key: cord-0768689-bbtwinrv authors: Bellgardt, Martin; Özcelik, Dennis; Breuer-Kaiser, Andreas Friedrich Christoph; Steinfort, Claudia; Breuer, Thomas Georg Karl; Weber, Thomas Peter; Herzog-Niescery, Jennifer title: Extracorporeal membrane oxygenation and inhaled sedation in coronavirus disease 2019-related acute respiratory distress syndrome date: 2021-11-09 journal: World J Crit Care Med DOI: 10.5492/wjccm.v10.i6.323 sha: 91effd62f4d9e6f5c5cef0bcc4750a00e9b5e7ef doc_id: 768689 cord_uid: bbtwinrv Coronavirus disease 2019 (COVID-19) related acute respiratory distress syndrome (ARDS) is a severe complication of infection with severe acute respiratory syndrome coronavirus 2, and the primary cause of death in the current pandemic. Critically ill patients often undergo extracorporeal membrane oxygenation (ECMO) therapy as the last resort over an extended period. ECMO therapy requires sedation of the patient, which is usually achieved by intravenous administration of sedatives. The shortage of intravenous sedative drugs due to the ongoing pandemic, and attempts to improve treatment outcome for COVID-19 patients, drove the application of inhaled sedation as a promising alternative for sedation during ECMO therapy. Administration of volatile anesthetics requires an appropriate delivery. Commercially available ones are the anesthetic gas reflection systems AnaConDa(® )and MIRUS(TM), and each should be combined with a gas scavenging system. In this review, we describe respiratory management in COVID-19 patients and the procedures for inhaled sedation during ECMO therapy of COVID-19 related ARDS. We focus particularly on the technical details of administration of volatile anesthetics. Furthermore, we describe the advantages of inhaled sedation and volatile anesthetics, and we discuss the limitations as well as the requirements for safe application in the clinical setting. The ongoing pandemic is caused by the severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) that triggers a variety of symptoms in the human host. One major complication of infection with SARS-CoV-2 is the acute respiratory distress syndrome (ARDS). Coronavirus disease 2019 (COVID-19) related ARDS is a severe condition associated with high mortality and is the primary cause of death among COVID-19 patients. Treatment of this condition is mainly supportive and requires considerable resources, but effective coordination enables the health care system to cope with the influx of critically ill patients [1] . If respiratory failure occurs in COVID-19 patients despite all efforts, extracorporeal membrane oxygenation (ECMO) treatment over an extended period is the last remaining therapeutic option [2] . Since the outcome of this treatment is poor, better prevention and treatment are urgently needed. ECMO therapy requires sedation of the patient, often via high doses of intravenous sedatives such as midazolam, ketamine, or propofol in combination with an opioid and neuromuscular blocking agent. The ongoing pandemic is exhausting supplies of these drugs, so alternative approaches have to be considered [3] . One practical alternative approach is inhaled sedation with volatile anesthetics, such as isoflurane, sevoflurane, or desflurane [4, 5] . Beside the low costs, volatile anesthetics are associated with faster onset and offset of sedation and thus allow efficient control of administration. Application of these drugs does not rely on electronic infusion pumps, which have become scarce during the pandemic. In addition, volatile anesthetics cause fewer hallucinations and lower opioid needs than intravenous anesthetics. Moreover, a recent study suggests that inhaled sedation could be associated with a better outcome than intravenous sedation [6] . In particular, sevoflurane yielded superior outcomes than other anesthetics [7, 8] . Nonetheless, the application of inhaled sedation faces limitations. Most critical care units lack proper delivery and gas scavenging systems for limiting pollution with volatile anesthetics [9] . Further, health care professionals require special training to administer appropriately the anesthetics and to recognize contraindications, such as malignant hyperthermia. In this review, we summarize the requirements for inhaled sedation in COVID-19 patients under ECMO therapy, and we highlight the technical aspects of administration of volatile anesthetics. Continuous monitoring of oxygen saturation in the patient is necessary, since