key: cord-0790919-hvap5r3b authors: Meinhart, Florian; Stütz, Thomas; Sareban, Mahdi; Kulnik, Stefan Tino; Niebauer, Josef title: Mobile Technologies to Promote Physical Activity during Cardiac Rehabilitation: A Scoping Review date: 2020-12-24 journal: Sensors (Basel) DOI: 10.3390/s21010065 sha: ce04593e0acd295a750d12d0ece996a4f9eb934f doc_id: 790919 cord_uid: hvap5r3b Promoting regular physical activity (PA) and improving exercise capacity are the primary goals of cardiac rehabilitation (CR). Mobile technologies (mTechs) like smartphones, smartwatches, and fitness trackers might help patients in reaching these goals. This review aimed to scope current scientific literature on mTechs in CR to assess the impact on patients’ exercise capacity and to identify gaps and future directions for research. PubMed, CENTRAL, and CDSR were systematically searched for randomized controlled trials (RCTs). These RCTs had to utilize mTechs to objectively monitor and promote PA of patients during or following CR, aim at improvements in exercise capacity, and be published between December 2014 and December 2019. A total of 964 publications were identified, and 13 studies met all inclusion criteria. Home-based CR with mTechs vs. outpatient CR without mTechs and outpatient CR with mTechs vs. outpatient CR without mTechs did not lead to statistically significant differences in exercise capacity. In contrast, outpatient CR followed by home-based CR with mTechs led to significant improvement in exercise capacity as compared to outpatient CR without further formal CR. Supplying patients with mTechs may improve exercise capacity. To ensure that usage of and compliance with mTechs is optimal, a concentrated effort of CR staff has to be achieved. The COVID-19 pandemic has led to an unprecedented lack of patient support while away from institutional CR. Even though mTechs lend themselves as suitable assistants, evidence is lacking that they can fill this gap. Cardiovascular diseases (CVDs) present the leading cause of death worldwide [1] , and prevalence and costs will continue to rise [2] . Increasing the level of physical activity (PA) and subsequently exercise capacity is an effective prevention strategy to limit the growing burden of CVD [3, 4] . Indeed, it has been shown that risk of mortality is dramatically lower for people who meet WHO recommendations of at least 150 min of moderate-intensity or at least 75 min of vigorous-intensity aerobic PA per week [3, 5] . Therefore, increasing the level of PA has become a cornerstone of cardiac rehabilitation (CR) and an integral and comprehensive component in the continuum of care for patients with CVD [6] . CR can be offered as a facility-based (inpatient and/or outpatient) as well as a home-based program [6] . Unfortunately, once CR has ended, patients often do not maintain healthy lifestyle changes [7, 8] . Novel strategies that increase PA by achieving sustainable health behavior change are urgently needed. Mobile technologies (mTechs) based on smartphones, smartwatches, and fitness trackers hold promise to deliver successful solutions by enabling objective PA monitoring. Objective monitoring yields several advantages over self-reported PA monitoring, such as detailed information regarding type, intensity, and volume [9] . Indeed, self-reports of PA are susceptible to several sources of bias, including misperception, recall bias, or exaggeration due to social desirability bias [10, 11] . Moreover, reporting and analyzing self-reported PA is time-consuming. Objective PA monitoring is preferable because it paves the road for the application of behavioral change techniques (BCTs). BCTs are a mainstay of sustainable health behavior change. Thus, objective PA monitoring combined with BCTs facilitates meeting PA targets following CR. Several recent studies with CVD patients employed objective PA measurements [12] [13] [14] [15] [16] [17] [18] [19] [20] [21] in facility-based CR and home-based CR. Home-based CR is also referred to as telerehabilitation. As CR facilities were closed during the initial phase of the current COVID-19 crisis, dramatic shifts towards home-based CR have been observed and are expected to persist not only in the research setting but also during standard CR [22] . To our knowledge, there is no review with a focus on objective mTechs-assisted PA monitoring and promotion in the context of CR. This scoping review aims to review recently published randomized controlled trials (RCTs) that employ mTechs for objective monitoring of PA on patients' exercise capacity during or following CR. Further, we assess in which application contexts which mTechs were used and whether/which BCTs were employed to promote PA. Finally, we identify