key: cord-0810096-dzah4ftj authors: Emperador, Francis; Bennett, Sean R; Gonzalez, Julia; Saati, Ahmed; Alsaywid, Basim S; Fernandez, Jose A title: Extravascular Lung Water and Effect on Oxygenation Assessed by Lung Ultrasound in Adult Cardiac Surgery date: 2020-08-23 journal: Cureus DOI: 10.7759/cureus.9953 sha: 1fb8b2543298f4bd6aff6a7abea77937261a511e doc_id: 810096 cord_uid: dzah4ftj Introduction The extravascular lung water content is determined by the use of lung ultrasound (LUS) which is represented as B-lines. The aim of this study was to investigate whether the LUS measurement of extravascular lung water was correlated to changes in oxygenation. Methods This prospective cohort study was comprised of 73 patients with an average age of 56 (range: 18 to 87 years) who underwent elective cardiac surgery using cardiopulmonary bypass. The LUS score was performed preoperatively, time zero (T0), at one hour (T1), and at 24 hours (T2) post-surgery. Additionally, arterial oxygen partial pressure and fraction of inspired oxygen (PaO(2)/FiO(2)) ratio were measured at each time and the time-to-extubation. Results A negative correlation was found between the LUS score and PaO(2)/FiO(2) at T1 (p < 0.004). Extubation time and changes in the lung ultrasound score at T0 - T2 were positively correlated (p < 0.03). Plus, there was a positive correlation between fluid balance and lung ultrasound score at T2 (p < 0.03). Conclusion We found three significant correlations that support the use of LUS in cardiac surgery: 1) the more B-lines, the lower the oxygenation; 2) the more B-lines, the longer the period of ventilation; 3) the more B-lines, the more positive the fluid balance. LUS is a non-invasive bedside investigation that can be used to judge extravascular lung water, providing useful information in the management of patient oxygenation, fluid balance, and extubation. Lung ultrasound (LUS) has received much attention in the last decade due to its use in many areas: critical care, emergency medicine, trauma surgery, and more recently, paediatric and adult cardiac surgery, in which it offers an important tool for monitoring and diagnostic purposes [1] [2] . LUS is a bedside tool that is free of radiation, reproducible, and cost-effective [1] . LUS can detect excess extravascular lung water (EVLW) and is a predictor of pulmonary oedema. EVLW is the amount of fluid that accumulates in the interstitial and alveolar spaces. It is represented by B-lines, which are artifacts that appear on LUS [2] . Most adult patients having cardiac surgery using cardiopulmonary bypass (CPB) have a positive fluid balance postoperatively. Early extubation (less than four hours) has become normal for routine cardiac surgery. This requires attention to body temperature, analgesia, and bleeding but also a fluid balance that avoids pulmonary oedema or hypoxia as positive pressure ventilation is discontinued. Pulmonary complications relating to excess lung water include poor oxygenation and reduced compliance resulting in prolonged ventilation. Knowing the preoperative state of the EVLW for the patient and optimizing the perioperative care can be crucial for improving the outcomes after cardiac surgery. However, there are currently no guidelines for the use of LUS post-cardiac surgery and few data related to this topic. The aim of this study was to assess EVLW before and after cardiac surgery by scoring B-lines using LUS. The primary outcomes were to assess the relationship between B-lines and the effect on oxygenation and time of extubation (Extub T). Secondary outcomes were the influence of CPB time, aortic cross-clamp (ACC) time, and fluid balance at one hour (T1) and 24 hours postoperatively (T2) on oxygenation. Also recorded was the presence of pleural effusion (PE) and consolidation. The study was designed as a prospective cohort study in elective cardiac surgery using CPB. The study was performed at the King Abdulaziz Medical City in the National Guard, King Faisal Cardiac Center between March 2018 and March 2019. The protocol was approved by the Institutional Review Board at the King Abdullah International Medical Research Center, #RYD-18-417780-17652. Written consent was obtained from all patients prior to surgery. The inclusion criteria were patients older than 18 years who were scheduled for elective cardiac surgery using CPB. Patients with pulmonary fibrosis and chronic obstructive lung disease were included. The exclusion criteria were emergency