key: cord-0815525-syp6hvbi authors: Ye, Haihang; Liu, Yaning; Zhan, Li; Liu, Yilin; Qin, Zhenpeng title: Signal amplification and quantification on lateral flow assays by laser excitation of plasmonic nanomaterials date: 2020-03-15 journal: Theranostics DOI: 10.7150/thno.44298 sha: 49a4be0b4de5e94f01fcc0d08b5fae0a7da54c15 doc_id: 815525 cord_uid: syp6hvbi Lateral flow assay (LFA) has become one of the most widely used point-of-care diagnostic methods due to its simplicity and low cost. While easy to use, LFA suffers from its low sensitivity and poor quantification, which largely limits its applications for early disease diagnosis and requires further testing to eliminate false-negative results. Over the past decade, signal enhancement strategies that took advantage of the laser excitation of plasmonic nanomaterials have pushed down the detection limit and enabled quantification of analytes. Significantly, these methods amplify the signal based on the current LFA design without modification. This review highlights these strategies of signal enhancement for LFA including surface enhanced Raman scattering (SERS), photothermal and photoacoustic methods. Perspectives on the rational design of the reader systems are provided. Future translation of the research toward clinical applications is also discussed. Lateral flow assay (LFA) is one of the most widely used point-of-care (POC) diagnostic tests and can be performed simply and rapidly without specially trained personnel [1] [2] [3] . LFA is also cost-effective that allows the easy access to large populations in resource-limited settings. A standard LFA is performed on a paper-based device, and its architecture consists of a sample pad, a conjugation pad, a capillary membrane, and an absorbent pad on a plastic backing card ( Figure 1A ). For a sandwich-type LFA, the presence of both test and control bands indicates a positive result ( Figure 1B) . Alternatively, competitive-type LFA is developed with opposite sensing mode. Details of this LFA format could be found in published work elsewhere [4] . Broader applications of LFA have been mainly limited by two factors: the lack of quantification and the low sensitivity, due to the weak optical signal from the detection agents [5] . In fact, the conventional LFA is intentionally designed for qualitative (i.e., yes or no) or semi-quantitative (refers to a color chart) tests so that the results could be read directly by naked eyes without additional instruments [6] . Thus, it only works for the tasks that involve a high concentration of analytes (e.g., ng/mL). These intrinsic limitations prevent the conventional LFA from becoming modern POC diagnostics. For example, the early-stage detection and management of severe and infectious diseases (e.g., [7] ) requires rapid and sensitive detection at low analyte concentrations. So far, the analytical performance of conventional LFA is often insufficient to be standalone tests. In the past decades, extensive efforts have been devoted to improving the sensitivity and quantification for LFA. Considering that the detection Ivyspring International Publisher agent is the key for the signal generation, one idea is to utilize them with stronger signals to improve the diagnostic performance of LFA [8, 9] . Therefore, different types of detection agents have been developed including organic dyes [10] , quantum dots [11, 12] , upconverting nanoparticles (NPs) [13] , latex beads [14, 15] , noble-metal NPs [16, 17] , carbon NPs [18, 19] , colloidal selenium [20] , and magnetic NPs [21] . Notably, these material innovations have advanced the limit of detection (LOD) into the level of pg/mL (vs. ng/mL of conventional LFA) and significantly broadened the applications. High-quality and scalable manufacturing of these nanomaterials is required to translate these techniques from the laboratory experiments to clinical use. Other strategies using additional reagents like metallic enhancement [22, 23] , enzyme-based catalytic reactions [24, 25] , and a combination of them [26] also lead to remarkable LOD improvement but add complexity to the LFA operation. An attractive strategy that amplifies signals based on the current LFA design has emerged in the last 5-10 years. The strategy mainly relies on the laser excitation of plasmonic gold NPs (GNPs) and the subsequently generated signal is much stronger than the color signal, resulting in the LOD enhancement. Note, GNPs are the most frequently used detection agents for in vitro diagnostics, especially in LFA. Like other plasmonic nanomaterials, GNPs feature a unique phenomenon called localized surface plasmon resonance (LSPR), making themselves ideal candidates in this revolution [27, 28] . The LSPR comes from the strong interaction between light and GNPs, where the surface electrons of GNPs oscillate collectively with the electric field of light [29] . It also leads to localized effects including enhanced electromagnetic field and eventually heating [30] [31] [32] . Taken together, applying laser on the GNPs-based LFA provides a new route to benefit its analytical performance without modifying the current architecture and operation. There are several advantages to this approach. Firstly, it keeps the simplicity and rapidness of LFA and doesn't add complexity in performing the assay. Secondly, it offers additional sensing modes to the conventional LFA. The as-generated signals from GNPs can also serve as indicators to determine target concentration. Thirdly, a more sensitive and quantitative detection could be achieved by a laser-reader system. Reading the color signal by naked eyes, especially for weak color change, inevitably causes inconsistent result in LFA [2] . With the assistance of a reader, robust and consistent results could be realized. Lastly, the laser-reader systems could potentially be miniaturized as handheld devices with all-in-one platform, which is highly desirable for POC diagnostics. To our knowledge, a review of this special topic on laser-induced signal amplification for GNPs-based LFA is not available and will provide intriguing insights from both scientific findings and clinical applications. In this review, we present the current status of LFA enhancement strategies that emerged over the past decade. Specifically, we will focus on methods that take advantage of laser excitation of plasmonic NPs and directly enhance signal based on the current LFA