research gaps and future research directions concerning mTechs for objective monitoring and the promotion of PA for CVD patients. Overall, this review has the objective to support the design and development of novel mTech-based CR interventions. We conducted a scoping review [23, 24] , which followed the guidelines of the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) extension for scoping reviews [25] . No study protocol was registered. A scoping review is the preferred approach for identifying available research literature and mapping current evidence and research gaps [23, 24] . This scoping review aims to give researchers of novel mTech interventions for CR an overview of the state-of-the-art. Eligibility criteria were selected to provide an overview of the application and potential of mTechs during and after CR, primarily focusing on objective PA monitoring to promote increased PA, and to assess the potential improvement in exercise capacity. The focus on objective PA monitoring is motivated by the importance of PA for CR and the short-comings of self-reports [9] . We defined the following eligibility criteria for studies based on the PICOS (patients, interventions, comparisons, outcomes, study design) approach [26] . Patients were required to be patients with CVD during or following CR with no further restrictions. Interventions needed to include mTechs for objective PA monitoring to promote PA during or after CR. Note that throughout this article the term "intervention" is used exclusively to refer to interventions that employed mTechs in CR. Studies in which objective PA monitoring was not used to promote PA explicitly, but only for data collection without being used for patient feedback interaction, were excluded. Comparisons were made between intervention groups using mTechs for objective PA monitoring and promotion (IG) and control groups (CGs) that did not use mTechs. Outcomes of included studies evaluated at least one objective measure of exercise capacity, e.g., peak oxygen consumption (VO 2peak ) measured with a medical device in a laboratory setting. The rationale for this criterion is that exercise capacity is a robust measure of PA and a strong predictor of all-cause and cardiovascular mortality [27, 28] . Study designs were restricted to randomized controlled trials (RCTs) with no restrictions on follow-up duration or sample size in order to maximize the number of eligible studies. Articles had to be available in English or German. In order to scope current mTechs, the search was limited to studies published between December 2014 and December 2019. Additionally, reference sections of related reviews were searched for relevant studies. Two authors (FM, STK) independently searched PubMed, Cochrane Central Register of Controlled Trials (CENTRAL), and Cochrane Database of Systematic Reviews (CDSR). The search strategy combined search terms around the three topics (CVD, PA, and mTechs) with the operator AND. Box 1 shows the search strategy for PubMed. MeSH terms were used where appropriate, e.g., the MeSH term "exercise". Two authors (FM, STK) independently screened titles and abstracts of the studies identified with the abovementioned search strategy. The full text of the study was analyzed if the title and abstract did not provide sufficient information to confirm eligibility. One author (FM) extracted data of the included studies in a tabular form by using Microsoft Excel. All publicly available material on the studies was used for data extraction, including online supplemental files and information provided in online trial registers (e.g., ClinicalTrials.gov). The categories (column headers) for extracted data comprised study title, year, keywords, aims and objectives, conclusions, digital technology used for objective PA measurement, BCTs, theories and strategies for behavior change, intervention description, evaluation, study design, patients, duration, outcome measures, clinical trial registration, summary of results, discussion, limitations, reported future challenges, and recommendations, as well as additional notes. Data on BCTs and theories and strategies for behavior change were extracted to investigate whether specific underlying theories of behavior change were mentioned in the articles, and whether the studies used specific taxonomies of BCTs, such as those proposed by Michie et al. [29] . Studies were grouped and summarized according to aspects of the study aims, i.e., when and how mTechs were applied during and after CR, the effect of interventions with mTechs on patients' exercise capacity, which mTechs were used and whether/which BCTs were employed to promote PA. Figure 1 shows the study selection process utilizing the PRISMA