key: cord-0794632-2p9rcasv authors: Fuchs, Marc; Radulescu, Clara; Tang, Miao; Mahesh, Arun; Lavin, Deborah; Umbreen, Syed; McKenna, James; Smyth, Mark; McColgan, Eilís; Molnar, Zoltan; Baxter, Chris; Skvortsov, Timofey; Singh, Aditi; Rogan, Fiona; Miskelly, Julia; Bridgett, Stephen; Fairley, Derek; Simpson, David A. title: Mini-XT, a miniaturized tagmentation-based protocol for efficient sequencing of SARS-CoV-2 date: 2022-03-03 journal: J Transl Med DOI: 10.1186/s12967-022-03307-9 sha: 95db2f441b13418e467d01cb5f6143d7738711ab doc_id: 794632 cord_uid: 2p9rcasv BACKGROUND: The COVID-19 pandemic has highlighted the importance of whole genome sequencing (WGS) of SARS-CoV-2 to inform public health policy. By enabling definition of lineages it facilitates tracking of the global spread of the virus. The evolution of new variants can be monitored and knowledge of specific mutations provides insights into the mechanisms through which the virus increases transmissibility or evades immunity. To date almost 1 million SARS-CoV-2 genomes have been sequenced by members of the COVID-19 Genomics UK (COG-UK) Consortium. To achieve similar feats in a more cost-effective and sustainable manner in future, improved high throughput virus sequencing protocols are required. We have therefore developed a miniaturized library preparation protocol with drastically reduced consumable use and costs. RESULTS: We present the ‘Mini-XT’ miniaturized tagmentation-based library preparation protocol available on protocols.io (10.17504/protocols.io.bvntn5en). SARS-CoV-2 RNA was amplified using the ARTIC nCov-2019 multiplex RT-PCR protocol and purified using a conventional liquid handling system. Acoustic liquid transfer (Echo 525) was employed to reduce reaction volumes and the number of tips required for a Nextera XT library preparation. Sequencing was performed on an Illumina MiSeq. The final version of Mini-XT has been used to sequence 4384 SARS-CoV-2 samples from N. Ireland with a COG-UK QC pass rate of 97.4%. Sequencing quality was comparable and lineage calling consistent for replicate samples processed with full volume Nextera DNA Flex (333 samples) or using nanopore technology (20 samples). SNP calling between Mini-XT and these technologies was consistent and sequences from replicate samples paired together in maximum likelihood phylogenetic trees. CONCLUSIONS: The Mini-XT protocol maintains sequence quality while reducing library preparation reagent volumes eightfold and halving overall tip usage from sample to sequence to provide concomitant cost savings relative to standard protocols. This will enable more efficient high-throughput sequencing of SARS-CoV-2 isolates and future pathogen WGS. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12967-022-03307-9. Genomics UK Consortium) [1, 2] . Many approaches have been developed to enrich SARS-CoV-2 for WGS, including target capture, and virus-specific reverse transcription [3] [4] [5] . While these have some advantages, random primed reverse transcription followed by multiplex tiled PCR has been most widely adopted. The ARTIC protocol [6] has been used in many studies [7, 8] and employs two pools of primers, which are being continually improved [9] , to amplify ~ 400 bp tiled amplicons. Particularly in the early stages of the pandemic nanopore sequencing was used to provide rapid turnaround for single or small batches of samples. Increasing prevalence and recognition of the value of sequencing all positive cases has driven demand for higher throughput methods. Although nanopore protocols now enable multiplexing of 96 samples, sequencing platforms with greater output, such as Illumina, are more suitable. Both the cost and availability of reagents are critical determinants of the number of samples that can be processed. The disruption caused by the pandemic to manufacturing and the logistics of reagent delivery, in combination with a significantly increased global demand for viral RNA extraction and sequencing, resulted in delivery delays and temporary shortages of laboratory consumables in many countries, impacting not only COVID-19 testing, but other clinical and fundamental microbiology research [10] . To maximise throughput from a given stock of reagents, protocols have been modified to reduce volumes (eg ARTIC V1 to V3) or been specifically designed to minimize the reagents required, such as CoronaHIT [11] . Automation is an essential part of any high throughput protocol, but unfortunately processing of multiple plates requires many