a drop in saturation indicates a severe progression of COVID-19. If oxygen levels fall, respiratory management is required, but spontaneous breathing should be maintained as long as possible and reasonable. A number of approaches to support spontaneous breathing is available and has been comprehensively summarized elsewhere [10] . A schematic overview of the strategy for respiratory management in COVID-19 patients is presented in Figure 1 . The use of nasal cannula is the first method of choice; however, the fraction of inspired oxygen (FiO 2 ) is limited to 0.3 to 0.4. If insufficient, high flow nasal cannula produces a high flow and continuous positive airway pressure, capable of achieving higher FiO 2 . This can be further supported by shifting the patient in a prone position [11] . The last resort of noninvasive intervention for respiratory management is the use of bilevel positive airway pressure and pressure support ventilation. These measures are capable of providing high FiO 2 and can be combined with placing the patient in prone position for further support. It should be mentioned that these measures require high quality masks for respiration to prevent pressure injuries on the skin or the nose of the patient. Severe hypoxia, which is associated with COVID-19 related ARDS, impairs consciousness, vigilance, or compliance. For instance, impaired compliance of the patient can hinder the use of facial masks, leading to a dramatic drop in oxygen saturation. Consequently, severe hypoxia requires invasive measures, e.g., endotracheal intubation. The decision to initiate this invasive intervention has to be made with the patient, or the relatives if necessary, and requires an open discussion on respiratory management. After intubation, a bronchoscopy or a thoracic drainage system should be considered, and the patient should be placed in prone position to support breathing. The specific type of invasive intervention depends on ventilation pressure and lung compliance. If the partial pressure of oxygen/FiO 2 ratio drops below 150 mmHg, the patient should be placed in prone position for more than 12 h [12] . Individual measures can be taken to manage severe hypoxia, such as application of inhaled nitric oxide, muscle relaxants, or recruitment maneuver. If respiratory function remains poor (i.e. lower than 20 mL/mbar, partial pressure of oxygen/FiO 2 ratio less than 80 mmHg, or pH less than 7.25) despite prone positioning, veno-venous ECMO is the last resort to save the life of the patient [13, 14] . Deploying an ECMO system can only be considered if all other approaches are unsuccessful and if there are no contraindications [15] . ECMO therapy can cause adverse events and suboptimal responses, in particular in COVID-19 patients who are predisposed to bleeding and thrombotic complications [16] . Such events could suggest withdrawal of ECMO therapy. Furthermore, a recent study reported an in-hospital mortality of 37.4% for patients with severe COVID-19 related ARDS 90 d after the initiation of ECMO therapy [17] . This highlights the importance of an open discussion with the patient and relatives at an early stage in order to clarify treatment goals, expectations, and possible outcomes as well as to obtain consent from the patient regarding continuation or discontinuation of therapy [18] . During ECMO therapy, patients with ARDS in prone position should be kept in at least light sedation, corresponding to a Richmond Agitation-Sedation Scale of ≥ 2[12]. Sedation is associated with side effects such as delirium, respiratory depression, and immunosuppression. Further, deep sedation is a risk factor for COVID-19 patients and is associated with poorer outcome. Thus, sedation must be monitored carefully. Processed electroencephalogram monitoring is a very useful approach to assess anesthesia and to recognize burst suppression. In case of inhaled sedation, measurement of the end-tidal gas concentration or the corresponding minimum alveolar concentration is a recommended approach. If Richmond Agitation-Sedation Scale increases during ECMO therapy, intravenous sedation is necessary to stabilize the depth of sedation. The prerequisite for using the Anaesthetic Conserving Device (ACD) AnaConDa ® (Sedana Medical AB, Danderyd, Sweden) or the MIRUS TM system (TIM, Koblenz, Germany) depends on several clinical parameters (see Figure 1 ). If lung compliance is acceptable, and CO 2 can be reduced sufficiently, both types of