flow diagram [26] . The electronic search yielded 362 records in PubMed and 577 records in CENTRAL. The search in CDSR and screening of references of relevant review articles resulted in the inclusion of additional 25 records. Based on information in titles and abstracts, we excluded 859 articles because it was evident that eligibility criteria were not met. After removing duplicates, 92 articles were selected for full-text assessment, and all articles but one were available in English or German. Finally, full-text assessment led to the exclusion of 79 more articles; for details see Figure 1 . Hence, we identified 13 articles meeting all criteria for eligibility. dations, as well as additional notes. Data on BCTs and theories and strategies for behavior change were extracted to investigate whether specific underlying theories of behavior change were mentioned in the articles, and whether the studies used specific taxonomies of BCTs, such as those proposed by Michie et al. [29] . Studies were grouped and summarized according to aspects of the study aims, i.e., when and how mTechs were applied during and after CR, the effect of interventions with mTechs on patients' exercise capacity, which mTechs were used and whether/which BCTs were employed to promote PA. Figure 1 shows the study selection process utilizing the PRISMA flow diagram [26] . The electronic search yielded 362 records in PubMed and 577 records in CENTRAL. The search in CDSR and screening of references of relevant review articles resulted in the inclusion of additional 25 records. Based on information in titles and abstracts, we excluded 859 articles because it was evident that eligibility criteria were not met. After removing duplicates, 92 articles were selected for full-text assessment, and all articles but one were available in English or German. Finally, full-text assessment led to the exclusion of 79 more articles; for details see Figure 1 . Hence, we identified 13 articles meeting all criteria for eligibility. In the selected studies, objective PA monitoring with mTechs was performed for either one of the following three situations: during home-based CR; as an adjunct during an outpatient CR; or during home-based continuation of CR after completion of an outpatient CR. CR using mTechs was compared to outpatient CR without mTechs and no formal CR following outpatient CR. In the studies, 15 distinct group comparisons were presented, and three classes of group comparisons were identified: (a) Home-based CR with mTechs (IG) vs. outpatient CR without mTechs (CG) (n = 3); (b) Outpatient CR with mTechs (IG) vs. outpatient CR without mTechs (CG) (n = 2); (c) Outpatient CR followed by home-based CR with mTechs (IG) vs. outpatient CR without further CR (CG) (n = 10). Table 1 summarizes the study objectives and the characteristics of patients per group. All study objectives included the evaluation of effects of CR with mTechs on patient health outcomes. The number of randomized patients in the included studies (n = 1977) ranged from 32 [14] to 850 [30] . The mean age in groups ranged from 54 years [12] to 67 years [14] . Mean patient age was not reported in one study [31] . Gender was highly imbalanced in the recruited patients. All studies included more male than female patients, and in one study, not a single patient was female [32] . On average, 14% percent of study patients were female. There were 229 dropouts (12%) in total, with a range from 0% in a CG [13] to 65% in an IG [17] . One study did not report the number of dropouts [31] . The number of dropouts was larger in IG with mTechs compared to the CG without mTechs in 9 of the 15 group comparisons (study by Vogel [32] counted twice as the same groups underwent outpatient CR with vs. without mTechs and home-based CR with mTechs vs. no formal CR). In three cases, the number of dropouts was smaller; it was equal in two cases, and not reported in one case. Table 2 summarizes the effect on exercise capacity, study duration, total number of patients, and outcome measure for exercise capacity. The studies lasted from six weeks [13, 20, 21, 31, 33 ] to 24 weeks [16, 17] . Nine studies had an exercise capacity related measure as the primary outcome. In the remaining four studies [19, [30] [31] [32] , exercise capacity was a secondary outcome. Ten studies [12] [13] [14] [15] [16] [17] [18] [19] [20] [21] used peak oxygen consumption (VO 2peak ) as a measure for exercise capacity. Two studies [31, 33] assessed the exercise capacity utilizing a six-minute walk test (6MWT). One study [32] used the peak power output during cycle ergometry (Peak W). Two studies [12, 30] reported the improvements in exercise capacity for bothVO 2peak as well as 6MWT outcomes. [14] 12 