architecture, including surface enhanced Raman scattering, photothermal and photoacoustic methods ( Figure 1C ). For each method, we will introduce the principle of signal enhancement strategies, show its implementation on LFA and impacts on the sensitivity and quantification, examine the design of reader systems, and discuss potential limitations. We anticipate that the signal amplification techniques, as well as the perspectives provided in this article, serve as a guideline to explore novel sensing modes and detection approaches for the development of LFA towards highly sensitive POC diagnostics. Principle Surface enhanced Raman scattering (SERS) is a sensing technique that generates and amplifies the inelastic light scattering of molecules when they are adsorbed on the metals (e.g., gold, silver, and copper) [33] . This scattering signal could be enhanced (up to 10 orders of magnitude) by modulating the frequency of excitation light and LSPR of the metallic nanomaterials, relevant to the Stokes and/or anti-Stokes lines of molecules [34] . In SERS-based assay, specific tags made of nanostructures and molecules with known Raman fingerprints are the detection agents. Measuring the peak intensity of Raman molecules allows for the quantification of particle and analyte concentrations. Consequently, SERS has become a powerful tool in diagnostics due to its rapid, sensitive, and multiplexed outcomes [33] [34] [35] . Utilizing SERS for LFA has been explored as a highly sensitive assay platform since 2007 [36] . In SERS-LFA, the assay operation is identical to that of a conventional LFA, except for the tags' preparation. In the work by Hwang et al. [37] , Raman molecules and antibody-coated hollow GNPs were utilized as SERS tags for the LFA (Figure 2A ). For the SERS signal readout, a completed LFA strip was scanned in a standard Raman microscope system for the measurement, where the SERS peak intensity of test band was monitored for quantitative analysis. Using staphylococcal enterotoxin B (SEB) as a model, the authors performed SERS-LFA, conventional LFA, and ELISA for comparison. SEB is one of the bacterial superantigens secreted from Staphylococcus aureus that infects immune system profoundly and leads to a wide range of infectious diseases [38] . The result shown in Figure 2B demonstrates that SERS increased detection range and improved LOD of LFA by 10 4 -fold, and it was even 10 3 -fold lower than that of ELISA. Particularly, for each strip characterization, a focused area (200 μm × 800 μm) of test band was used to collect the SERS signal, while the control band was tested for verification (see the inset in Figure 2B ). Also, due to the uneven distribution of SERS signal on the test band, the average intensity of scanned regions was further used for the quantitative analysis. The concept of combining SERS with LFA for nucleic acids detection was also reported by the same group [39] , and soon after that, this assay platform has been widely extended to different targets, including disease biomarkers [40] and pathogens [41] . One major factor leads to highly sensitive SERS-LFA is deploying NPs with stronger plasmonic coupling effect. For example, nanostructures with "hot spots" were reported to enhance SERS signals, including plasmonic NPs with rough surface, coupled NPs with nanogaps, and multibranched nanostructures [42] [43] [44] . Also, the specific interaction (e.g., electron transfer) between the Raman molecules and the NPs allows further amplification of SERS signal [34] . Meanwhile, the stability of Raman signals is another direction that requires carefully design of the SERS tags. For instance, NPs with high uniformity and protection layers enable evenly distributed signal and avoid the loss of Raman reporters, respectively [45, 46] . Therefore, optimizing the shape and composition of the plasmonic NPs has great promise in the development of SERS-based diagnostics for the amplified and robust signal readouts. SERS can also lead to multiplexed detection on LFA. Specifically, SERS tags encoded with different Raman molecules are conjugated to the detection antibodies for multiple targets [47, 48] . For example, Doering et al. demonstrated for the first time using Nanoplex Biotags (Au@SiO2 NPs, commercially available from Oxonica, Inc.) for the multiplexed detection of Flu A, Flu B, and respiratory syncytial virus on a standard LFA [36] . However, combining multiple targets in one test band, the as-obtained SERS spectrum could show overlapped or close peaks and may impact on the sensitivity of LFA [49, 50] . Arranging parallel test bands on the membrane could also achieve multiplexed detection, where each band associates to identify one of the targets [51]. This inevitably increases the assay time and reduces the signal throughput [52] . In addition, construction of microarray on LFA strips offers a promising solution to shorten the sample-to-answer time. For example, Zhang et al. demonstrated a multiplexed detection of respiratory tract infection pathogens (up to 11) by grouping two SERS tags and a 2×3 microarray as test dots on the LFA [53]. Collectively, further work could put more efforts in the nanostructure design, strip construction, and Raman reporter's selection for multiplexed detection on SERS-LFA. As a proof-of-principle, bulky Raman microscope system was used to measure the SERS signal of LFA, yet impractical for POC deployment. Recently, Tran et al. reported a portable SERS reader designed for rapid scanning of the LFA strips [54] . The compact setup mainly composed of an optical fiber probe and a 785 nm diode laser ( Figure 2C ). Taking advantage of the line focus of optical fiber probe, the laser illumination covers the entire width of strip and moves across step by step (0.1 s for each step and 50 steps per band), achieving 5 s acquisition time for the test band (4 mm × 0.8 mm) within an individual scan. In addition, this compact SERS-LFA platform showed improved diagnostic performance for the human chorionic gonadotropin (hCG) detection. Notably, in the work by Tran et al., Au-Ag core-satellite NPs were used as detection agents, which provided 4-fold visual LOD enhancement over the commercial LFA kits. While for SERS detection, the reader further lowered the LOD by 4-fold, thereby 16-fold improvement in total over the commercial LFA kit ( Figure 2D ). There are several limitations of SERS-LFA technique. Firstly, special