expensive plastic pipette tips. This also raises logistical challenges due to COVID-related delays and has longer term sustainability issues. Acoustic liquid handling enables the transfer of low volumes in the nanolitre range without the use of physical tips [12] . We and others have previously applied this technology to the preparation of, for example, synthetic DNA [13] , RNA-Seq [14] [15] [16] and plasmid libraries. Here we present a 'Mini-XT' protocol for sequencing of SARS-CoV-2 using ARTIC tiled amplicons, Nextera XT-based library preparation miniaturized using an Echo 525 liquid handling system (Beckmann) and sequencing on an Illumina MiSeq. Details are available on protocols.io (https:// doi. org/ 10. 17504/ proto cols. io. bvntn 5en). This enables a tenfold reduction in reagents relative to the standard Nextera XT protocol and use of significantly fewer disposable plastic tips. We have used the Mini-XT protocol to generate over 4000 SARS-CoV-2 genome sequences, with quality comparable to those prepared using full volume DNA Flex library preparation or on the nanopore platform. This study analysed primarily Northern Irish 'Pillar 2' (swab testing for the wider population) SARS-CoV-2 samples from Randox Laboratories, with a smaller number of 'Pillar 1' (NHS swab testing for those with a clinical need, and health and care workers) samples from the Belfast Trust used in comparisons between sequencing protocols. To facilitate high throughput whole genome sequencing of these samples and to reduce consumable use, a miniaturised version of the Nextera XT (Illumina) library preparation protocol called 'Mini-XT' was developed. A graphical overview is provided in Fig. 1 , with the full protocol available at https:// doi. org/ 10. 17504/ proto cols. io. bvntn 5en. A list of reagents is provided in Additional file 1. We report here a total of 4384 samples processed using the Mini-XT protocol of which 4271 (97.4%) passed COG-UK QC. This is comparable with the results of the study by Baker et al., in which the maximum pass rate of 97.6% was reported for higher viral load samples with a known Ct of 32 or lower processed using CoronaHiT-Illumina [11] . The sequencing metrics for the runs organised in date order are shown in Fig. 2 . An extended figure of all runs completed since January 2021 (Additional file 2: Fig. S1 ) demonstrates the improved consistency as the final protocol was established. One recent run 210,622 failed to reach acceptable QC and was excluded from further analysis. As expected, the percentage of samples passing QC closely mirrored the mean percent per sample of bases covered. In addition to read depth the distribution of reads is critical and probably explains why the correlation between the mean number of aligned reads per sample and percentage of samples passing QC was less significant. As expected, the percent of bases covered by the consensus sequence reduces slightly as the Ct value increases, from over 99% in the most concentrated samples (Ct < 20) to 97% in those samples with the highest Ct's tested (28 ≤ Ct < 30) (Additional file 2: Fig. S2 ). To test whether the approximately tenfold reduction in reagents used in the Mini-XT protocol compromises performance relative to standard full volume DNA-Flex protocols, four 96 well plates of samples were processed in parallel using both approaches. The sequencing metrics, including percent coverage ( Fig. 3 ; Additional file 2: Fig. S3 ) were broadly comparable. For 202 samples the lineage calls from both protocols were identical, for 5 the same but with descendant sublineages missing from one of the calls and for 4 there were discrepancies in sub-lineages between protocols. In these 4 cases most of the characteristic variants are common between the discrepant sublineages (Additional file 2: Fig. S4 ; [17] ) and the differing calls presumably reflect differing sequence quality at the discriminating sites. In a phylogenetic tree created with the consensus sequences generated using Mini-XT and DNA-Flex protocols, the same samples sequenced by different technologies clustered together (Fig. 3) , reflecting the consistency of SNP calling between methods. Nanopore sequencing is widely used throughout the COG-UK consortium [2] and we use this approach for samples requiring a rapid turnaround. To further validate the Mini-XT protocol we compared the results of 20 samples that had also been sequenced using the nanopore platform. The sequencing metrics were broadly comparable (Fig. 4A ). The lineage