: Pastorino, Boris; Touret, Franck; Gilles, Magali; de Lamballerie, Xavier; Charrel, Remi N. title: Heat Inactivation of Different Types of SARS-CoV-2 Samples: What Protocols for Biosafety, Molecular Detection and Serological Diagnostics? date: 2020-07-07 journal: Viruses DOI: 10.3390/v12070735 sha: 5c744fc268a062abfafcb72986ce7ca92acf149c doc_id: 726142 cord_uid: wvixyfsv Standard precautions to minimize the risk of SARS-CoV-2 transmission implies that infected cell cultures and clinical specimens may undergo some sort of inactivation to reduce or abolish infectivity. We evaluated three heat inactivation protocols (56 °C-30 min, 60 °C-60 min and 92 °C-15 min) on SARS-CoV-2 using (i) infected cell culture supernatant, (ii) virus-spiked human sera (iii) and nasopharyngeal samples according to the recommendations of the European norm NF EN 14476-A2. Regardless of the protocol and the type of samples, a 4 Log(10) TCID50 reduction was observed. However, samples containing viral loads > 6 Log(10) TCID(50) were still infectious after 56 °C-30 min and 60 °C-60 min, although infectivity was < 10 TCID(50). The protocols 56 °C-30 min and 60 °C-60 min had little influence on the RNA copies detection, whereas 92 °C-15 min drastically reduced the limit of detection, which suggests that this protocol should be avoided for inactivation ahead of molecular diagnostics. Lastly, 56 °C-30 min treatment of serum specimens had a negligible influence on the results of IgG detection using a commercial ELISA test, whereas a drastic decrease in neutralizing titers was observed. Since December 2019, measures to reduce person-to-person transmission of SARS-CoV-2 have been implemented in an attempt to control the COVID-19 outbreak. Tremendous efforts are being done by an increasing number of laboratory personnel working daily with infectious samples, and thus are heavily exposed to the risk of infection [1] [2] [3] . Accordingly, the WHO introduced laboratory guidelines to mitigate this risk for diagnosis and research activities [4] . Nonetheless, laboratory workers processing clinical samples will continue to be exposed to infectious SARS-CoV-2 [5] . Moreover, even if this enveloped virus is supposed to be fragile, it can persist in the environment for extended periods of time [6] , and understanding the potential effect of heat inactivation of the pandemic SARS-CoV-2 coronavirus is also relevant to elaborate proper public intervention measures. In this work, we evaluated three heat inactivation protocols on different types of SARS-CoV-2 infectious samples in order to determine the efficacy in reducing the infectivity and the influence of these protocols on both the detection of viral RNA and the results of two serological assays. Three types of sample were used for assessing the efficacy of heat inactivation protocols: (i) SARS-CoV-2 infected Vero-E6 cell supernatants (with or without supplementation with 3g/L bovine serum albumine [BSA]), (ii) nasopharyngeal samples (NPS) collected in patients, (iii) and sera from blood donors (BD); the two latter were collected before the COVID-19 pandemic period, and were negative for SARS-CoV-2 RNA and for SARS-CoV-2 antibodies, respectively. NPS were collected into 1 mL of viral transport media (Virocult ® , Sigma). They were pooled in order to constitute a homogeneous material that was spiked with infectious SARS-CoV-2 to a final titer ranging from 10 5 to 10 6 TCID 50 /mL depending on the sample type. Spiked material was then distributed in 300 µL aliquots before performing the different heating protocols. The same approach was applied to BD sera. The virucidal activity of different heat protocols was determined according to the European Standards NF EN 14476-A2 (https://www.analytice.com/en/nf-en-14476-laboratory-biocide-efficacy-test/). Briefly, a 300-µL sample containing 10 5 to 10 6 TCID 50 /mL was incubated in a pre-warmed dry heat block using either of the three following protocols: 56 • C-30 min, 60 • C-60 min and 92 • C-15 min, after which the treated sample was immediately titrated (TCID 50 ) and tested for RNA copies (Table 1) . Virus titration and RT-qPCR were performed before and after heating to measure the viral load reduction factor and variation in RNA copies. Samples were tested in duplicates (cell supernatants) or in six replicates (NPS and BD sera). For NPS and BD sera, the 92 • C-15 min protocol was not performed because of its poor suitability for practical applications in clinical microbiology laboratories [8] . a Mean value ± SD according to the Karber formula as described in the Materials and Methods section; b Ct Var, Cycle threshold variation = Ct value (before inactivation)-Ct value (after inactivation); c two replicates; d six replicates; e not detected (both replicates or all 6 replicates depending upon the type of