design of the SERS tags with strongly enhanced local electromagnetic field are required to generate sufficient and robust Raman signals. For example, Au@SiO 2 core-shell NPs, hollow GNPs, Au-Ag core-satellite NPs have been used in the above-mentioned work [36, 37, 54] . This could potentially lead to complexity and difficulty in SERS molecule encoding, antibody conjugation, and maintaining shelf stability. Secondly, the trade-off occurs between signal intensity and data acquisition settings. For instance, point scanning with long acquisition time favors for strong Raman signal. However, this compromises the working efficiency and only samples a limited fraction of the test band, which could lead to under-sampling and inconsistent results from test to test (i.e., low reproducibility). This issue also exists in some commercially available SERS readers (e.g., Snowy Range 'CBEx' Raman spectrometer, Laramie, USA) [55] . In contrast, increasing sampling area and reducing acquisition time result in significantly inferior performance. For instance, Hwang et al. reported 10 4 -fold improvement by point scanning part of the test band (200 μm × 800 μm) with long acquisition time (6 min), while Tran et al. reported 4-fold improvement by line scanning the whole test band (4 mm × 0.8 mm) with short acquisition time (5 s). In addition, the line scanning requires more powerful laser (120 mW) compared with the point-scanning Raman microscope system (3 mW). Thermal contrast amplification (TCA) The heat generation of GNPs has been widely studied in the area of photothermal therapy for cancer treatment [56] [57] [58] [59] . Briefly, when the LSPR of GNPs matches with the laser wavelength, they can efficiently convert light energy (photons) into heat. The amount of heat generation could be estimated by the following equation: Q= NQnano= NC abs I where the total heat generation (Q, W/m 3 ) is the accumulated contribution of individual GNP (Q nano , W) and the particle concentration of GNPs (N, number/m 3 ). Q nano could be further written as the product of GNP absorption cross-section (C abs , m 2 ) and laser intensity (I, W/m 2 ). Clearly, the heat is proportional to the number of GNPs and laser energy applied within the detection region, and the C abs is associated with the physical parameters of GNPs (e.g., size and shape) [32] . This sets the basis to use the heat generation from GNPs and integrate thermography techniques for potential diagnostic applications. Qin et al. demonstrated for the first time using thermal response of GNPs to improve the LFA [61]. Essentially, a completed LFA strip was irradiated with a 532 nm laser (power = 0.01 W) to activate the GNPs and the thermal contrast signal was recorded by an IR camera ( Figure 3A ). The thermal analysis of test band gave quantitative results as a function of the GNP concentrations. The analytical performance of FDA-approved LFA strips for detecting cryptococcal antigen (CrAg) was evaluated through the thermal contrast signal. CrAg testing is urgently required for cryptococcal meningitis diagnosis, especially in immunocompromised adults [62] . Figure 3B shows the TCA produced a 32-fold enhancement in the detection sensitivity and extended detection dynamic range over the visual detection. Note the blue arrow marks the high dose "hook" effect with decreased visual and thermal intensity, which can be addressed by diluting the target sample or engineering the format of strip [6] . The TCA technique was further validated in clinical cerebral spinal fluid samples with known CrAg titers from patients with and without cryptococcal meningitis. Recently, clinical cohort study was performed using the commercial CrAg LFA kits (Immy, Inc., USA) assisted with TCA technique [63] . The shape and size of the GNPs played an important role in improving their photothermal property and thereby the performance of diagnostics. Changing the spherical GNPs into gold nanorods (GNRs) or gold nanoshells (GNSs) could largely increase the Cabs per particle volume [64] . As a result, under same condition (i.e., particle concentration and laser power), GNRs produce about 10-fold more heat than the spherical GNPs and GNSs when normalized against the particle volume. Moreover, when combined with low-absorbing substrates as the backing materials (e.g., glass and plastic) and higher laser power (i.e., 0.01 W to 1 W), GNRs-based TCA-LFA could have the potential to achieve 10 4 -fold improvement over the visual LOD of LFA [61] . In addition, Hu et al. reported employing gold nanocages with superior photothermal conversion efficiency as detection agents for TCA-LFA, where a 6-fold enhancement of the LOD has been achieved compared with the visual LFA [65]. Zhan et al. also studied the size impact of GNPs on the sensitivity of LFA [66] . Importantly, the size of GNPs not only affects their optical and thermal properties, but also influences the migration speed and antibody binding events within the membrane. By modelling these key parameters (i.e., size and concentration of GNPs, migration rates, binding reaction, and diffusion), Zhan et al. found that larger GNPs could improve the assay performance due to more antibodies on the surface (favoring the binding reaction) and size-dependent properties (larger size resulting in stronger signal generation). For example, 100 nm GNPs yield a 256-fold sensitivity enhancement under the TCA detection mode compared to the colorimetric signal of 30 nm GNP-based LFA. However, even larger GNPs (e.g., 400 nm) would have difficulties in migrating across the strip due to the slower diffusion rates. This inevitably decreases GNP capture and thus the LFA sensitivity. Similar investigation of size impact on the LOD of LFA has also been reported by Loynachan et al. [17] . Development of benchtop and portable devices is critical to further translate the technology. The initial detection system reported in [61] is only available in a research lab (i.e., a large laser system on an optical table) with manual control and a simple reading algorithm. In a follow-up study, the same group developed a benchtop TCA reader prototype (46 cm × 34 cm × 34 cm size, 11.7 kg weight, Figure 3C ) that is low-cost and compact with automatic data acquisition and analysis [67] . The overall design of the laser-reader system was shown in Figure 3D . In the benchtop device, a continuous wave (CW) laser was employed, of which the