procedures. The patient characteristics and baseline clinical data were collected for every patient, including age, weight, height, diagnosis, previous pulmonary pathology, logistic European System for Cardiac Operative Risk Evaluation (euroSCORE) [3] , and type of surgery ( Table 1) . The ventilation strategy was: Pre-bypass: volume control respiratory rate (RR) 10 -12 per minute (keeping CO 2 between 35 -45 mmHg), tidal volume: 4 -6 ml/kg, positive end expiratory pressure (PEEP) 0, fraction of inspired oxygen (FiO 2 ) 0.5, and inspiratory:expiratory (I:E) 1:2. Post-bypass: volume control RR 10 -12 (keeping CO 2 between 35 -45 mmHg), tidal volume: 4 -6 ml/kg, PEEP 0, FiO 2 0.5, and I:E 1:2. ICU: volume: 4 -6 ml/kg and PEEP 5+ according to FiO 2 . O 2 started at 50% until the first arterial blood gas sample and adjusted. Weaning protocol: Patients were not routinely sedated. Patients received analgesia by fentanyl infusion and paracetamol. When the patient started to respond, they were put onto synchronized intermittent mandatory ventilation (SIMV) and then pressure support prior to extubation. FiO 2 : < 0.4, PEEP 5, pressure support: 10. A chest x-ray was obtained before extubation. The LUS examination was performed using a Philips CX50 and phased array probe 2 -4 MHZ with a lung ultrasound preset (Koninklijke Philips N.V., Amsterdam, Netherlands). The LUS score was recorded pre-surgery (awake) (T0), one-hour post-surgery (T1), and 24 hours post-surgery (T2), as well as oxygenation ( Figure 1 ). The ultrasound was performed by an anaesthetist who had experience in LUS. Patients were scanned in the supine position according to the method described by Volpicelli et al. [5] . We included a posterior scan area in addition so that a better appraisal of effusion and consolidation could be made. This may have increased the LUS score, but the conditions were the same for all patients. Thus, we had 10 anatomical sites that were assessed by LUS ( Figure 2 ). performed. Ten areas were examined (1 -10). The lung ultrasound score was the total of the scores for the 10 areas. Figure 2 shows the corresponding numbers for the right and left sides of the thorax. The LUS score was calculated according to the number of B-lines and the presence of a pleural effusion and/or consolidation which was recorded as 'yes' or 'no' ( At the time of the protocol, there were no previous studies investigating LUS for the assessment of EVLW in adult cardiac surgery. Our sample size was calculated for our primary outcome which was the assessment of B-lines and fluid overload from previous data obtained in 61 paediatric patients undergoing cardiac surgery [2] . To detect a correlation of 0.3, with 5% significance and power of 80%, we aimed to recruit 82 patients. However, after 50 patients were studied, an interim analysis allowed us to adjust this figure to 78. It was a nonrandomized study in which we used non-probability, consequent sampling tests. All data are expressed as mean +/-standard deviation (SD) or median. The primary outcomes were evaluated using the chi-square test, Spearman's and Pearson correlation analysis reported with a level of significance of p < 0.05, two-tailed. The secondary outcomes were evaluated using the Student's test and chi-square test for the continuous and categorical variables, respectively. Simple descriptive and correlation analyses were performed in IBM Statistical Package for Social Sciences (SPSS), version 23 (IBM SPSS Statistics, Armonk, NY) and the R Project for Statistical Computing, version 3.6.2 (http://www.r-project.org/). Figure 5 shows the selection of participants in the study. Table 3 shows the correlation of the LUS score and oxygenation at the three study time points, T0, T1, and T2. Of note, there was a significant negative correlation with the change in LUS score at T1, and changes in PaO 2 /FiO 2 (p < 0.004). However, the change in the LUS score at T2 and PaO 2 /FiO 2 was not statistically significant (p < 0.81). There was no significant statistical correlation between ACC and CPB times with the LUS score. There is a progressive increase in both consolidation and pleural effusion in the first 24 hours. Table 4 shows the influence of certain procedures on changes in LUS from baseline. One finding relating to our primary objective was a statistically significant positive correlation of increasing LUS score between T0 and T2 and Extub T (p < 0.03). Looking at the secondary objectives, a higher positive fluid balance