calls were identical for the same samples processed using each technology and the sample pairs clustered together when plotted on a phylogenetic tree (Fig. 4B) . The use of acoustic liquid transfer enables a significant reduction in the use of consumables, in particular plastic tips. This equates to an approximately 90% reduction in tips required during library preparation and a reduction from 23 to 12 tips per sample for processing from RNA sample to completed library. New England Biolabs (NEB) have released re-balanced ARTIC primer pools aimed at improving uniformity of SARS-CoV-2 genome coverage and an associated library preparation kit. For a small number of samples tested, the coverage obtained with the ARTIC v3 primers used throughout the rest of this study and the NEB pools was comparable (Additional file 2: Fig. S5 ). The same amplicon pools processed with Mini-XT or the NEB library preparation protocol produced similar results. A new version of the ARTIC primers (v4) has recently been released. In a comparison between 20 samples amplified with v3 or v4 primers the latest version performed better, with a reduced percent of N bases (0.54% vs. 2.17%), increased percent of covered bases (99.4% vs. 97.8%) and increased longest no N run (28,919% vs. 20,222%) (Fig. 5 ). WGS has become a critical part of the international response to the COVID-19 pandemic [1] and will be key in any similar future situations. Indeed, WGS is now an established tool for monitoring many infectious diseases in both the USA [18] and Europe [19] . This increasing demand necessitates the development of more costeffective high throughput library preparation methods. The ability of the Echo 525 liquid handler to dispense low volumes in a 384 plate format has already been exploited for high throughput low-cost RT-qPCR SARS-CoV-2 surveillance testing [20] . Although various high throughput protocols for sequencing of SARS-CoV-2 have been reported [11, 21, 22] , the use of acoustic liquid transfer enabled a greater reduction in volume in the Mini-XT protocol than many alternatives. The ability of the Echo system to dispense variable volumes also facilitated efficient normalization of amplicon pool concentrations. As with other robotic platforms, automation of sample preparation minimises human error and improves consistency. Similar protocols employing acoustic liquid transfer to reduce reagent volumes for generating libraries for RNA-Seq and synthetic biology applications have been reported previously by us [14] and others [13, 15, 16] . However, Mini-XT is the first such protocol to be applied specifically to whole-genome sequencing of SARS-CoV-2. The confirmation that sequence quality is comparable to that achieved with conventional Illumina or Oxford Nanopore library preparation protocols provides confidence in use of this approach for virus surveillance and research to understand viral transmission and evolution. The thousands of samples processed and reported here demonstrate the robustness of the protocol. While Artic v3 primers were used for amplification of SARS-CoV-2 cDNA throughout the study, the initial findings reported for the v4 primer set suggest that it will improve the quality of sequences generated. The Mini-XT protocol can be used to prepare libraries from any DNA sample, and we anticipate that it will be of use for wider pathogen WGS applications because it can simultaneously decrease costs and dramatically increase sample throughput. Increased use of WGS for public health surveillance and in clinical microbiology are current objectives in Europe [19] that Mini-XT sequencing could facilitate. This approach may also be valuable in the emerging field of clinical metagenomics. Direct metagenome sequencing has the potential to transform diagnostic clinical virology in particular [23, 24] . Wider use of high-throughput sequencing for diagnosis is often limited by cost and capacity constraints, so there is great scope to apply novel methods such as Mini-XT sequencing in this area. One of the most effective ways for labs to become more sustainable is to reduce single use plasticware [25] . The Mini-XT protocol requires a remarkable ~ 4600 fewer tips per 384 samples processed than equivalent conventional manual or robotic preparation. Not only does this reduce waste, but also makes the protocol more resilient to consumable shortages, such as experienced during the COVID-19 pandemic. Although the Mini-XT protocol is optimized for high-throughput use, which maximizes reagent and