w n = 32VO 2peak ↑ ↓ ↑ Fang et al. [33] 6 w n = 80 6MWT ↑ ↑ ↑ Frederix et al. [15] 18 Three studies [13, 20, 21] compared mTechs during home-based CR to outpatient CR without mTechs with a total of 297 patients. The studies had a duration of six weeks and employedVO 2peak as an outcome measure. Two studies showed no statistically significant differences in the outcomes [13, 20] , and one study explicitly showed non-inferiority of the home-based CR with mTechs [21] . Two studies [31, 32] used mTechs as adjunct during an outpatient CR (n = 102). Study duration was 6 and 12 weeks, and outcome measures were Peak W and 6MTW, respectively. Neither study showed statistically significant improvements in exercise capacity through the use of mTechs. 3.5. Effects on Exercise Capacity: Outpatient CR followed by mTechs during Home-Based CR vs. Outpatient CR without Further CR Ten of the studies [12] [13] [14] [15] [16] [17] [18] [19] 32, 33] compared a CG of outpatient CR without further CR to outpatient CR followed by mTechs during home-based CR (total n = 1659). Study duration ranged from 6 to 24 weeks. Most of the studies employedVO 2peak as an outcome measure (8 of 10). 6MWT [33] and Peak W [32] were each used in one study. Of these ten studies, nine [12] [13] [14] [15] [16] [17] 30, 32, 33] reported superior improvements in exercise capacity in the IG with mTechs compared to the CG. Duscha et al. [14] reported a significant decrease in moderate-low and moderate-high PA minutes per week in the CG. In contrast, IG did not show a significant change. Frederix et al. [15] reported an increase of moderate to vigorous PA in the IG, whereas the CG showed a decrease. Frederix et al. [15] found a correlation between the number of steps per day and improvement inVO 2peak . The intervention of Fang et al. [33] led to improvements in blood pressure and smoking cessation rate. Kraal et al. [20] reported comparable results for IG and CG for health-related quality of life, but the IG showed higher satisfaction. Piotrowicz et al. [30] employed hospitalization and mortality during 14 to 26 months of follow-up as primary outcomes, and these outcomes did not differ significantly between IG and CG. Rosario et al. [31] reported a significant positive effect in the IG regarding adherence (i.e., attended exercise sessions) but no significant change in exercise capacity. Four studies [13, 16, 20, 21] analyzed the cost-effectiveness of the mTech interventions, of which two studies [20, 21] reported that home-based CR with mTechs is a cost-effective alternative to standard outpatient CR. Table 3 shows the employed technologies and PA measures and briefly summarizes technology-supported interactions with the patients. Five of the included studies used a custom smartphone app or a custom web platform [15] [16] [17] 21, 31, 33] . Four studies used commercial platforms: two studies [13, 20] used the Garmin web platform, one study [32] the Polar Flow web platform, and one study [14] the Vida mHealth platform. In two studies [12, 30] , a telerehabilitation set by Pro Plus was used for real-time telemonitored exercise training. The diverse range of employed PA monitoring devices can be classified with respect to the targeted application area: Research-targeted devices are mainly employed in research studies, such as Actigraph's devices. Custom devices are specifically developed for application in the study and are not commercially available. Off-the-shelf devices are targeted at sports and fitness tracking of the general public, such as Garmin, Polar and Fitbit devices. Research-targeted devices were used in eight studies [12, 15, 16, [19] [20] [21] 30, 33] , custom devices in two studies [17, 31] and off-the-shelf devices in four studies [13, 14, 20, 32] . The employed mTechs consisted of the following devices to measure PA: fitness watches [13, 20] , chest-worn devices [21] , smartphones [31] , activity trackers [14, 32] , belt straps with sensors [33] , motion sensors [15, 16] , mobile ECG [12, 30] , a custom sensor attached to shirt [17] , and chest straps [19] . Data of the devices was transmitted to web platforms via smartphone or PC. Off-the-shelf software (Garmin Connect) and fitness watches were used in the studies of Avila et al. [13] and Kraal et al. [20] by both the patients and the health care professionals. Health care professionals gave feedback based on the collected data, which was accessed through the Garmin Connect website. The employed fitness watches (Garmin 210 and Garmin FR70) required the upload of the data via PC. Maddison et al. [21] employed a chest-worn wearable sensor connected to a smartphone app for remote real-time monitored training. A custom smartphone app and a custom web