cost was significantly reduced but the performance was comparable to the original research laser (Spectra-Physics, Millennia Vs) under the same output power. Other improvements over the research system include automation of a stepper motor and an optical shutter through LabVIEW, as well as the LFA-holding cassettes that could align LFA strips of different sizes and geometries under the laser for reproducible reading. However, the IR camera with software for signal reading and data analysis wasn't changed due to the requirement of spatial resolution and user interface. Based on this benchtop device, a two-stage algorithm was used ( Figure 3E ): 1) the temperature rise was obtained by capturing multiple points (vs. single point in previous work [61] ) of test band subtracting the background temperature rise (outside test band); 2) area under curve (AUC) analysis of the TCA signal pattern was performed for the data reduction and quantitative results. The development of a handheld and portable device for TCA was conceptualized and initial assessment on the individual reader components such as a portable laser and a cheaper IR sensor was performed. Further work has been undergoing to build and test a POC device based on the TCA technique. To validate the analytical performance of benchtop device, commercially available LFA kits for three diseases (influenza A, malaria, and C. difficile) were used. Both qualitative (i.e., subjective evaluation of TCA data) and quantitative (i.e., AUC analysis) results could be obtained (for simplicity, only influenza A kits were shown in Figure 3F ). The TCA reader showed 8-fold enhancement over the visual recognition for all cases. For the quantitative analysis, a prominent linear trend was fitted, indicating the correlation of signal to the target concentration in the sample. In addition, the benchtop TCA reader was carried out to perform test on clinical samples, demonstrating a 4-to 8-fold improvement of analytical sensitivity. Importantly, TCA reader is a simple add-on reader for commercial LFAs without any additional modification. Although there are numerous benefits of TCA reader, some limitations need to be addressed before rigorous field tests. One is the reading time for each test. Currently, 10-20 min are required for data acquisition and analysis, which should ideally be shortened to less than 3 min per test. Also, due to the random distribution of GNPs in test band and pointscanning of the TCA method, reproducible measurements must be carefully considered. Therefore, it is important to develop a portable reader with robust and consistent results since the precise temperature measurements are used as the "thermal" signal. Thermophotonic lock-in imaging (TPLI) is a thermography testing technique for industrial evaluation of materials and devices [68] . In this technique, a low-power, continuous, and intensitymodulated laser is introduced to produce a controlled thermal wave inside the feature of interest. The lock-in demodulation evaluates the detected signal that carries information of sample inhomogeneities using the excitation light as reference [69] . In other words, the absorbers located at different depths inside the feature possess different optical scattering and absorption coefficients, contributing to the depthintegrated IR signal. Recent studies have successfully demonstrated the TPLI application to the biological samples such as early detection of dental caries in human teeth [69, 70] . When coupled with LFA, the TPLI provides a promising method utilizing thermal response of GNPs as the indicators. Interestingly, the TPLI is capable to inspect the depth of a feature by controlling the laser modulation frequency [68] . This ability enables the detection of GNPs trapped on surface and inside the membrane. In a recent work, Ojaghi et al. developed a long-wave infrared TPLI system for the thermal interpretation of LFA strips [71] . As shown in Figure 4A , the working scheme was to use a laser to first excite the region of interest (ROI) covering both control and test bands for the generation of thermal waves (i.e., Planck radiation), which was subsequently detected by an IR camera. Due to the spatial distribution of GNPs at various layers of the membrane, the diffusive thermal field was altered and resulted in a depth-integrated signal. Therefore, a phase shift was formed when the inner thermal wave reached the surface and contributed to the thermal radiation. Simultaneously, amplitude change of the radiometric signal was induced by the subsurface absorption of light that can also be used to quantify the concentration of GNPs and the analyte. TPLI was then tested to enhance LFA performance. Figure 4B shows the setup for TP signal generation, where the testing strip was mounted on a stage to secure the position and height. A multifunctional data acquisition system was designed to generate analog reference and acquire data synchronously under different excitation cycles ( Figure 4C ). The as-obtained TP signal was then proceeded via a standard quadrature demodulation/ lock-in analysis to decipher amplitude and phase information. Typical TP phase and amplitude images of LFA strip were shown in Figure 4D at 2 Hz of laser frequency, where the control and test bands and the adjacent background (red box) can be resolved. Due to the different number of GNPs accumulated in those three regions, the corresponding thermal contrast could be observed in both images. Therefore, the variation of contrast in the test bands from different strips was used to correlate with the concentration of GNPs and analyte. Under the optimized modulation frequency (2 Hz), the average normalized phase signal decreases quantitatively as a function of hCG concentration ( Figure 4E ). Statistically, 0.2 mIU hCG in LFA could be detected through TPLI technique, while only 2 mIU hCG was reached by visual interpretation or optical reader. In addition to the sensitivity and quantification, large-field and simultaneous measurements of multiple LFA strips is possible and could be accomplished in a short time (i.e., 10 s at 2 Hz modulation frequency). The latest report of this technique was performed in a benchtop system (i.e., on an optical table, Figure 4B and C). The authors mentioned that the IR camera can be potentially replaced by cell-phone attachment IR cameras to reduce the cost and size of the reader [71] . More information