key: cord-0744348-tshmr04g authors: Kintzios, Spyridon title: Bioelectric Sensors: On the Road for the 4.0 Diagnostics and Biomedtech Revolution date: 2020-08-11 journal: Biosensors (Basel) DOI: 10.3390/bios10080096 sha: ff24a92c28a51afd2a2f6f7b1d39e8770e14ecd3 doc_id: 744348 cord_uid: tshmr04g Bioelectric sensors lie, by definition, on the interface between biological elements and electronic circuits, irrespective of scale, manufacturing method, and working principle [...]. on system integration to deliver practical point-of-care/portable and wireless instrumentation and intelligent bioelectric sensing platforms. These will be presented in more detail in following. Organic biosensors with minimum power consumption represent the next stage of pulse meters, i.e., devices serving as non-invasive rapid medical diagnostic tools by measuring the rate of rhythmic contraction and expansion of an artery, in sync with the heart. They are based on the photoplethysmogram (PPG) principle, according to which, changes in reflected light, detectable as a PPG signal, correspond to changes in the volume of the underlying artery. In their contribution, Elsamnah et al. [20] report the development of a novel organic optoelectronic device purposed as a pulse oximeter and based on two alternative designs using large organic photodiodes (OPDs) and organic light-emitting diodes (OLEDs). These two models were simulated by representing the simplified four-layer structure of a finger model, with red OLED being preferred over green and infrared ones. Both devices were reliable and obtained a clear and stable PPG signal from a healthy individual, with minimum power consumption in wireless monitoring of PPG waveforms. The biosensor pulse meter showed promising results with ultra-low power consumption, 8 µW at 18 dB signal-to-noise ratio (SNR), and demonstrated its ability to measure a clear PPG signal up to 46 dB SNR at a constant current of 93.6 µA. Coupled with a low manufacturing cost, the novel system is very promising for long-term wireless PPG signal monitoring, possibly also as part of a wearable medical device. Next, Kiani et al. [21] report on the combination of a miniaturized-and therefore fully portable-p-n junction-based Si biochip with impedance spectroscopy, and using the industrial metal-binding, metal-remediating bacteria Lysinibacillus sphaericus JG-A12 as the biosensing element. The ohmic or Schottky contacts in the biochip was modelled as the combination of resistors and capacitors, while impedance spectrometry was modelled by using constant phase elements (CPEs). The bulk capacitance of the depletion region of the semiconductor and the capacitance of the Schottky contacts between electrodes and semiconductor contributed to the impedance spectra of the biochips. A linear pattern of response was determined with increasing bacteria concentration measured at test frequencies of 40 Hz, 400 Hz, and 4000 Hz. Nanotechnology is a major accelerator in the race for continuous device miniaturization and, naturally, bioelectric sensors could not be kept out of this progress. Janssen et al. [22] elaborate on the use of carbon nanotubes (CNTs) for improved sensitivity and response time as potential candidates for PoC protein detection, with the detection of bovine serum albumin (BSA) as a proof-of-concept application. Having a nanometer-scale diameter, CNTs are characterized by large surface and high electrical conductivity, which renders them ideal substrates for manufacturing bioelectric sensing element at the nanoscale. When considering a large, three-dimensional population of such conductive nanoelements interacting with biological moieties-such as antibodies-the systemic conductivity depends on the topological alignment of the nanoelements in this network. In other words, depending on the interaction between nanoelements such as CNTs and their immediate environment, including antibodies and target antigens (analytes in a sample), any disruption of the network continuity will result in a measurable increase in the network's electrical resistance. This effect is called electrical percolation. The authors applied this working principle to develop a CNT-based, bioelectrical percolation sensor for rapid (10 min) BSA determination with a limit of detection of 2.89 ng/mL and a linear response between 5 and 45 ng/mL. The biosensor was built upon a disposable cellulose paper strip impregnated with CNTs and antibodies for protein detection, the electrical resistance of which was measured with a programmed Arduino Uno. Application wise, one of the most intriguing and, at the same time, fascinating areas is the intercalation of bioelectric sensors with bioelectromagnetic medical interventions. Wound healing with the aid of external electric fields is such a case. Electrical simulation (ES) is one of the current electromagnetic therapeutic approaches to non-surgical wound healing. Lagoumintzis et al. [23] report on wireless micro current stimulation (WMCS), an alternative non-invasive and non-contact method to electrode-based ES. This approach utilizes the current-carrying capacity of charged air gas, based on the ability of nitrogen (N 2 ) and/or oxygen (O 2 ) molecules to accept or donate electrons, in order to distribute currents and voltages within the subject tissue. The authors applied an O 2 − -induced microcurrent of 1.5-4.0 µA intensity in the patient's body by using a device capable of producing a specific number of charged particles which covered the wound area from a distance of 12-15 cm. Clinical observations after a three-month treatment period demonstrated the considerable reduction of massive pressure ulcers and the formation of healthy new epithelial tissue. Immunohistochemical analysis revealed