systems are able to maintain spontaneous breathing [19] [20] [21] . However, if lung compliance is poor, reduction of dead space and active humidification is necessary, which can be facilitated by inhaled sedation via a circle breathing system [22, 23] . The AnaConDa ® system is capable of achieving adequate sedation with isoflurane or sevoflurane. In addition to isoflurane and sevoflurane, the MIRUS system can also apply desflurane. The pathophysiological basis for COVID-19 related ARDS is the altered blood-air barrier. The diffusion distance for adequate gas exchange in the lung alveoli is impaired by inflammation, edema, and accumulated mucus. These impairments severely limit O 2 uptake and CO 2 release. However, volatile anesthetics are still able to establish an effective concentration in the blood stream under ARDS conditions, provided the necessary concentration gradient is maintained [24, 25] . Volatile anesthetics show superior diffusion properties than O 2 and CO 2 , which can be attributed to the lipophilic nature of the anesthetic gas. Only if both the tubus and the bronchial system are completely clogged, intravenous sedation is necessary. The ECMO system itself can be used for administration of volatile anesthetics [26, 27] . This requires installation of a vaporizer into the oxygen tube and connection of a pipe for exhaust gas removal to the outlet and the negative pressure device. The inhaled and exhaled portion of the anesthetic gas must be carefully monitored in order to determine the depth of sedation and to detect possible leakage. Since leakage can easily lead to pollution of the intensive care unit (ICU), a proper scavenging system is crucial. Nonetheless, it must be noted that these scavengers can create high back pressure that increases the risk for gas embolism. Another important technical aspect to take into consideration is the type of membrane oxygenator. Transmembrane passage of the anesthetic gas is facilitated only via hollowfiber membrane oxygenators, which are made of polypropylene. If the oxygenators are made of poly(4methyl-1pentene), they do not permit transmembrane passage. In this case, volatile anesthetics have to be administered via an anesthetic gas reflection system. One major anesthetic gas reflection system is the AnaConDa ® system, which is commercially available as a larger version, i.e. ACD-100, and a smaller version, i.e. ACD-50 (which is also known as AnaConDa ® -S) (Figure 2) . The other major gas reflection system is the MIRUS TM system (Figures 3 and 4) . Recent studies showed that the AnaConDa ® systems can be used successfully for sedation of ARDS patients during ECMO therapy [20, 28, 29] . Similarly, a study using the MIRUS TM system demonstrated successful application of inhaled sedation for ECMO therapy in patients with COVID-19 related ARDS [30] . The CO 2 signal has no effect on the performance; nonetheless, a CO 2 pressure of at least 10 mmHg is an indication for an open and managed airway and is associated with a higher survival rate [31, 32] . Consequently, the authors call for a minimum of 10 mmHg as standard for the AnaConDa ® system. If this minimum cannot be maintained by adjusting the ventilation, the level of sedation must be monitored carefully and, if necessary, complemented by intravenous sedation of the patient. November 9, 2021 Volume 10 Issue 6 By contrast, the MIRUS TM system requires an end-tidal CO 2 pressure of at least 15 mmHg. If the end-tidal CO 2 pressure drops below 12 mmHg, the MIRUS TM system stops administering the anesthetic, indicated by a red alert. This could result in the inadvertent awakening of the patient, which would then require intravenous sedation to restore anesthesia. The most recent MIRUS TM systems (starting from version 2.0 onward) indicate a tidal volume of less than 200 mL by a yellow alert ( Figure 5 ). During ECMO therapy, the minimum respiratory minute volume falls frequently below the minimum tidal volume of the MIRUS TM system. The yellow alert can be acknowledged in order to continue administration; however, this procedure is associated with the risk of overdosing with the anesthetic. In case of isoflurane, the MIRUS TM system displays a higher gas concentration under ECMO therapy. Hence, a concentration of more than 2% can be displayed, although it does not correspond to the actual end-tidal values. Because higher effective concentrations are required for the same MAC with sevoflurane and desflurane, this