about reader development is not available. For further development of devices, the following constrains of current technique need to be addressed. Firstly, the instrumental cost needs to be reduced. In the present demonstration [71], IR camera, laser, multifunctional data acquisition board are required to collect the signal, and a computer is used to process the data. Secondly, the LOD improvement strongly depends on the laser modulation frequencies. Optimal modulation frequency that yields thermal diffusion length commensurate with the thickness of the LFA needs to be experimentally tested. This may pose a challenge when different types of LFA kits are tested. Photothermal laser speckle imaging (PT-LSI) Laser speckle imaging (LSI) is an interferometric technique to measure the optical contrast generated by the light scattering of a moving sample [72] . When a laser illuminates a diffuse material, the highly coherent light produces granular interference pattern known as speckle [73] . In a typical LSI, a digital camera records this laser speckle under very short exposure time (several milliseconds), recording the surface intensity pattern of light from a scattering medium. This intensity-fluctuation profile, through a simple Fourier transformation, enables statistical calculation and mapping of species dynamics [74] . Collectively, many applications have been proposed and implemented in the fields of neuroscience, dermatology, and ophthalmology [75] [76] [77] . Photothermal laser speckle imaging (PT-LSI) has advanced the conventional LSI with improved depth resolution by incorporating a pulse laser. This leads to the selective excitation of absorbers and allows for highly sensitive detection [78] . Song et al. have recently demonstrated the use of PT-LSI for LFA [79] . Due to the multiple layered structure of LFA strips, the probe light scatters randomly and forms speckle patterns. The working principle, as shown in Figure 5A , takes advantages of a PT laser with 532 nm beam to specifically excite the GNPs on membrane. As a consequence, the GNPs generate heat and change the speckle pattern of LFA membrane by the scattered light of 780 nm probe laser. Instead of using IR camera as the sensor, the speckle pattern change was monitored by an optical sensor (i.e., CMOS camera), which reduces cost compared with IR cameras. An optical chopper is employed to modulate the intensity of PT light to minimize external noise, such as laser intensity variation. The excited GNPs generate heat that alters the refractive index and causes thermal deformation of the membrane, resulting in the speckle pattern change. This change is associated with the number of GNPs reside, which can be used to quantify the target concentration. A custom-built program implemented in MATLAB was designed to process the PT-LSI signal. The analytical procedure is outlined in Figure 5B (top to bottom) . Firstly, the pixel intensity of each PT-LSI image obtained at different time periods is characterized by a fluctuation at the same frequency of the PT light modulation. Note, the presence of GNPs gives a much stronger signal than the background signal from LFA membrane. Secondly, the intensity fluctuation profile is Fourier transformed into magnitude as a function of frequency, which is further mapped into a PT-LSI image based on the corresponding pixels. Lastly, the averaged PT-LSI signals, referred to as "PT-LSI output" over the ROI (i.e., control and test bands), quantify the concentration of GNPs and analytes. As evidenced in Figure 5C and D, the PT-LSI result showed enhanced analytical performance over the colorimetric signal in quantifying the concentration of GNPs solution and CrAg sample. The LOD of the PT-LSI coupled LFA was 125fold and 68-fold lower than that of the colorimetric LFA for detecting GNP and CrAg, respectively. As mentioned by the authors, the PT-LSI reader can be readily miniaturized to a portable size with inexpensive consumer-grade components [79] . For instance, the optical chopper for PT light modulation can be replaced by diode laser current modulation with a microcontroller, and the high-speed CMOS camera can be substituted with webcams that is less than $20. In addition, the PT light source can be a laser pointer. Alternatives such as using high-speed field programmable gate array devices and pulsed or coded PT light illumination were also proposed to increase the data analysis speed over the current results (i.e., 2.5 min). The robustness of using laser pointers and web camera as the key components for portable reader should be rigorously tested. Especially, the power stability of laser pointer will be a major obstacle for consistent performance during long term usage. In addition, the data processing for speckle images of PT-LSI technique should also be considered for resource-limited settings. Principle Photoacoustic (PA) effect is another interesting phenomenon induced by the laser absorption of chromophores and pressure wave generation [80] . Detection method using PA signal was first developed in the 1970s [81] . Essentially, the PA technique provides quantitative results based on three steps, including the optical absorption, the energy conversion from light to heat, and the thermal expansion of the adjacent media that produces acoustic waves as PA signal [82] . As a result, the PA signal increases with the absorbed energy and indicates the optical absorption of a sample. In addition, the PA imaging has deeper penetration due to the ultrasound transmission and sensitive detection, compared with limited light penetration in optical imaging [83] . Taken together, the PA technique has been very attractive to the analytical community and its integration with current diagnostic platforms (e.g., ELISA) [82] is promising to move from the laboratory research to preclinical and clinical realities [83, 84] . Zhao et al. first explored the combination of PA technique with LFA [85] . Figure 6A shows that, when illuminated by a CW laser beam, the GNPs captured within test/control bands generate PA signal due to the thermal expansion of the adjacent air. Meanwhile, the different density of GNPs at the test band leads to the amplitude change of PA signal, which indicates the analyte concentration. To ensure the precise and quantitative measurements, the LFA strip was enclosed in a small-volume and air-tight chamber with minimized vibration from the