app were provided. The system of Rosario et al. [31] consisted of a custom smartphone app, a weight scale, and a blood pressure monitor. The weight scale and the blood pressure monitor automatically transmitted data to a custom smartphone app for the patients and a web app for the health professionals. PA was computed based on the smartphone accelerometer with a custom algorithm. Vogel et al. [32] employed off-the-shelf activity trackers (Polar Loop) as well as the corresponding off-the-shelf software (Polar Flow). Data from the activity tracker was uploaded via a PC. A platform for the communication between patient and health professionals (Vida health platform) and wrist-worn activity trackers (Fitbit Charge) were employed by Duscha et al. [14] Step counts were used for personalized activity recommendations. Patients chose a health coach in the Vida health platform, who was provided with patient details, including personalized activity recommendations. The activity tracker was connected via smartphone to the platform. Fang et al. [33] employed custom software and a belt-strap for remote monitoring of training. Two studies by Frederix et al. [15, 16] employed a step counter, which was used for personalized automated feedback every week. In two studies by Piotrowicz et al. [12, 30] the patients' exercise was remotely monitored with a mobile ECG device. Additionally, a blood pressure device and weight scale were provided to the patients [30] . The study by Skobel et al. [17] used a custom smartphone app and a custom wearable sensor attached to a special shirt. Exercise prescriptions were sent to the smartphone. Snoek et al. [19] provided patients with a chest-strap and a smartphone for heart rate monitoring. Objective PA measures were diverse, including levels of intensity, active energy expenditure, moderate to vigorous activity duration, intensity or aerobic steps, steps per day, and heart rate during exercise (see Table 3 ). The computation of the PA measures was based on inertia measurements (accelerometer and/or gyroscope) [13] [14] [15] [16] [17] [19] [20] [21] [31] [32] [33] , electrocardiograms (ECG) signals [12, 17, [19] [20] [21] 30, 33] , and photoplethysmography (PPG) measurements [13, 14] . Inertia measurements were used to compute step count and step intensity, while ECG and PPG signals were used to compute heart rate. Figure 2 gives an overview of the PA measures found in literature, including common sensing hardware, basic measurements, and derived PA measures. Heart rate was measured in seven studies [12, 17, [19] [20] [21] 30, 33] , but only during exercise sessions and not continuously. Continuous PA monitoring was limited to step counts. Table 3 provides a description of the technology-supported interactions with the patients, while Table 4 presents a classification of these interactions according to BCTs. Most of the included studies did not explicitly mention the underlying theory of behavior change strategies which were incorporated in the interventions; nor did the studies code the applied BCTs by means of a common taxonomy, e.g., as proposed by Michie et al. [29] . Based on the extracted data of the description of the BCTs, we grouped the included studies according to the following common elements of BCTs: Goal setting: Was goal setting in any form included?  Self-monitoring: Was the collected data provided to the patient to allow self-monitoring?  Feedback on exercise: Was feedback on exercise given in any form during the intervention?  Physician/expert involved: Was a physician/expert involved in the application of the BCTs?  Tailored prescription: Was any part of the intervention tailored to the patient?  Real-time monitoring: Did other people than the patient monitor exercise data in realtime? Table 3 provides a description of the technology-supported interactions with the patients, while Table 4 presents a classification of these interactions according to BCTs. Most of the included studies did not explicitly mention the underlying theory of behavior change strategies which were incorporated in the interventions; nor did the studies code the applied BCTs by means of a common taxonomy, e.g., as proposed by Michie et al. [29] . Based on the extracted data of the description of the BCTs, we grouped the included studies according to the following common elements of BCTs: • All studies included in our review incorporated goal setting, self-monitoring, feedback on exercise, and integrated tailored prescriptions, such as individualized exercise prescription. All studies except two [15, 31] reported direct contact to a physician/expert via phone calls (or real-time audio coaching) [12] [13] [14] [19] [20] [21] 30, 32, 33] and/or text messages [14, 16, 17, 31, 32] . Only in one study by Rosario et al. [31] , there was no contact with physicians or health experts and automated personalized feedback was generated by an algorithm twice a week based on the monitored activity. Real-time monitoring of PA, i.e., a health professional is monitoring the patients' PA remotely, was reported in three studies [17, 21, 33] . Provision of educational material was reported in six of the included studies [14, 16, 17, 21, 30, 33] . In this scoping review on objective monitoring and promotion of PA with mTechs in CR we identified applications of mTechs in CR, study designs with three distinct group comparisons, and types of mTechs and BCTs employed in interventions. The study design with the group comparison (a) mTechs during home-based CR (IG) vs. outpatient CR without mTechs (CG) allows conclusions to be drawn whether an mTechs supported intervention could potentially replace outpatient CR. Supplying patients with mTechs that aim to improve exercise capacity during home-based CR is an effective alternative to standard outpatient CR (n = 3) [13, 20, 21] . In order to assess the effect of mTechs, the third group with home-based CR without mTechs is missing. This comparison of home-based CR with mTechs vs. home-based CR without mTechs is not found in literature. Therefore, it is not possible to assess to what extent mTechs for objective monitoring and promotion of PA add value to home-based CR. The lack of this specific comparison of mTech elements, as well as a lack of finer-grained comparisons of mTech elements, constitutes a gap in the scientific literature. Only study design (b) outpatient CR with vs. without mTechs allows to draw conclusions on the effect of mTechs as adjunct for outpatient CR; no difference is found between the IG and the CG, but few studies are available (n = 2) [31, 32] . Most of the studies employed (c) mTechs during home-based CR after outpatient CR, which may enable the cost-effective extension of CR but does not allow us to draw conclusions on the role of mTechs for objective PA monitoring. In the selected literature, the complex CR interventions are treated as one single unit. However, they consist of several elements, especially a combination of BCTs, e.g., goal setting, self-monitoring, feedback on exercise, and education. The contribution of the intervention elements to the overall effect, and success of the complex intervention remains unclear. Women are consistently underrepresented in CR [34] , although CVD is a major cause of death among women [34] . All 13 included studies lacked gender equality [12] [13] [14] [15] [16] [17] [19] [20] [21] [30] [31] [32] [33] , with only 14% female representation in total. Future research, therefore, has to address the issue of gender equality. The frequently higher dropout rates in the IG with mTechs could be attributed to the lack of technology acceptance, usability, and user-friendliness of mTechs. In the selected studies, it was reported twice that patients discontinued the interventions with mTechs because they found the usage too cumbersome [17, 35] . Similarly, Frederix et al. [15] reported that the difficulties with the employed mTech system were the main cause for dropouts. Kraal et al. [20] reported that discomfort at wearing a chest strap for heart rate monitoring was the reason for discontinuation. The use of mTechs requires digital literacy [36] and mTechs are most frequently taken up by and targeted towards younger user groups [37] . Therefore, patients' needs and preferences, i.e., in general, older people, need special consideration in the design of mTech systems for CR. User participation in the design and development of novel mTech systems for CR can help to improve technology acceptance, usability, and user-friendliness [38] . The results of the comparisons of exercise capacity between mTechs during homebased CR (IG) vs. outpatient CR (CG) suggest that mTechs might have the potential as an alternative to outpatient CR. However, there is not enough data to draw firm conclusions. Moreover, data is scarce for the comparison of exercise capacity between outpatient CR with mTechs vs. outpatient CR without mTechs. No additional improvement in exercise capacity due to mTechs was reported. It may be speculated that the patient-acceptable amount of PA was already performed in outpatient CR, and therefore, no further improvements with mTechs were achieved. Most evidence [12] [13] [14] [15] [16] [17] 30, 32, 33] was found that home-based CR with mTechs (IG) improves exercise capacity compared to no formal CR (CG). However, the extent to which mTechs contributed to this improvement cannot be assessed since no standard home-based CR was included in