sample). All samples were quantified by end-point titration on Vero E6 cells with a limit of detection of about 10 0.5 TCID 50 /mL. Heat inactivated samples and control samples were extracted using the Qiacube HT and the Cador pathogen extraction kit (both from Qiagen, Venlo, The Netherlands). Viral RNA was quantified by RT-qPCR (qRT-PCR EXPRESS One-Step Superscript™, ThermoFisher Scientific, Waltham, Massachusetts) (10 min-50 • C, 2 min-95 • C, and 40 times 95 • C-3 s/60 • C-30 s) using serial dilutions of a T7-generated synthetic RNA standard. Primers and probe target the N gene (Fw: GGCCGCAAATTGCACAAT; Rev: CCAATGCGCGACATTCC; Probe: FAM-CCCCCAGCGCTTCAGCGTTCT-BHQ1. The calculated limit of detection was 10 RNA copies per reaction. To address whether heating sera at 56 • C for 30 min may affect the results observed with two serological assays, a total of 38 SARS-CoV-2 positive human sera were selected, processed and reanalyzed comparatively as detailed hereunder. The semi-quantitative anti-SARS-CoV-2 ELISA for immunoglobulin class G (EI 2606-9601 G, Euroimmun AG, Lübeck, Germany) was used as recommended by the manufacturer. The optical density (OD) was detected at 450 nm, and a ratio of the reading of each sample to the reading of the calibrator was calculated for each sample (OD ratio). Samples were considered positive when OD ratio >1.1. A virus neutralization test (VNT) was performed as previously described [9] . Briefly, VNT was performed in a 96-well format, using Vero-E6 cells and virus strain described in 2.1. Two-fold serial dilutions of sera were mixed with 100 TCID 50 , resulting in final serum dilutions ranging from 1/20 to 1/160, and incubated for 1 h at 37 • C. Serum+virus was transferred onto the confluent cell monolayer, and incubated at 37 • C in a 5% CO 2 atmosphere. Positive and negative control wells, containing virus+cells and cells only, respectively, were included in each series. After 4 days, the plates were examined for the presence (no neutralization) or absence (neutralization) of CPE using an inverted microscope. The three protocols resulted in a clear decrease in the infectivity after treatment with a reduction factor that was equal or higher than 5 Log 10. Accordingly, based on the NF EN 14476-A2, they all were considered as virucidal (Table 1) . However, some of the samples treated with the 56 • C-30 min and 60 • C-60 min protocols remained infectious, whereas virus recovery was not possible with the samples treated with the 92 • C-15 min protocol. There was no difference between clean or dirty conditions, meaning that an interfering substance (i.e., high level of proteins) did not hamper the efficacy of heating as an inactivation method. Interestingly, the 92 • C-15 min protocol resulted in a drastic reduction in the detectable RNA copies (∆Ct > 5) before and after heat treatment (8 × 10 6 vs. 1.6 × 10 5 RNA copies). This is an important point because it should alert us to the fact that heat-inactivated samples may not be suitable for viral RNA detection due to the possible decrease in the sensitivity and increase in the limit of detection (LoD), with expected false negative results. The two protocols (56 • C-30 min and 60 • C-60 min) resulted in a clear drop in infectivity (>5 Log 10 reduction) ( Table 1 ). Both protocols did not affect the number of detectable RNA copies samples (Ct Var < 2). The two protocols (56 • C-30 min and 60 • C-60 min) resulted in a clear drop in infectivity (>5 Log 10 reduction) ( Table 1 ). Both protocols did not affect the number of detectable RNA copy samples, although 56 • C-30 min had a lower impact on the LoD (Ct Var Ct < 1 vs. < 2). A total of 38 sera from patients with RT-qPCR-established SARS-CoV-2 infection were collected during the convalescent phase and tested using both serological assay in order to compare the results observed with and without heating at 56 • C-30 min. The aim was to address whether 56 • C-30 min could influence the results of two serological assays or not. There was no difference in the results observed with the two protocols, neither in the final results (negative/positive with 1.1 cut-off threshold) nor when OD ratios were compared ( Figure 1 ). Together, these results demonstrate that 56 • C-30 min had a negligible influence on ELISA results. In addition, ten sera collected from patients during the pre-pandemic period in 2019 were negative with and without 56 • C-30 min treatment [10] . There was a clear difference when using heated sera compared to unheated sera ( Figure 2 ). Lower titers were observed after the 56 • C-30 min protocol in 36 of the 38 tested sera; only sera #4 and #30 showed equal titers with and without heating. Sixteen sera showed titer reduction of one dilution, whereas the remaining 20 sera showed titers that were decreased by at least 2 dilutions