environment and the strip itself (see Figure 6B ). Also, two detection modes were developed, where the "chop mode" employed an optical chopper to modulate the laser intensity and the "scan mode" used a rotating polygonal mirror for the scanning across the ROI. Notably, the peak-to-peak value of the signals ( Figure 6C and D) was marked as the PA signal amplitude and further used to calculate the analyte concentration. Due to the adsorption of light by the strip itself, a strong background signal was observed in the "chop mode" (blue trace in Figure 6C ), while in the "scan mode", the background signal was reduced (blue trace in Figure 6D ). This is because, without chopping the laser, the LFA strip absorbs a constant amount of the excitation light during the scan and the laser stimulation generates a GNP-specific signal when scanning across the test band. Using CrAg LFA kits as an example, PA method could significantly enhance the sensitivity over the colorimetric detection. Figure 6E shows the dose-response curves of the colorimetric analysis, chop mode, and scan mode of PA detections, giving LOD of 1.1 ng·mL -1 , 0.57 ng·mL -1 , and 0.010 ng·mL -1 , respectively. These results clearly demonstrated that the PA technique offers a powerful means to amplify the signal, enabling a more sensitive (110-fold enhancement) and quantitative analysis for LFA. The authors proposed several options to miniaturize the size and reduce the cost of PA detection system [85] . For instance, it is technically available to replace laser with a LED that matches the absorption of the GNPs and integrate the light source, microphone, the detection chamber, and readout circuit into a palm-size box. Recently, Zhang et al. proposed a miniaturized PA cell for testing of blood glucose on paper-based devise [86] . The Teflon-made PA cell is a cubic structure with 40 × 20 × 20 mm in dimension, where a sample holder, a cylinder chamber, and a microphone are configurated together inside for signal generation and acquisition. The small size of the chamber (~0.2 cm 3 ) prevents the sound loss during the testing. The whole cell is sealed to enable a stable environment for minimal fluctuation of signals. Future work may extend to other paper-based assays (e.g., GNPs-based LFA). In the work by Zhao et al., the LFAs were dried for 15 min before tested by PA method [85] . However, it is noted in most commercially available LFA kits, the results should be read when the strip is wet for more accurate interpretations. It is important to validate this technique for wet LFA readings since low percentage of the acoustic wave is able to travel through water-air interface. Again, reproducibility issue raises the users' concerns due to the intrinsic point-scanning reading of PA technique. In this article, we have highlighted the laserinduced signal amplification techniques on GNPsbased LFA reported in the past decade. GNPs can be excited by the laser and convert the absorbed energy into enhanced electromagnetic field or heat due to the LSPR. Such responses of GNPs provide new sensing modes that have been successfully integrated on LFA, including SERS, thermal contrast, thermophotonic, speckle, and photoacoustic signals. Different reader systems including hardware (e.g., laser source and detector) and software (e.g., signal acquisition and data proceeding) have been introduced for each technique implementation. Compared with the colorimetric readouts of LFA, those techniques show improved analytical performance upon the sensing of analytes. Promising as they are in this technological development, we are expecting to witness more competing products in the coming decade. These signal amplification strategies are more straightforward than the colorimetric enhancement strategies since the latter one requires specifically designed detection agents (e.g., enzymes coated GNPs) or additional reagents for improved signal readouts. As clearly illustrated from the abovementioned examples, the laser-assisted techniques detect the signal from a completed strip without extra assay operation and can be readily implemented on commercially available LFA kits. However, there are several limitations: 1) for SERS-LFA, it suffers from the high assay expenses and special SERS tags preparation; 2) for the photothermal-related detection, the bulky instrumentation needs to be further improved with lower-cost components; 3) clinical assessment is also highly demanded to evaluate the enhanced sensitivity versus the likelihood of false-positives for all techniques; and 4) the point-focus scanning (e.g., TCA and PA methods) needs to be optimized for rapid and robust readouts. The comparison of each method viewed from other aspects has been summarized in Table 1 . With these developments for LFA signal enhancement, we envision that diagnostic performance of an assay is one of several critical parameters towards practical applications. Particularly, minimizing non-specific binding and increasing specific binding at test bands of LFA strips are the key to reduce background signals and interpret accurate results at low target concentrations (vs. false positives). Other factors such as the optimization of whole detection system, including signal generation, miniaturization, cost, operation time, automation, and data analysis, should also be considered from the POC perspective [87] . Toward this end, the development of devices may be divided into three stages: 1) initiate research study to demonstrate the feasibility of integrating new detection techniques on LFA strips and the research outcomes could serve as a guideline to develop portable systems; 2) prototype a benchtop system consisting of lower-cost and smaller components, which offers on-demand tests and can be installed in hospitals or central referral laboratories; and 3) develop a handheld system that can be used in a wide range of environmental settings and fulfill the need of on-site decision making with high sensitivity. Such device development is an important step to translate the innovation from benchtop to bedside [88] . Licensing techniques from academic institutions to startup companies or incubators can further translate these findings into the clinics yet remains another challenge (i.e., "valley of death" [89]). As a good reference, the development of fluorescencebased LFA directs a pathway for the researchers who are interested to pursue further clinical