We have demonstrated that sequence quality can be maintained after applying acoustic liquid transfer to dramatically reduce reagent volumes during library preparation. The resulting Mini-XT protocol provides an effective, robust, low cost, high-throughput library preparation approach for WGS of SARS-CoV-2. The value of large-scale sequencing of SARS-CoV-2 has been demonstrated during the COVID-19 pandemic and this protocol will facilitate the ongoing provision of whole-genome sequences. MiniXT Sample20 Nanopore Sample20 MiniXT Sample18 Nanopore Sample18 MiniXT Sample15 Nanopore Sample15 MiniXT Sample12 Nanopore Sample12 MiniXT Sample9 Nanopore Sample9 MiniXT Sample8 Nanopore Sample8 MiniXT Sample4 Nanopore Sample4 MiniXT Sample3 Nanopore Sample3 MiniXT Sample2 Nanopore Sample2 MiniXT Sample1 Nanopore Sample1 Reference cols. io/ view/ ncov-2019-seque ncing-proto col-v3locost-bh42j 8ye) and its modified version adapted for use with Illumina sequencers (https:// doi. org/ 10. 17504/ proto cols. io. bnn7m dhn) [26] . cDNA setup was performed in a pre-PCR environment and bench surfaces and pipettes were disinfected before starting work. SARS-CoV-2 viral nucleic acid extracts and two non-template controls containing nuclease-free water per 96-well plate (NTCs), were reverse transcribed with LunaScript RT SuperMix Kit (NEB), using 5 µl of the RNA sample in a total reaction of 10 µl. The reactions were incubated for 2 min at 25 °C, followed by 20 min at 55 °C and 1 min at 95 °C before cooling to 4 °C. The cDNA samples were amplified by tiled PCR using separate primer pools derived from premixed ARTIC nCoV-2019 V3 panel (100 µM, IDT) diluted 1:10 in molecular grade water, to achieve 10 µM primer stocks. Two PCR reactions per sample plate, for primer Pools A and B, were performed in a total volume of 25 µl A pair of PCR A and PCR B plates were centrifuged at 280×g and 10 µl from each well of plate A and B combined in a fresh fully skirted PCR plate. Automated bead cleaning was performed using a Biomek NXp robot (Beckman Coulter. CA) with an 8 channel head using 1.5 × KAPA Pure beads (Roche) to sample ratio. Samples were eluted in 60 µl 10 mM Tris pH 8.0 and quantified using an Invitrogen Quant-iT dsDNA broad range assay kit (Q33130) with a PHERAstar FS multimode microplate reader (BMG Labtech). The quantified RT-PCR products (A + B amplicons) were normalised to 0. (Illumina) in combination with the Nextera XT Index Kit v2 Set A and Set D. The manufacturer recommended volumes were scaled down tenfold and the reactions prepared using the Echo Liquid Handler. For the tagmentation reaction, 1000 nl Tagment DNA Buffer was transferred from a 6-reservoir Echo source plate (001-11101) into a 384-well PCR plate (Library preparation plate), followed by 500 nl of amplicons from the normalisation plate and 500 nl of Amplicon Tagment Mix from a 384PP 2.0 plate. After spindown, the plates were incubated at 55 °C for 5 min on a Tetrad DNA Engine 2 thermal cycler (Bio-Rad) and then placed on ice. Five hundred nl of Neutralize Tagment Buffer was added to the Library Preparation plate from a 6-reservoir source plate to stop the tagmentation reaction, followed by a 5 min incubation at room temperature. The library amplification reaction was again prepared with the Echo. The Nextera XT Indexes were presented on a 384PP 2.0 plate and transferred to the Library preparation plate so that each well received one of the 384 possible unique index combinations. After that, 1500 nl of Nextera PCR Master Mix was transferred from a 6-reservoir plate into the Library preparation plate. After another spin-down, the libraries were amplified on a Tetrad DNA Engine 2 in 12 PCR cycles as outlined in the Illumina Protocol for Nextera XT Library preparations. Up to 384 amplified Libraries were pooled without normalisation and purified in two consecutive 1.6× bead cleanups with KAPA Pure beads. Two wash steps per cleanup were performed with 80% ethanol, and the pool was eluted in 10 mM Tris at pH 8.0, quantified with High sensitivity Qubit dsDNA assay (Thermo Fisher Scientific, MA) and analysed with a Tapestation D1000 assay (Agilent, CA) to determine the average fragment size. The molarity was calculated based on the Qubit concentration and the D1000 size, applying an average molecular weight of 660 g/mol per 1 bp of dsDNA: The Library pool was diluted to 4 nM with 10 mM Tris pH 8.0, denatured with 0.2 N NaOH solution and diluted to 20 pM with Hyb Buffer following Illumina instructions for the Miseq. The 20 pM pool was further diluted to 9 pM and spiked with 1% PhiX at 12.5 pM before being loaded onto a sequencing cartridge. 