both a suppression of inflammation upon WMCS treatment, as well as an increase in myofibroblastic activity, collagen formation, mast cell existence, and a reduced granulocyte aggregation. In essence, the application of tandem WMCS sessions led to reverse the wound-associated electrical leak that short-circuits the skin and to restore the physiological electric fields and ionic currents of the affected tissues. The potential benefits of wide adoption of WMCS in clinical practice as a non-invasive, reagent-free method for wound healing is more than obvious. Bioelectric profiling is being rapidly established as a superior concept for several applications, including in vitro toxicity, signal transduction, real-time medical diagnostics, environmental risk assessment, and drug development. In the case of cancer, research in the field of hypoxia revealed how critical the pericellular oxygenation in a cell culture is. In this context, a critical marker for the monitoring the differentiation of cancer cells within a cell population is superoxide anion, which is mainly generated as a by-product of the oxidative phosphorylation by the electron transport chain of the mitochondria, is released to the mitochondrial matrix, where it is converted immediately to hydrogen peroxide. Mitochondrial hydrogen peroxide can then diffuse to the cytosol and the nucleus and react with other free radical species, alter signaling pathways or cause cellular damage. Along with other free radical species, superoxide has been found to mediate the development and/or survival of cancer cells and tumors, both in vivo and in vitro [24] [25] [26] . While hypoxia-regulated processes can result in the bad prognosis of conventional chemotherapy it is essential to monitor and control the cellular microenvironment. Mavrikou et al. [27] demonstrate an innovative and technologically disruptive approach for cell culture monitoring that can be used as an indicator for the response to different chemotherapy options. In particular, they investigated the accumulation of superoxide ions in cultured HeLa cervical cancer cells in response to different 5-fluorouracil (5-FU) concentrations. The anticancer activity of 5-FU emerges from the inhibition of thymidylate synthase (TS) activity during the S phase of the cell cycle and its incorporation into RNA and DNA of tumor cells, as well as from the generation mitochondrial ROS in the p53-dependent pathway [28] [29] [30] [31] [32] . Superoxide ion accumulation was monitored with the aid of an advanced bioelectric sensor based on Vero cells which were membrane-engineered with superoxide dismutase. As proven in several reports, the membrane potential of membrane-engineered Vero cell fibroblasts is affected by the interactions of electroinserted SOD molecules and superoxide anions, producing measurable changes in the membrane potential and can be used to determine superoxide extracellular accumulation, e.g., in association with in vitro neuronal differentiation. Therefore, by monitoring superoxide anion concentration in the culture medium after treatment with the chemotherapeutic agent, the authors were able to establish in a high throughput, non-invasive way the in vitro efficacy of 5-FU. This novel cell monitoring tool could be used for the accurate assessment of chemoresistance in cervical and other cancer cells, at least as far as its association with redox balance is concerned [33] [34] [35] . Within the same field of application and instead of measuring superoxide accumulation in cancer cells, Paivana et al. [36] opted for the direct assessment of the bioelectric properties of four different cancer cell lines (SK-N-SH, HEK293, HeLa and MCF-7) in response, once again, to 5-FU. Cancer cells were immobilized in calcium alginate matrix to mimic the natural tumor environment in vivo and cultured in different cell population densities (50,000 µL, 100,000 µL, and 200,000/100 µL). Bioelectric profiling was conducted by means of bioelectrical impedance-based measurements at three frequencies (1 KHz, 10 KHz, and 100 KHz). For impedance measurements, a voltage of 0.74 Vrms ± 50 mVrms was applied via the two terminals to the gold-coated electrodes. In this way, multi-dimensional mapping (cell line x population density x frequency) was achieved for the response of each cancer cell line against different 5-FU concentrations, in a rapid and entirely non-invasive way. It was demonstrated that bioimpedance measurements were highly correlated with standard cytotoxicity assays. This innovative bioimpedance profiling approach could enable the acquisition of a unique fingerprint for each cancer cell line response to a particular anticancer compound, therefore significantly accelerating the pace of chemotherapy drug screening. The final contribution by Ibrahim et al. [37] is the one more closely related to the title of this editorial; namely, the integration of bioelectric sensors in the IoT networks and their role in the ongoing Digital or Industrial Revolution 4.0. In their report, the authors deal with the advanced yet quite an issue of protection against cyberattacks on remote health monitoring systems. In recent years, these systems have experienced almost incredible growth and popularity mainly due to their wide availability as fitness/daily life components of wearables and associated apps. On a more strictly medicinal level, IoT implantable therapeutic equipment and networks (availing over more than one hundred medical tools) are becoming standard issues of modern medical practice. One solution to counter cyberattacks, including tampering, sniffing, and unauthorized access is the construction of attack graphs as a technique to determine risks and vulnerabilities within interoperable systems and