effect is not as pronounced with these gases. Nevertheless, the operator should choose the lowest wash-in speed (i.e. the setting "tortoise") for all of three anesthetics isoflurane, sevoflurane, and desflurane ( Figure 5 ). An important consideration for the application of anesthetic gas reflection systems is the volume of a breath that does not participate in gas exchange, i.e. the dead space. The volumetric dead space of the MIRUS TM system is 100 mL [19] , whereas the volumetric dead space for the AnaConDa ® system ACD-100 is 100 mL and 50 mL for the ACD-50 [23] . However, the ECMO system eliminates CO 2 effectively. Thus, volumetric and reflective dead space of the anesthetic gas reflection systems are irrelevant for ECMO therapy. Another alternative device for administration of volatile anesthetics is the circle breathing system. Usage of this system has been reported during the ongoing SARS-CoV-2 pandemic. However, to the best of our knowledge, the deployment of a circle breathing system in conjunction of ECMO therapy in the ICU has not been described in literature. The SARS-CoV-2 pandemic is estimated to be one of the most expensive natural disasters in recorded history [33] . Besides economic repercussions due to the containment measures, adequate treatment of patients causes a substantial financial strain for the global health care systems. ECMO, in particular, is a very expensive procedure, and thus the reduction of associated costs is highly desirable. Treatment of COVID-19 related ARDS requires larger amounts of sedatives than treatment of non-COVID-19 patients. Consequently, treatment of COVID-19 patients, who undergo November 9, 2021 Volume 10 Issue 6 Figure 5 Display of the MIRUS TM controller. Yellow alarm refers to a low tidal volume. In this case, the wash-in speed "tortoise" should be selected. invasive mechanical ventilation without ECMO therapy, demands a large consumption of anesthetics. However, administration of volatile anesthetics with the AnaConDa ® systems ACD-100 or ACD-50 during ECMO therapy is very cost-effective, as the low respiratory minute volume yields a usage of only 1 mL/h to 3 mL/h. The consumption of volatile anesthetics by the MIRUS TM system is in a comparable range and is estimated to be 3 mL/h to 5 mL/h (unpublished data). Besides consumption, a certain amount of anesthetic gas is lost in the delivery system, i.e. at the exhalation outlet of the ventilator or at the oxygenator of the ECMO device. The exhalation outlet has the advantage that the gas flow can conduct viral particles and hence reduces the risk of infection for the health care personnel [34, 35] . The oxygenator was used initially for intraoperative delivery of the anesthetic gas but modern reflection systems require containment of volatile anesthetics. For instance, the oxygenator of the Cardiohelp System (Getinge Group, Gothenburg, Sweden) does not leak anesthetic gas, according to the manufacturer and independent researchers [26] . While the loss of anesthetic gas via the oxygenator is theoretically still possible, instruments in the ICUs usually lack such device. Respiratory management has also to take into account the SARS-CoV-2 infection. Hence, tracheotomy is often avoided if the patient shows a high viral load. Nevertheless, tracheostomy is suggested to improve the outcome of COVID-19 patients, in particular, if the intervention is performed between day 13 and day 17 post intubation [36] . The handling of medical devices and instruments requires strict hygiene measures. Firstly, a closed suction system is mandatory (Figures 2 and 3) . Secondly, the tube has to be clamped off prior to disconnect it from heat and moisture exchanger filters. Here, the MIRUS TM system has an advantage since the heat and moisture exchanger filters are integrated in the device, so that the controller and measuring units remain in a clean and safe distance. By contrast, the AnaConDa ® systems measure the concentration of the anesthetics in close proximity to the patient and hence are exposed to a high risk of contamination. However, the water trap at the gas monitor is sealed, which prevents intrusion of viral pathogens. In order to connect either the MIRUS TM or the AnaConDa ® system to the vacuum connection on the ICUs, a suitable gas flow conduction system is required. The CleanAir TM system (TIM, Koblenz, Germany) is recommended for gas flow conduction, because it is independent of the reflector (Figure 