150 bp paired-end sequencing was performed on a MiSeq system using the 300-cycle v2 MiSeq Reagent Kit. FASTQ generation was performed on-board with the Local Run Manager v3.0, secondary analysis was performed off-board as described below. The Nanopore library preparation protocol was adapted from nCoV-2019 sequencing protocols v2 (https:// doi. org/ 10. 17504/ proto cols. io. bdp7i 5rn) and v3 (https:// proto cols. io/ view/ ncov-2019-seque ncing-proto col-v3locost-bh42j 8ye) and the amended protocol is available on protocols.io: https:// www. proto cols. io/ priva te/ 8BFC7 458DD 268B8 46ADA 0B5CA 5A71C 57. All reagents are detailed in (Additional file 1). NEBNext Ultra II End Repair/dA-Tailing Module (E7546, New England Biolabs, MA) was used for end preparation of purified amplicon, for which 1. nuclease-free water added to a volume of 10 μl per reaction. The mixture was incubated at room temperature for 15 min and 65 °C for 15 min, followed by incubation on ice for 1 min. For sample multiplexing, ligation of barcodes was then performed using NEBNext ® Ultra ™ II Ligation Module (E7595, New England Biolabs, Ipswich, MA, United States) and Native Barcoding Expansion kits (EXP-NBD104/EXP-NBD114/EXP-NBD196, Oxford Nanopore Technologies, Oxford, UK). The end preparation product from the previous step (0.75 μl) was input into the ligation reaction by adding 5 μl Ultra II Ligation Master Mix, 0.15 μl Ligation Enhancer, 1.25 μl Native barcode, and 2.85 μl Nuclease-free water. The mixture was incubated at room temperature for 20 min and 65 °C for 10 min, followed by incubation on ice for 1 min. Samples were pooled together and purified using KAPA Pure Beads with 0.4× beads-to-sample ratio. The barcoded amplicon pool and beads were incubated at room temperature for 5 min, and the pellet was washed twice in 250 μl Short Fragment Buffer (EXP-SFB001, Oxford Nanopore Technologies, Oxford, UK), followed by one wash in 200 μl 70% ethanol. The barcoded amplicon pool was eluted in 30 μl Elution Buffer (LSK-109, Oxford Nanopore Technologies, Oxford, UK) and quantified using Qubit ™ dsDNA HS Assay Kit. The ligation of adaptors was performed using NEB-Next ® Quick Ligation Module (E6056, New England Biolabs, Ipswich, MA, United States) and Adapter Mix (AMII) from Native Barcoding Expansion kits. The ligation reaction was performed by adding 10 μl Quick Ligation Reaction Buffer (5×), 5 μl Quick T4 DNA Ligase and 5 μl Adapter Mix (AMII) to the 30 μl barcoded amplicon pool from the previous step and incubating the mixture at room temperature for 20 min. The adaptor-ligated amplicon pool and 50 μl beads were incubated at room temperature for 5 min, the pellet washed twice in 250 μl Short Fragment Buffer and the purified library eluted in 15 μl Elution Buffer and quantified using Qubit ™ dsDNA HS Assay Kit. MinION sequencing was performed on R9.4 flow cells (FLO-MIN106D, Oxford Nanopore Technologies, Oxford, UK) following manufacturer's guidelines. Min-ION sequencing was controlled using MinKNOW ™ software. Up to 15 ng of purified library was input into the loading library by adding 37.5 μl Sequencing buffer and 25.5 μl Loading beads (LSK-109, Oxford Nanopore Technologies, Oxford, UK). Elution buffer was added to a volume of 75 μl loading library. The run was monitored with the assistance of ARTIC-nCoV-RAMPART-v1.0.0 (https:// artic. netwo rk/ ncov-2019/ ncov2 019-using-rampa rt. html). For each Illumina sequencing run, the base-calling and demultiplexing of reads by sample-id, was routinely performed by the "MiSeq Reporter" software [27] . The resulting data was then transferred from the Illumina MiSeq computer to the Queen's University Kelvin2 HPC compute cluster for analysis. (Optionally, if the samplesheet required modification, the Illumina "bcl2fastq" [28] or "BCL Convert" [29] pipeline was used to base-call and demultiplex the data). The "connor-lab/ncov2019-artic-nf " nextflow-based open-source pipeline [30] , as used by the COG-UK consortium, was then used with its "illumina" and "profile conda" options, and otherwise default options. Internally, this pipeline uses: "TrimGalore" [31] to trim the adapter sequence from the paired reads; then "bwamem" [32] with default options to align the trimmed reads to the Wuhan-Hu-1 reference genome (accession id: MN908947.3); "samtools" to sort the aligned reads in the bam files, then "iVar" [33] to trim the ARTIC