the study design. Piotrowicz et al. [30] reported hospitalization and mortality at follow-up appointments after 14 and 26 months. The study compared (c) outpatient CR followed by home-based CR with mTechs (IG) vs. outpatient CR without further CR. These outcome measures did not show statistically significant improvements. However, follow-up periods were short, and therefore, studies with a longer duration should assess the long-term effect of mTech-assisted CR with regard to hospitalization and mortality [13, 14, 16, 33, 39] . Off-the-shelf [13, 14, 20, 31, 32] and research-grade mobile devices [17, 21, 30] were shown to be useful for monitoring and promotion of PA in the context of CR. Nonetheless, lack of technology acceptance, usability, and user-friendliness were reported. In one study with custom hardware, the dropouts were as high as 65% [17] . Future studies might benefit from first assessing which devices are the most popular among patients to optimize adherence. Based on the available study data, no further recommendations for the choice of mTechs can be made. For BCTs, underlying behavior change theories were mostly missing and the applied BCTs were not coded using a common taxonomy, e.g., as proposed by Michie et al. [29] . Behavior change theories and frameworks should guide future design and development of complex CR interventions. Due to a lack of detail in the interventions' description, it was impossible to assess studies regarding aspects such as preparation of educational content, the usability of patients' smartphone or web applications, or content and formulation of feedback in conversations with a physician or expert. The problem of insufficient detail in the description of complex interventions is well-acknowledged in the literature, and reporting guidelines have been established [40] . For CR during and after the COVID-19 pandemic, results regarding home-based CR with mTechs are most relevant, as facilities have been temporarily closed or are not operating at full capacity. Home-based CR with off-the-shelf devices and software might be an option during this pandemic, but effectiveness needs to be confirmed by scientific studies. The field of objective PA monitoring is advancing fast, especially heart rate monitoring with optical sensors. Therefore, mTech systems described in this paper will be improved in the near future, and a similar review should be conducted in 2-3 years. In the discussion, we have identified the following main action points for the future research and implementation of CR with mTechs for monitoring and promotion of PA: 1. Aim at gender equality in CR research and implementation. Focus on technology acceptance, usability, and user experience of mTechs for CR by adopting participatory design and development methodology, especially from the so far underrepresented female perspective. Extend and enforce reporting guidelines for mTechs interventions. Research methodology for the assessment of individual elements of complex mTech CR interventions. 5. Include behavioral theories and frameworks in the development of mTech CR interventions. 6. Perform long-term studies to evaluate the sustainability of improved health-outcomes of home-based CR with mTechs. Supplying patients with mTechs to improve exercise capacity during home-based CR does not necessarily lead to the postulated success. In fact, mTechs during outpatient CR did not further improve exercise capacity compared to outpatient CR alone. It has only been shown that when home-based CR with mTechs follows outpatient CR that this strategy was superior to outpatient CR without further CR. Therefore, there is still a need for future research to evaluate the contribution of mTechs and behavior change strategy components in complex CR interventions concerning their effectiveness. In this review, we provide details of studies in which various mTechs from readily available off-the-shelf devices to custom hardware were employed. However, based on the study data, no recommendations for the choice of mTechs can be made. A lack of technology acceptance, usability, and user-friendliness of mTech systems contributed to high dropout rates. Thus, there is a need for developing highly user accepted mTech systems, especially from the underrepresented female perspective. Causes of Death Collaborators Global, Regional, and National Age-Sex Specific Mortality for 264 Causes of Death, 1980-2016: A Systematic Analysis for the Global Burden of Disease Study Forecasting the Future of Cardiovascular Disease in the United States: A Policy Statement from the American Heart Association The Effect of Physical Activity on Mortality and Cardiovascular Disease in 130 000 People from 17 High-Income, Middle-Income, and