after heating. Considering a qualitative analysis (positive/negative using 20 as the cut-off titer), 12 sera that were positive in the absence of heat treatment shifted into the negative group, leading to a total of 31% false negatives in our series. Understanding the potential effect of heat inactivation on the novel coronavirus SARS-CoV-2 is important in environmental and laboratory conditions in order to elaborate adapted biosafety protocols. Owing to the contagiousness of SARS-CoV-2, heat inactivation can be considered (i) for abolishing virus infectivity or (ii) for reducing the infectivity by viral load reduction. In this study, we used three different types of sample in order to mimic situations encountered in laboratory and non-laboratory environments. SARS-CoV-2-infected cell culture supernatant is commonly manipulated in BSL3 laboratories where the virus is grown for research or diagnostic activities. Nasopharyngeal samples (NPS) are clinical specimens that are manipulated by medical and laboratory personnel in routine care and diagnostic activities. Lastly, serum specimens are commonly manipulated in various types of laboratory activities in and outside of the field of virology. Therefore, addressing the effects of three heating protocols onto these different types of samples is important to better understand their possible use to reduce or suppress the infectivity of the SARS-CoV-2 and to define biosafety measures. The possible influence of heating protocols on the results of virological techniques is also important to address to avoid a loss of sensitivity and false negative results in diagnostic procedures. As 60 • C-60 min can be detrimental for serology and 92 • C 15 min results in a clear drop in RNA quantity detection, these protocols were excluded from certain modules of our study. According to the European norm NF EN 14476-A2, the protocols tested in this study can be considered as virucidal, i.e., achieving a 4 Log 10 reduction in infectivity for all tested samples (cell supernatant, virus-spiked serum or nasopharyngeal samples). However, in our experimental conditions, samples containing viral loads > 6 Log 10 TCID 50 remain infectious after 56 • C-30 min and 60 • C-60 min, although the risk of infection at the individual level with samples containing viral loads below 10 TCID 50 is not established. In any case, the postulate is that if a given viral load can infect the cell monolayer, the risk of human infection exists. Interestingly, the efficacy of the 56 • C-30 min and 60 • C-60 min protocols are in line with results observed using canine coronavirus and mouse hepatitis coronavirus (3.88 to 4.51 Log 10 reduction factor) with 60 • C for 30 min [11] . However, 56 • C-30 min appears much less efficient on SARS-CoV-2 than on transmissible swine gastroenteritis virus, an alpha coronavirus, showing a reduction in infectivity of >7.5 Log 10 units [12] . This suggests that the inactivation of clinical samples ahead of molecular diagnosis should also consider chemical inactivation as an alternative to heat inactivation for SARS-CoV-2 diagnostics [13] . In this study, the lack of impact of 56 • C-30 min and 60 • C-60 min protocols on RNA copies detection confirms recently reported results [14] ; however, in contrast, the latter reported a lower decrease in copy number detectable after 95 • C-3 min (∆Ct = 2.2) compared to the ∆Ct > 5 after 92 • C-15 min we observed. This is not totally unexpected because of differences in the two protocols. This also raises questions about the possibility to inactivate high viral loads within respiratory samples by short heating at high temperature, an option that is increasingly debated with protocol replacing nucleic acid extraction by heat denaturation [15] [16] [17] . It is clear that additional studies are needed to elaborate heating protocols achieving infectivity loss together with unchanged detectable copy number. Complement inactivation through 56 • C-30 min heating is common before ELISA serology. Additionally, 60 • C-60 min and 56 • C-30 min are used for reducing the potential infectivity of the samples processed for serology [18] ; however, either of these treatments may have a deleterious impact on the results qualitatively or quantitatively [19] . The aim was to address whether 56 • C-30 min could influence the results of two serological assays or not. In contrast with Hu et al. [19] , our results suggest that 56 • C-30 min does not affect, either qualitatively nor quantitatively, the detection of SARS-CoV-2 specific IgG using a commercially available ELISA test. However, 56 • C-30 min had a noticeable effect on the detection of neutralizing antibodies. To the best of our knowledge, this has not been described previously, either for coronaviruses or for other viruses. One recent study reported that