amplicons and generate a consensus fasta sequence for each sample. To determine which resulting samples are accepted, a python QC script is used to accept those consensus sequences that have either over 50% of reference bases covered by at least 10 reads, or have a stretch of more than 10 Kbp of sequence without N's (where N's are defined as bases with less than 10 reads). To analyse Nanopore data, the ncov2019-artic nextflow pipeline [30] was used to automate the ARTIC network nCoV-2019 novel coronavirus bioinformatics protocol [34] . Firstly, the Guppy program (available from https:// commu nity. nanop orete ch. com/ downl oads) was used for basecalling and demultiplexing of reads, using the "require_barcodes_both_ends" options, and arrangement files nb12 and nb24: guppy_barcoder --require_bar-codes_both_ends -i run_name -s out-put_directory --arrangements_files "barcode_arrs_nb12.cfg barcode_arrs_ nb24.cfg" Then the ncov2019-artic pipeline was run with the '--nanopolish' option. The pipeline's nanopore configuration file (https:// github. com/ connor-lab/ ncov2 019-artic-nf/ blob/ master/ conf/ nanop ore. config) specifies the parameters used for the analysis. As the ARTIC protocol can generate chimeric reads, the artic "guppyplex" program is used to accept reads with length of 400 to 700 bases, then samples with fewer than 10 reads are excluded. Barcodes having fewer than 100 reads are ignored. The minimap2 [35] read aligner is used. To call consequences of a variant on the encoded amino acid, the typing frequency threshold was 0.75 and minimum coverage depth 20. "Pangolin" [36] and "PangoLEARN" [37] were used to assign each qc-passed sample's genome consensus sequence to the most likely Pango lineage [38] . The mini-map2 pair-wise aligner and the "type_variants" [39] script were used to call specific variants of interest/concern, and the "SnipIt" [40] package was used to plot an image of the variants in each sample compared to the Wuhan reference. Data was collated and summarised using bash and python scripts. Phylogenetic analysis was performed using the 'Nextstrain' collection of tools (nextstrain.cli 3.0.3) [41] to analyse our consensus fasta sequences. The linux-based command line module, specifically the Augur module, was used to perform alignment and infer trees. The online version contains supplementary material available at https:// doi. org/ 10. 1186/ s12967-022-03307-9. Additional file 1. Reagents required for the Mini-XT protocol. Additional file 2: Figure S1 . Mini-XT sequencing metrics for all individual Mini-XT runs indicated by date (YYMMDD). Figure S2 . RT-qPCR Ct values of the SARS-CoV-2 positive RNA samples sequenced using Mini-XT vs. percent of bases covered. A Relationship between Ct value (Orf1ab target gene) and the percent of bases covered in SARS-CoV-2 genome sequences for 2000 samples processed with the Mini-XT protocol. B Average percent covered bases (± SD) for samples with increasing Ct ranges (excluding samples with one or both amplicon pools failing, ie percent covered bases < 70). Figure S3 . Comparison of individual 96 well plates of samples prepared using the DNA Flex library kit with the same samples prepared with the Mini-XT protocol. The concentrations of the amplicon pools are indicated in ng/µl and broadly correlate with the percentage coverage achieved. The insets indicate the total number of aligned reads for each set of samples. Figure S4 . Characteristic variants of sublineages called differentially between sequencing protocols. SNP-IT plots indicate that all the SNPs called from Mini-XT and Flex sequences are either shared or not called in one sequence. The comparison illustrates that most characteristic variants of the discrepant lineages are shared and only vary at several positions. Figure S5 . Comparison of Arctic v3 and NEB primer pools. Samples are named according to the amplification and then library preparation method and ordered according to percentage coverage achieved with Articv3 primers and mini-XT library preparation (Artic_MiniXT). The COVID-19 Genomics UK (COG-UK) consortium. An integrated national scale SARS-CoV-2 genomic surveillance network Rapid cost-effective viral genome sequencing by V-seq. Cold Spring Harb Lab Multiple approaches for massively parallel sequencing of SARS-CoV-2 genomes directly from clinical samples Evaluation of NGS-based approaches for SARS-CoV-2 whole genome characterisation nCoV-2019 sequencing protocol v3 (LoCost) A rapid, low cost, and highly sensitive SARS-CoV-2 diagnostic based on whole genome sequencing. Cold Spring Harb Lab High throughput nanopore sequencing of SARS-CoV-2 viral genomes from patient samples. Cold Spring Harb Lab Improvements to the ARTIC multiplex PCR method for SARS-CoV-2 genome sequencing using nanopore Supply shortages impacting COVID-19 and non-COVID testing. 