Low-Income Countries: The PURE Study ESC Guidelines on Sports Cardiology and Exercise in Patients with Cardiovascular Disease: The Task Force on Sports Cardiology and Exercise in Patients with Cardiovascular Disease of the European Society of Cardiology (ESC) Home-based versus Centre-based Cardiac Rehabilitation Lifestyle and Impact on Cardiovascular Risk Factor Control in Coronary Patients across 27 Countries: Results from the European Society of Cardiology ESC-EORP EUROASPIRE V Registry Cardiac Rehabilitation in Austria Objectively Assessed Physical Activity: Which Is Right for Public Health? Reliability and Validity of Self Report of Aerobic Activity: Family Health Project Home-Based Telemonitored Nordic Walking Training Is Well Accepted, Safe, Effective and Has High Adherence among Heart Failure Patients, Including Those with Cardiovascular Implantable Electronic Devices: A Randomised Controlled Study Home-Based Rehabilitation With Telemonitoring Guidance for Patients With Coronary Artery Disease (Short-Term Results of the TRiCH Study): Randomized Controlled Trial Effects of a 12-Week MHealth Program on Peak VO2 and Physical Activity Patterns after Completing Cardiac Rehabilitation: A Randomized Controlled Trial Increasing the Medium-Term Clinical Benefits of Hospital-Based Cardiac Rehabilitation by Physical Activity Telemonitoring in Coronary Artery Disease Patients Cardiac Telerehabilitation: A Novel Cost-Efficient Care Delivery Strategy That Can Induce Long-Term Health Benefits Internet-Based Training of Coronary Artery Patients: The Heart Cycle Trial Hybrid Comprehensive Telerehabilitation in Heart Failure Patients (TELEREH-HF): A Randomized, Multicenter, Prospective, Open-Label, Parallel Group Controlled Trial-Study Design and Description of the Intervention The Sustained Effects of Extending Cardiac Rehabilitation with a Six-Month Telemonitoring and Telecoaching Programme on Fitness, Quality of Life, Cardiovascular Risk Factors and Care Utilisation in CAD Patients: The TeleCaRe Study Clinical and Cost-Effectiveness of Home-Based Cardiac Rehabilitation Compared to Conventional, Centre-Based Cardiac Rehabilitation: Results of the FIT@Home Study Effects and Costs of Real-Time Cardiac Telerehabilitation: Randomised Controlled Non-Inferiority Trial Cardiovascular Considerations for Patients, Health Care Workers, and Health Systems During the COVID-19 Pandemic Scoping Studies: Towards a Methodological Framework Scoping Studies: Advancing the Methodology PRISMA-ScR): Checklist and Explanation The PRISMA Statement for Reporting Systematic Reviews and Meta-Analyses of Studies That Evaluate Health Care Interventions: Explanation and Elaboration Comparisons of Leisure-Time Physical Activity and Cardiorespiratory Fitness as Predictors of All-Cause Mortality in Men and Women Exercise Capacity and Mortality among Men Referred for Exercise Testing The Behavior Change Technique Taxonomy (v1) of 93 Hierarchically Clustered Techniques: Building an International Consensus for the Reporting of Behavior Change Interventions Effects of a 9-Week Hybrid Comprehensive Telerehabilitation Program on Long-Term Outcomes in Patients With Heart Failure: The Telerehabilitation in Heart Failure Patients (TELEREH-HF) Randomized Clinical Trial Evaluation of an MHealth-Based Adjunct to Outpatient Cardiac Rehabilitation Digitally Enhanced Recovery: Investigating the Use of Digital Self-Tracking for Monitoring Leisure Time Physical Activity of Cardiovascular Disease (CVD) Patients Undergoing Cardiac Rehabilitation Innovative Application of a Home-Based and Remote Sensing Cardiac Rehabilitation Protocol in Chinese Patients After Percutaneous Coronary Intervention Sex Bias in Referral of Women to Outpatient Cardiac Rehabilitation? A Meta-Analysis An M-Health System for Education and Motivation in Cardiac Rehabilitation: The Experience of HeartCycle Guided Exercise New Technologies, New Disparities: The Intersection of Electronic Health and Digital Health Literacy Using Smartphones and Health Apps to Change and Manage Health Behaviors: A Population-Based Survey Roadmap for Innovation-ACC Health Policy Statement on Healthcare Transformation in the Era of Digital Health, Big Data, and Precision Health Features, Outcomes, and Challenges in Mobile Health Interventions for Patients Living with Chronic Diseases: A Review of Systematic Reviews Better Reporting of Interventions: Template for Intervention Description and Replication (TIDieR) Checklist and Guide We would like to thank Eva-Maria Strumegger for her contribution in the graphic design of Figure 2 . The authors declared no potential conflicts of interest with respect to the research, authorship, and/or publication of this article.