combining 56 • C-30 min with phosphate buffered saline-Tween20 (0.3%) supplementation (vol/vol) with (0.15% final concentration) influenced neutralization titers, specifically when they ranged from 20 to 80 (up to 30% of sera showed measurable impact on the result) [20] . Although we have no evidence-based information to explain this phenomenon, it could be due to (i) the partial heat denaturation of antibodies, changing their ability to neutralize the virus but not the antigen binding or (ii) the presence in the serum of components, other than antibodies, that are heat-sensitive, such as the complement as described for Junín virus and human cytomegalovirus [21, 22] . Further studies are needed to assess whether this phenomenon is virus-dependent or more widely observed. In conclusion, the results observed in this study should be taken into consideration for sorting serum samples according to the subsequent serological assays to be performed. Upon reception, aliquoting of serum samples is necessary to allow different processes downstream. Since ELISA is commonly used as a screening test before ELISA-positive sera are confirmed by neutralization assay, performing VNT using heat-inactivated sera can result in reduced titers and in false negative results. Therefore, we advocate that heat inactivation is performed on aliquots before ELISA and that confirmation VNT is performed with unheated aliquots. Finally, this study should help to choose the best-suited protocol for inactivation in order to prevent the exposure of laboratory personnel in charge of direct and indirect detection of SARS-CoV-2 for diagnostic or research purposes. Funding: This study was partially funded (i) by the European Virus Archive Global (EVA-GLOBAL) project that has received funding from the European Union's Horizon 2020-INFRAIA-2019 project No 871029, (ii) "Advanced Nanosensing platforms for Point of care global diagnostics and surveillance" (CONVAT) H2020 Project No101003544, (iii) PREPMedVet (Preparedness and Response in an Emergency contact to Pathogens of Medical and Veterinary importance) within the Agence Nationale de la Recherche Franco-German call on Civil security/Global security 2019 Edition, (iv) "Viral Hemorrhagic fever modern approaches for developing bedside rapid diagnostics", IMI2 Program, H2020, Project No823666. It was also supported by Inserm through the Reacting (REsearch and ACTion Targeing emerging infectious diseases) initiative. Transmission of SARS and MERS coronaviruses and influenza virus in healthcare settings: The possible role of dry surface contamination Role of fomites in SARS transmission during the largest hospital outbreak in Hong Kong Surface Environmental, and Personal Protective Equipment Contamination by Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) From a Symptomatic Patient Laboratory Biosafety Guidance Related to Coronavirus Disease 2019 ( COVID-19): Interim Guidance Microbial Inactivation for Safe and Rapid Diagnostics of Infectious Samples Aerosol and Surface Stability of SARS-CoV-2 as Compared with SARS-CoV-1 A simple method of estimating fifty per cent endpoints Temperature Tolerance and Inactivation of Chikungunya Virus. Vector Borne Zoonotic Dis Combination of ELISA screening and seroneutralisation tests to expedite Zika virus seroprevalence studies Absence of Effect of 56 • C-30 min Treatment on SARS-CoV-2 ELISA Using Pre-Pandemic Serum Samples Virucidal efficacy of physico-chemical treatments against coronaviruses and parvoviruses of laboratory animals A cytopathic virus causing a transmissible gastroenteritis in swine. I. Isolation and properties Evaluation of Chemical Protocols for Inactivating SARS-CoV-2 Infectious Samples Heat inactivation of the Severe Acute Respiratory Syndrome Coronavirus 2. bioRxiv 2020 Development of a TaqMan®RT-PCR assay without RNA extraction step for the detection and quantification of African Chikungunya viruses Direct RT-qPCR detection of SARS-CoV-2 RNA from patient nasopharyngeal swabs without an RNA extraction step Potential false-negative nucleic acid testing results for Severe Acute Respiratory Syndrome Coronavirus 2 from thermal inactivation of samples with low viral loads General Procedures for Inactivation of Potentially Infectious Samples with Ebola Virus and Other Highly Pathogenic Viral Agents Heat inactivation of serum interferes with the immunoanalysis of antibodies to SARS-CoV-2. medRxiv 2020 Inactivation of Classical Swine Fever Virus in Porcine Serum Samples Intended for Antibody Detection Actions of complement on Junin virus Complement enhances in vitro neutralizing potency of antibodies to human cytomegalovirus glycoprotein B (gB) and immune sera induced by gB/MF59 vaccination We wish to thank Christine Isnard for excellent technical assistance. The authors declare no conflict of interest