at one-hour post-surgery resulted in a significant increase in the LUS score between T0 and T2 (p < 0.03). Our goal was to see if it was practical to use LUS in cardiac surgery to show LUS signs of EVLW and demonstrate a correlation between LUS signs and oxygenation. The principle LUS sign was B-lines which were scored. Comparing preoperative and postoperative LUS scores and PaO 2 /FiO 2 , we found a significant negative correlation between B-lines and oxygenation. This is in agreement with a study of two groups of patients undergoing coarctation repair and treated with furosemide in which lung oedema and B-lines, scored by LUS, were less in the treated group [6] . Picano and Pellikka discussed that LUS could detect subclinical forms of pulmonary edema represented as B-lines [7] . Volpicelli et al. added that there was not always a correlation between elevated pulmonary artery occlusion pressure and the finding of a Bpattern with LUS [8] . LUS did have better specificity in the detection of a B-pattern for increased EVLW than by the Pulse Index Contour Continuous Cardiac Output (PiCCO) device (Pulsion Medical Systems, Feldkirchen, Germany). They noted that B-lines identifying EVLW could have a cardiogenic or non-cardiogenic mechanism. An increase in B-lines caused worsening oxygenation as measured by PaO 2 /FiO 2 and was associated with longer periods of ventilation. This finding is in agreement with a randomized control trial where LUS was used in congenital heart surgery in which two groups were compared: one with conventional ultrafiltration and the control which did not receive ultrafiltration [9] . At the end of the surgery, there was a negative correlation with PaO 2 /FiO 2 and LUS score. Another study was able to use LUS to identify patients with increased EVLW, demonstrated by B-lines and a decreased of PaO 2 /FiO 2 , which was correctable by dialysis [10] . Similar results were seen in other studies performed in adult patients undergoing haemodialysis, both of which showed that removal of volume in patients undergoing chronic dialysis resulted in a reduction of B-lines [11] [12] . This supports our finding of a high LUS score and worse oxygenation. Plus, an increase in LUS score (T0 to T2) was positively correlated with fluid management. This positive correlation is the most likely reason for the increased postoperative LUS scores being associated with longer time-to-extubation. Despite most patients being extubated by 24 hours, they actually had slightly lower PaO 2 /FiO 2 T2 = 328 versus T1 = 331. The lung LUS score at 24 hours was higher, explaining the deterioration in oxygenation. Thus, patient fluid management was again helped in the later postoperative period by using a technique that involved no radiation. Do these relatively novel uses of LUS help the patient's management by determining the EVLW status prior to surgery? Can this guide fluid management during surgery and in the ICU? A review article has mentioned the impact of LUS as a monitoring technique for cardiothoracic and vascular patients. The author emphasizes that LUS could improve perioperative outcomes [13] . More recently, an expert consensus highlighted the importance of the use of LUS in patients undergoing cardiac surgery with CPB who also suffer from coronavirus disease 2019 (COVID-19) [14] . While performing LUS, both pleural effusions and consolidation are seen. These secondary outcomes increased significantly postoperatively. Our incidence of postoperative pleural effusion of 34% was similar to the study by Touw et al. which found an incidence of 33% using LUS and 28% detected by chest x-ray after cardiac surgery [15] . Another advantage of LUS was the ability to detect and differentiate consolidation from the pleural fluid which is difficult with a chest x-ray. This was demonstrated by a prospective observational study where LUS was compared with a chest x-ray to diagnose postoperative pulmonary complications following cardiothoracic surgery [15] . On early admission to ICU, they found consolidation in 7.9% with LUS versus 0.0% with a chest x-ray. Overall, they found more postoperative pulmonary complications using LUS than a chest x-ray. The accuracy of LUS compared with chest x-ray impacts clinically on postoperative chest care. Alsaddique et al., on average, found 83 new respiratory abnormalities at three time points (after extubation, after removal of chest drains, and the day after surgery) [16] . The diagnosis, compared to chest