2021. ASM.org Coro-naHiT: high-throughput sequencing of SARS-CoV-2 genomes Technologies that enable accurate and precise nano-to milliliterscale liquid dispensing of aqueous reagents using acoustic droplet ejection Low-cost, high-throughput sequencing of DNA assemblies using a highly multiplexed nextera process Single-cell transcriptomic profiling provides insights into retinal endothelial barrier properties High-throughput minitaturized RNA-Seq library preparation Miniaturization and optimization of 384-well compatible RNA sequencing library preparation Next-generation sequencing of infectious pathogens ECDC strategic framework for the integration of molecular and genomic typing into European surveillance and multi-country outbreak investigations-2019-2021. ECDC: Stockholm Automated, high-throughput and low-cost RT-qPCR methods for SARS-CoV-2 surveillance testing using the Echo 525 Liquid Handler High throughput detection and genetic epidemiology of SARS-CoV-2 using COVIDSeq next-generation sequencing A rapid, cost-effective tailed amplicon method for sequencing SARS-CoV-2 Improved diagnosis of viral encephalitis in adult and pediatric hematological patients using viral metagenomics Recommendations for the introduction of metagenomic high-throughput sequencing in clinical virology, part I: wet lab procedure Labs should cut plastic waste too nCoV-2019 sequencing protocol for Illumina V Nextflow pipeline for running the ARTIC network's field bioinformatics tools Aligning sequence reads, clone sequences and assembly contigs with BWA-MEM An amplicon-based sequencing framework for accurately measuring intrahost virus diversity using PrimalSeq and iVar NCoV-2019 novel coronavirus bioinformatics protocol Minimap2: pairwise alignment for nucleotide sequences Phylogenetic Assignment of Named Global Outbreak LINeages) package PangoLEARN-trained models used by pangolin A dynamic nomenclature proposal for SARS-CoV-2 lineages to assist genomic epidemiology MAFFT: a novel method for rapid multiple sequence alignment based on fast Fourier transform Nextstrain: real-time tracking of pathogen evolution Publisher's Note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations Thanks to the Queen's University Belfast Genomics CTU (https:// www. qub. ac. uk/ sites/ core-techn ology-units/ Genom ics/) for access to facilities and advice. Thanks to staff of the Belfast Health & Social Care Trust Regional Virus Lab (RVL) and Randox Laboratories for provision of positive samples for sequencing. Thanks to Vaughan Purnell for managing the Kelvin2 HPC used for data analysis and configuring storage, cluster job-queues, installing software and giving helpful advice. MF designed the mini-XT protocol and together with CR, MT, AM, DL, SU, CB, FR, JMcK, MS, EM, and ZM processed samples to generate sequence data. JM, DF and DAS oversaw data acquisition. AM and DL set up the protocol on protocols.io. AS, SB and TS analysed sequence data. DF, CR, MT, AR, DL, FR, AS, SB and TS assisted with manuscript preparation. DAS conceived the study, interpreted the data and prepared the manuscript. All authors read and approved the final manuscript. The sequencing costs were funded by the COVID-19 Genomics UK (COG-UK) Consortium which is supported by funding from the Medical Research Council (MRC) part of UK Research & Innovation (UKRI), the National Institute of Health Research (NIHR) and Genome Research Limited, operating as the Wellcome Sanger Institute. Additional funding was provided by Public Health England (PHE). The datasets generated during the current study are available via MRC CLIMB, [http:// www. climb. ac. uk/] (additional control datasets analysed during the current study are available from the corresponding author on reasonable request). The COVID-19 Genomics UK Consortium has been given approval by Public Health England's Research Ethics and Governance Group (PHE R&D Ref: NR0195). Written informed consent was not required as only excess diagnostic samples were used and no patient identifiable information was collected or presented. The research conformed to the principles of the Helsinki Declaration. Not applicable. The authors declare that they have no competing interests.