6 ). It operates well under vacuum, is sealed off the environment, and thus eliminates the risk of disseminating viral particles in the air [35] . November 9, 2021 Volume 10 Issue 6 The use of volatile anesthetics is beneficial for the treatment of patients with SARS-CoV-2 infection, but the exposure of health care professionals to waste anesthetic gas is a concern. Poor air-conditioning in ICUs and inconsistent international limits for anesthetic gas concentrations amplify the problem. The United States National Institute of Occupational Safety and Health defined an exposure limit of 2 ppm for isoflurane, sevoflurane, and desflurane, but other countries use higher exposure limits [35, 38] . Most studies on air pollution report gas concentrations of less than 2 ppm while using MIRUS TM or AnaConDa ® systems in mechanically ventilated patients; nonetheless, these studies use an air-conditioning system with at least six air exchanges per hour and a scavenging system (e.g., vacuum-based open reservoir gas scavenging systems or adsorbers with activated charcoal)[35, 38, 39] . To the best of our knowledge, there are no studies focusing on occupational gas exposure by inhalational sedation in patients undergoing ECMO therapy. Nevertheless, Meiser and colleagues observed that gas consumption during isoflurane sedation via AnaConDa ® was exceptionally low, and they concluded that the sweep gas of the oxygenator did not contain the volatile anesthetic [20] . Our group measured the air pollution using photoacoustic gas monitoring in a similar setting (single room, isoflurane via AnaConDa ® , vacuum-based scavenging system, air-conditioning with 11 air exchanges per hour) and detected concentrations of approximately 0.5 ppm to 2 ppm (unpublished data). Obviously, a proper application of all systems must be ensured as well as "good workplace practice", including leak testing of the respirator and training of health care professionals. The conformity between the applied systems and respirators is of particular importance, as problems may occur even without active suction. ECMO therapy is associated with high mortality and hence is deemed as the last resort after all other possible interventions failed. In case of COVID-19 related ARDS, the mortality 90 d post ECMO initiation is very high [17] . Besides the high mortality, ECMO therapy is also associated with a number of long-term effects, which are known from ICU survivors. Postintensive care syndrome describes the impairments in physical function as well as cognitive and mental health that ICU survivors experience. The aftermaths of influenza A H1N1 or SARS showed that this syndrome can persist for years and hamper recovery [40] . In addition, a substantial portion of ICU survivors suffers from post-traumatic stress disorder. The data on ECMO survivors is sparse, but a limited number of studies demonstrated that these patients show impaired recovery, chronic pain, and mental illness, including post-traumatic stress disorder for up to 3 years after hospitalization [41] [42] [43] [44] . Only very few studies suggest that ECMO treatment had no effect on ARDS patients after initiation of therapy [45] . Consequently, the authors of this article emphasize that indication for ECMO therapy must considered very carefully. The application of inhaled sedation for ECMO treatment has a number of advantages. For instance, the supply of volatile anesthetics is currently not limited, in contrast to intravenous anesthetics. Volatile anesthetics are also less hallucinogenic, and patients require less opiates during inhaled sedation than during intravenous sedation. If applied properly, volatile anesthetics allow easier control of the depth of sedation of the patient, even if gas exchange is severely limited by COVID-19 related ARDS. Furthermore, the volumetric and reflective dead space of the delivery systems as well as CO 2 retention are negligible for ECMO therapy. So far, few studies reported the successful application of isoflurane and sevoflurane for ECMO therapy[6-8]. The application of volatile anesthetics depends on adequate delivery and gas scavenging systems, which are not established in all ICUs[9]; however, the lack of electronic infusion pumps for intravenous sedatives due to the SARS-CoV-2 pandemic could be an incentive to equip ICUs with such hardware. Currently, the application of volatile anesthetics for inhaled sedation during ECMO treatment is still not widely established. Consequently, the health care personnel lacks the adequate training for application of this procedure as well as for recognizing contraindications of which malignant hyperthermia is the most notable one. November 9, 2021 Volume 10 Issue 6 Figure 6 Example of a vacuum-based gas scavenging system (CleanAir TM system). 