x-ray, was changed in 52% of clinical episodes. The anaesthetists who performed the LUS were not blinded, which may have influenced the outcomes measured. Assessment of fluid balance was well-recorded but was not standardized for all conditions, so fluid boluses were at the discretion of the anaesthetist and intensivist. Regarding physical limitations, it was more difficult to perform the LUS on obese patients due to the thickness of the chest wall. Also, when the surgery involved the dissection of the left mammary artery, the upper left superior area of the lung was more challenging to assess because of subcutaneous emphysema. Postoperatively, the presence of dressings and drains also caused some variation of probe position to obtain a good ultrasound view. We did not have a gold standard to compare with the LUS. This study describes a portable, non-invasive alternative to chest x-ray in cardiac surgery to assess EVLW. Our results indicate that lung ultrasound is a feasible bedside, non-invasive investigation that it can be used to judge EVLW. EVLW affects oxygenation and thus provides valuable information regarding fluid balance, extubation, and enhances decision-making. Other methods, such as PiCCO, are more invasive and a comparison is warranted. We believe that this LUS method for the assessment of EVLW helps to determine the fluid management in the paradigm of the hypoxic patient which can have many causes. Human subjects: Consent was obtained by all participants in this study. King Abdullah International Medical Research Center, King Abdulaziz University, Jeddah, Saudi Arabia issued approval RYD-18-417780-17652. After reviewing the submitted proposal and related documents, the IRB has APPROVED the submission. . Animal subjects: All authors have confirmed that this study did not involve animal subjects or tissue. Conflicts of interest: In compliance with the ICMJE uniform disclosure form, all authors declare the following: Payment/services info: All authors have declared that no financial support was received from any organization for the submitted work. Financial relationships: All authors have declared that they have no financial relationships at present or within the previous three years with any organizations that might have an interest in the submitted work. Other relationships: All authors have declared that there are no other relationships or activities that could appear to have influenced the submitted work. Comparative diagnostic performances of auscultation, chest radiography, and lung ultrasonography in acute respiratory distress syndrome Assessment of extravascular lung water by ultrasound after congenital cardiac surgery update to the Society of Thoracic Surgeons and the Society of Cardiovascular Anesthesiologists blood conservation clinical practice guidelines International evidence-based recommendations for point-of-care lung ultrasound Furosemide: would it help to improve the lungs as evaluated by sonography and compliance during aortic coarctation surgery Ultrasound of extravascular lung water: a new standard for pulmonary congestion Lung ultrasound predicts well extravascular lung water but is of limited usefulness in the prediction of wedge pressure Effect of ultrafiltration on extravascular lung water assessed by lung ultrasound in children undergoing cardiac surgery: a randomized prospective study B-lines score on lung ultrasound as a direct measure of respiratory dysfunction in ICU patients with acute kidney injury Lung ultrasonography for the assessment of rapid extravascular water variation: evidence from hemodialysis patients Ultrasound assessment for extravascular lung water in patients undergoing hemodialysis. Time course for resolution Perioperative lung ultrasound for the cardiothoracic anesthesiologist: emerging importance and clinical applications Chinese Society of Anesthesiology expert consensus on anesthetic management of cardiac surgical patients with suspected or confirmed coronavirus disease 2019 Lung ultrasound compared with chest X-ray in diagnosing postoperative pulmonary complications following cardiothoracic surgery: a prospective observational study Repeated monitoring with transthoracic echocardiography and lung ultrasound after cardiac surgery: feasibility and impact on diagnosis The authors would thank Dr. Andrew Harper, Registrar in Cardiology, for his help with statistics and Dr. Wail Elamin, Consultant Cardiac Surgeon, for his patience while we were conducting the study.