to identify possible attack paths. For this purpose, the authors used the pacemaker automatic remote monitoring system (PARMS) as a model for developing tailor-made attack graphs. They illustrate life-threatening risks to patients presented by hacking into the pacemaker's system and the feasibility of protecting implantable medical devices (IMDs) [38] by carrying out security strategies completely on an external device called a shield. This is definitely a technological field with considerable growth perspectives. In conclusion, bioelectric sensors are here to stay in spite of their relatively recent emergence in diagnostic technology and related business. Without a doubt, they constitute an internal part of the wearables industry, which will keep on expanding in the next years. Bioelectric profiling is also becoming a valuable tool for rapid toxicity assays and compound x cell type fingerprinting, e.g., in the area of food safety control [10] . Innovative bioelectric sensors are being continuously developed to meet dire and yet unpreceded diagnostic and analytical needs; a vivid, very recent example is the expedient development of a cell-based bioelectric sensor for the ultra-sensitive detection of the SARS-CoV-2 S1 spike protein antigen in just three minutes [39] . As a final comment, bioelectric sensors may evolve as a separate scientific field themselves, opening new perspectives for a deeper understanding of bioelectric phenomena and their exploitation for practical purposes. One of the many possibilities in this direction is demonstrated by the new scientific topic of non-chemical distant cell interaction (NCDCI), where new principles of biology are being currently discovered in parallel with the development of innovative bioelectric sensing tools [40] . Bioelectrical impedance methods for non-invasive health monitoring: A review Sensors and Systems for Physical Rehabilitation and Health Monitoring-A Review Recent Progress in Flexible Wearable Sensors for Vital Sign Monitoring Impedimetric transducers based on interdigitated electrode arrays for bacterial detection-A review A review of the mitochondrial and glycolytic metabolism in human platelets and leukocytes: Implications for their use as bioenergetic biomarkers High-throughput assessment of oxidative respiration in fish embryos: Advancing adverse outcome pathways for mitochondrial dysfunction A Bioelectronic System to Measure the Glycolytic Metabolism of Activated CD4+ T Cells Modulating Alginate Hydrogels for Improved Biological Performance as Cellular 3D Microenvironments Pesticide residue screening using a novel artificial neural network combined with a bioelectric cellular biosensor Assessment of pesticides cytoxicity by means of bioelectric profiling of mammalian cells Visualization of the membrane engineering concept: Evidence for the specific orientation of electroinserted antibodies and selective binding of target analytes Split T7 RNA polymerase biosensors to study multiprotein interaction dynamics Inducible expression systems based on xenogeneic silencing and counter-silencing and design of a metabolic toggle switch Consumer Diagnostics. In Portable Biosensors and Point-of-Care Systems Commercialized point-of-care technologies A photoelectrochemical biosensor for rapid and ultrasensitive norovirus detection Beyond sensitive and selective electrochemical biosensors: Towards continuous, real-time, antibiofouling and calibration-free devices Skin-Integrated Wearable Systems and Implantable Biosensors: A Comprehensive Review Screen-Printed Electrodes: Promising Paper and Wearable Transducers for (Bio) Sensing Reflectance-Based Organic Pulse Meter Sensor for Wireless Monitoring of Photoplethysmogram Signal Junction-Based Si Biochips with Ring Electrodes for Novel Biosensing Applications Carbon Nanotube-Based Electrochemical Biosensor for Label-Free Protein Detection Wireless Direct Microampere Current in Wound Healing: Clinical and Immunohistological Data from Two Single Case Reports Involvement of glutathione peroxidases in the occurrence and development of breast cancers Tumor microenvironment: Extracellular matrix alterations influence tumor progression Targeting ROS-mediated crosstalk between autophagy and apoptosis in cancer Detection of Superoxide Alterations Induced by 5-Fluorouracil on HeLa Cells with a Cell-Based Biosensor 5-Fluorouracil incorporation into RNA and DNA in relation to thymidylate synthase inhibition of human colorectal cancers Capecitabine: A review Ferredoxin reductase affects p53-dependent, 5-fluorouracil-induced apoptosis in colorectal cancer cells Selenocystine potentiates cancer cell apoptosis induced by 5-fluorouracil by triggering reactive oxygen species-mediated DNA damage and inactivation of the ERK pathway. Free Radic Sanguisorba officinalis L. synergistically enhanced 5-fluorouracil cytotoxicity in colorectal cancer cells by promoting a reactive oxygen species-mediated, mitochondria-caspase-dependent apoptotic pathway Cisplatin resistance in human cervical, ovarian and lung cancer cells Cancer drug resistance: Redox resetting renders a way Targeting cancer stem cell redox metabolism to enhance therapy responses Bioelectrical Analysis of Various Cancer Cell Types Immobilized in 3D Matrix and Cultured in 3D-Printed Well Attack Graph Modeling for Implantable Pacemaker They can Hear Your Heartbeats: Non-Invasive Security for Implantable Medical Devices Development of a Portable, Ultra-Rapid and Ultra-Sensitive Cell-Based Biosensor for the Direct Detection of the SARS-CoV-2 S1 Spike Protein Antigen Cell-to-Cell Communication: Evidence of Near-Instantaneous Distant, Non-Chemical Communication between Neuronal (Human SK-N-SH Neuroblastoma) Cells by Using a Novel Bioelectric Biosensor