1 Expiration port of the ventilator; 2 Open reservoir scavenging system; 3 Vacuum line. In COVID-19 related ARDS, inhaled sedation demonstrated many advantages, including spontaneous breathing and deep sedation in prone position. Inhaled sedation also allows safe monitoring of sedation depth via measurement of the anesthetic gas. In addition, veno-venous ECMO avoids problems concerning dead space and CO 2 increase, as sometimes seen during inhaled sedation via AnaConDa ® or MIRUS TM . Further, inhaled sedation allows administration of isoflurane, which shows favorable properties, especially in light of the shortage of intravenous sedatives. This procedure, however, requires preparation and training. Hence, medical professionals should use the time of moderate occupancy rates in the ICUs accordingly. Critical care response to a hospital outbreak of the 2019-nCoV infection in Shenzhen Extra Corporeal Membrane Oxygenation (ECMO) review of a lifesaving technology Six-Month Survival After Extracorporeal Membrane Oxygenation for Severe COVID-19 Veno-venous extracorporeal membrane oxygenation allocation in the COVID-19 pandemic COVID-19 and its implications for thrombosis and anticoagulation Extracorporeal Life Support Organization. Extracorporeal membrane oxygenation support in COVID-19: an international cohort study of the Extracorporeal Life Support Organization registry Rationing in the intensive care unit: to disclose or disguise? Use of the MIRUS™ system for general anaesthesia during surgery: a comparison of isoflurane, sevoflurane and desflurane Inhaled Sedation in Patients With Acute Respiratory Distress Syndrome Undergoing Extracorporeal Membrane Oxygenation Inhalation Sedation in Subjects With ARDS Undergoing Continuous Lateral Rotational Therapy The anesthetic conserving device compared with conventional circle system used under different flow conditions for inhaled anesthesia A technical review of the history, development and performance of the anaesthetic conserving device "AnaConDa" for delivering volatile anaesthetic in intensive and postoperative critical care High risk of intraoperative awareness during cardiopulmonary bypass with isoflurane administration via diffusion membrane oxygenators Tricks, tips, and literature review on the adapted vaporize system to deliver volatile agents during cardiopulmonary bypass Isoflurane Sedation in Patients Undergoing Venoarterial Extracorporeal Membrane Oxygenation Treatment for Cardiogenic Shock-An Observational Propensity-Matched Study Inhalative sedation with small tidal volumes under venovenous ECMO Volatile Isoflurane in Critically Ill Coronavirus Disease 2019 Patients-A Case Series and Systematic Review Monitoring Exhaled Carbon Dioxide The COVID-19 Pandemic and the $16 Trillion Virus Inhaled anesthetic agent sedation in the ICU and trace gas concentrations: a review Environmental safety: Air pollution while using MIRUS™ for short-term sedation in the ICU In vivo uptake and elimination of isoflurane by different membrane oxygenators during cardiopulmonary bypass Timing of Tracheostomy for Prolonged Respiratory Wean in Critically Ill Coronavirus Disease 2019 Patients: A Machine Learning Approach National Institute of Occupational Safety and Health. NIOSH Pocket Guide to Chemical Hazards Health worker exposure risk during inhalation sedation with sevoflurane using the (AnaConDa®) anaesthetic conserving device Prolonged isoflurane sedation of intensive care unit patients with the Anesthetic Conserving Device Rove JY; the Outcomes and Recovery After COVID-19 Leading to ECMO (ORACLE) Group. Long-term recovery of survivors of coronavirus disease (COVID-19) treated with extracorporeal membrane oxygenation: The next imperative Long-Term Survival, Posttraumatic Stress, and Quality of Life post Extracorporeal Membrane Oxygenation Health-related quality of life. Long-term survival in patients with ARDS following extracorporeal membrane oxygenation (ECMO) Long-Term Survival and Health-Related Quality of Life in Adults After Extra Corporeal Membrane Oxygenation Cognitive, mood and quality of life impairments in a select population of ARDS survivors