translation, such as LFA manufacturing, fluorescence label design, and instrument optimization. For example, the deployment of upconverting NPs in LFA reduces the background signal from the strip [90] ; and there are many commercially available fluorescence readers in the market. For future POC diagnostics, the highly flexible formats of LFA allow further integration of novel materials and techniques. For instance, GNPs with varied shapes and structures provide a simple yet efficient way for the sensitivity and accuracy improvement of the LFA, while it's now feasible to prepare them in a controlled manner [91, 92] . It is promising to apply them into LFA for new signal-transducer principles and substantial signal enhancement. While for the size-dependent signal transduction, its response usually increases with the GNPs size. However, the membrane structure of LFA strips traps the large particles, and it leaves the assay incomplete. Therefore, rather than enlarging the size of GNPs for stronger signals, the priority should be put in choosing NPs with proper size without difficulties in completing the assay. Also, the multiplexing of LFAs is a critical area for the development of the POC diagnostics. In this case, the creation of pads or other platforms and efficient conjugation events will be of great importance [3, 93, 94] . Microfluidic platforms that are able to precisely manipulate the flow rate of sample and the migration of probes and targets allow for high-throughput screening applications. There will be some potential opportunities to combine the advantage of these two platforms [95, 96] . Smartphone has been developed as a platform for POC diagnostics in recent years, offering great opportunities for delivering healthcare to resource-limited settings due to its availability [97] . The integrated components (e.g., camera, chips, and add-on thermal camera from FLIR ® ) of smartphone are extremely suitable for signal enhancement and detection of LFA [98-100]. While not a focus in this paper, enhancing the optical signal of GNPs in LFA by increasing the probe density around the analytes like self-assembly and aggregation has been well documented in recent papers [101] [102] [103] . Ultimately, we hope that this article can be a valuable source to the communities in academia and industry for future work in this important and emerging field. Ag: silver; Au: gold; Pt: platinum; SiO 2 : silica; ELISA: enzyme-linked immunosorbent assay; FDA: Sol particle 1. immunoassay (SPIA) Paper-based nanobiosensors for diagnostics Fluorescent probe-based lateral flow 3. assay for multiplex nucleic acid detection A 4. new kind of highly sensitive competitive lateral flow immunoassay displaying direct analyte-signal dependence. Application to the determination of the mycotoxin deoxynivalenol Emerging strategies to 5. develop sensitive AuNP-based ICTS nanosensors Lateral flow assays: Principles, designs and 6. labels A novel coronavirus 7. from patients with pneumonia in China Template regeneration in 8. galvanic replacement: A route to highly diverse hollow nanostructures Membrane-based lateral flow 9. immunochromatographic strip with nanoparticles as reporters for detection: a review A dye-assisted paper-based 10. point-of-care assay for fast and reliable blood grouping A fast and sensitive 11. immunoassay of avian influenza virus based on label-free quantum dot probe and lateral flow test strip Rapid and sensitive detection 12. of protein biomarker using a portable fluorescence biosensor based on quantum dots and a lateral flow test strip Household fluorescent lateral 13. flow strip platform for sensitive and quantitative prognosis of heart failure using dual color upconversion nanoparticles Dry-reagent nucleic acid biosensor based on blue dye 14. doped latex beads and lateral flow strip Two-color lateral flow assay for multiplex 15. detection of causative agents behind acute febrile illnesses Platinum-decorated 16. gold nanoparticles with dual functionalities for ultrasensitive colorimetric in vitro diagnostics Platinum nanocatalyst amplification: redefining the gold standard for lateral flow immunoassays with ultrabroad dynamic range Immunochromatographic colloidal carbon-based assay for detection of methiocarb in surface water Carbon 19. nanotube-based lateral flow biosensor for sensitive and rapid detection of DNA sequence Lateral flow test strip 20. based on colloidal selenium immunoassay for rapid detection of melamine in milk, milk powder, and animal feed Lateral flow 21. immunochromatographic assay for sensitive pesticide detection by using Fe3O4 nanoparticle aggregates as color reagents NutriPhone: a 22. mobile platform for low-cost point-of-care quantification of vitamin B12 concentrations Enhanced sensitivity of lateral flow tests using a two-dimensional paper network format Ultrasensitive 24. nucleic acid biosensor based on enzyme-gold nanoparticle dual label and lateral flow strip biosensor Enhanced lateral flow 25. immunoassay using gold nanoparticles loaded with enzymes Dramatically enhanced 26. immunochromatographic assay using cascade signal amplification for ultrasensitive detection of Escherichia coli O157: H7 in milk Gold nanomaterials at work in 27. biomedicine Why gold nanoparticles are more precious than pretty 28. gold: noble metal surface plasmon resonance and its enhancement of the radiative and nonradiative properties of nanocrystals of different shapes The optical properties of metal 29. nanoparticles: The influence of size, shape, and dielectric environment Approaching the electromagnetic mechanism of 30. surface-enhanced Raman scattering: from self-assembled arrays to individual gold nanoparticles Plasmonic photothermal 31. therapy (PPTT) using gold nanoparticles Thermophysical and biological responses of gold 32. nanoparticle laser heating SERS-activated platforms for 33. immunoassay: probes, encoding methods, and applications Single-molecule and single-nanoparticle SERS: from 34. fundamental mechanisms to biomedical applications Multiplex in vitro detection using SERS SERS as a foundation for 36. nanoscale, optically detected biological labels Application of a SERS-based lateral flow 37. immunoassay strip for the rapid and sensitive detection of staphylococcal enterotoxin B The pathogenesis of Staphylococcus aureus in autoimmune diseases A SERS-based lateral flow assay 39. biosensor for highly sensitive detection of HIV-1 DNA Quantitative and 40. ultrasensitive detection of multiplex cardiac biomarkers in lateral flow assay with core-shell SERS nanotags Highly sensitive 41. detection of high-risk bacterial pathogens using SERS-based lateral flow assay strips Rough surface Au@Ag core-shell 42. nanoparticles to fabricating high sensitivity SERS immunochromatographic sensors SERS-based lateral flow immunoassay of troponin I by using gap-enhanced Raman tags Bisphenol A detection using gold nanostars in a SERS 44. improved lateral flow immunochromatographic assay Quantitative and 45. ultrasensitive detection of multiplex cardiac biomarkers in lateral flow assay with core-shell SERS nanotags SERS-based lateral flow 46. assay for quantitative detection of C-reactive protein as an early bio-indicator of a radiation-induced inflammatory response in nonhuman primates Engineered noble-metal nanostructures for in vitro 47. diagnostics Design of SERS nanotags for multiplexed lateral flow immunoassays Simultaneous detection of 49. dual nucleic acids using a SERS-based lateral flow assay biosensor Hamad-Schifferli K. Surface-enhanced Raman spectroscopy-based sandwich immunoassays for multiplexed detection of zika and dengue viral biomarkers Multiplex lateral flow detection and binary encoding 51. enables a molecular colorimetric 7-segment display Quantitative detection of 52. multiplex cardiac biomarkers with encoded SERS nanotags on a single T line in lateral flow assay Rapid and ultrasensitive 53. quantification of multiplex respiratory tract infection pathogen via lateral flow microarray based on SERS nanotags Rapid, quantitative, 54. and ultrasensitive point-of-care testing: a portable SERS reader for lateral flow assays in clinical chemistry Sensitive 55. SERS nanotags for use with a hand-held 1064 nm Raman spectrometer Gold nanoparticle-mediated 56. photothermal therapy: current status and future perspective In vivo analysis of biodegradable liposome gold nanoparticles as efficient agents for photothermal therapy of cancer Laser-induced tissue hyperthermia mediated by gold nanoparticles: toward cancer phototherapy Gold nanoparticles: interesting 59. optical properties and recent applications in cancer diagnostics and therapy Rapid colorimetric 60. identification and targeted photothermal lysis of Salmonella bacteria by using bioconjugated oval-shaped gold nanoparticles Significantly 61. improved analytical sensitivity of lateral flow immunoassays by using thermal contrast Adult 62. meningitis in a setting of high HIV and TB prevalence: findings from 4961 suspected cases Multisite validation of cryptococcal antigen lateral flow assay and quantification by laser thermal contrast Quantitative comparison of photothermal heat generation between gold nanospheres and nanorods Calorimetric lateral flow 65. immunoassay detection platform based on the photothermal effect of gold nanocages with high sensitivity, specificity, and accuracy The role of 66. nanoparticle design in determining analytical performance of lateral flow immunoassays Thermal 67. contrast amplification reader yielding 8-fold analytical improvement for disease detection with lateral flow assays Thermophotonic radar imaging: an 68. emissivity-normalized modality with advantages over phase lock-in thermography Thermophotonic lock-in imaging of 69. early demineralized and carious lesions in human teeth First step toward translation of 70. thermophotonic lock-in imaging to dentistry as an early caries detection technology High-sensitivity interpretation of 71. lateral flow immunoassays using thermophotonic lock-in imaging Laser speckle contrast imaging in biomedical optics Laser speckle imaging 73. with an active noise reduction scheme Laser speckle contrast imaging: theoretical and practical limitations Laser speckle imaging based on photothermally driven 75. convection Laser speckle imaging for monitoring blood flow 76. dynamics in the in vivo rodent dorsal skin fold model Noninvasive blood flow imaging 77. for real-time feedback during laser therapy of port wine stain birthmarks Photothermal laser speckle imaging. 78 Highly sensitive paper-based 79. immunoassay using photothermal laser speckle imaging Multiwavelength photoacoustic imaging and plasmon resonance coupling of gold nanoparticles for selective detection of cancer Photoacoustic spectroscopy with condensed 81. samples A photoacoustic immunoassay 82. for biomarker detection In vivo 83. magnetic enrichment and multiplex photoacoustic detection of circulating tumour cells Detection of aqueous glucose based 84. on a cavity size-and optical-wavelength-independent continuous-wave photoacoustic technique Nanoparticle-based 85. photoacoustic analysis for highly sensitive lateral flow assays A miniaturized photoacoustic device with 86. laptop readout for point-of-care testing of blood glucose Emerging technologies for 87. next-generation point-of-care testing Prospects for 88. point-of-care pathogen diagnostics using surface-enhanced Raman scattering (SERS) Public sector seeks to bridge 'valley of death Upconversion fluorescent 90. strip sensor for rapid determination of Vibrio anguillarum A simple millifluidic 91. benchtop reactor system for the high-throughput synthesis and functionalization of gold nanoparticles with different sizes and shapes A droplet-reactor system capable 92. of automation for the continuous and scalable production of noble-metal nanocrystals Multiplex analysis on a 93. single porous hydrogel bead with encoded SERS nanotags Multiplex lateral-flow test 94. strips fabricated by two-dimensional shaping An integrated rotary 95. microfluidic system with DNA extraction, loop-mediated isothermal amplification, and lateral flow strip-based detection for point-of-care pathogen diagnostics Diagnostics for the 96. developing world: microfluidic paper-based analytical devices Advances in smartphone-based point-of-care diagnostics Automated 98. low-cost smartphone-based lateral flow saliva test reader for drugs-of-abuse detection Performance improvement of the one-dot lateral flow 99. immunoassay for aflatoxin B1 by using a smartphone-based reading system A 100. simple and compact smartphone accessory for quantitative chemiluminescence-based lateral flow immunoassay for salivary cortisol detection Self-assembled 101 ZQ is listed on patents related to thermal contrast amplification and has the equity interest in Vigilant Diagnostics.