key: cord-0833740-i1iznz8a authors: Onweni, Chidinma L.; Venegas-Borsellino, Carla P.; Treece, Jennifer; Turnbull, Marion T.; Ritchie, Charles; Freeman, William D. title: The Power of Mobile Health: The Girl With the Gadgets in Uganda date: 2021-04-23 journal: Mayo Clin Proc Innov Qual Outcomes DOI: 10.1016/j.mayocpiqo.2021.01.001 sha: db52111736f1299aa6ccac7976362126d657071a doc_id: 833740 cord_uid: i1iznz8a Medical-grade ultrasound devices are now pocket sized and can be easily transported to underserved parts of the world, allowing health care providers to have the tools to optimize diagnoses, inform management plans, and improve patient outcomes in remote locations. Other great advances in technology have recently occurred, such as artificial intelligence applied to mobile health devices and cloud computing, as augmented reality instructions make these devices more user friendly and readily applicable across health care encounters. However, broader awareness of the impact of these mobile health technologies is needed among health care providers, along with training on how to use them in valid and reproducible environments, for accurate diagnosis and treatment. This article provides a summary of a Mayo International Health Program journey to Bwindi, Uganda, with a portable mobile health unit. This article shows how point-of-care ultrasonography and other technologies can benefit remote clinical diagnosis and management in underserved areas around the world. H ow can health care be improved on a global scale in terms of its value to patients, regardless of their health economic status, presence or absence of health insurance, and first-world or thirdworldecountry status? Health care economists propose seeing health care delivery through the lens of the value equation, V ΒΌ Q/C, in which V is value, Q is quality or outcomes, and C is costs. 1 In the United States, the Organization for Economic Cooperation and Development focuses on advancing public health, which is similar to the mission of the National Institutes of Health. In 1948, the World Health Organization defined health as a state of complete physical, mental, and social wellbeing, not merely the absence of disease or infirmity. 2 In 1986, the World Health Organization clarified the definition of health as being a resource for everyday life, not only the objective of living but rather a positive concept, emphasizing social and personal resources as well as physical capacities. [2] [3] [4] The word "resource" appears frequently in the definition of health, which implies that health is composed of resources to deal with physical, mental, and social issues. We sought to use the resources of the Mayo International Health Program (MIHP) to observe and learn about health in underserved parts of the world and witness firsthand the difference in availability of resources in other countries. For this MIHP mission, we were given the opportunity to travel to Bwindi, Uganda, in November 2019. This article focuses on the use of a portable mobile health unit (MHU) with portable ultrasounds 5, 6 as an added relatively low-cost resource for the Bwindi Community Hospital and its potential impact on the global health value equation in terms of diagnostic and management decision making. We report a largely descriptive and retrospective narrative review of a small anonymous case series from an MIHP rotation. The MIHP was started in 2001, by Mayo Clinic, to help broaden experience to underserved areas all over the world. 7, 8 The lead author (C.L.O.) applied to the MHIP program in 2019 and was selected for a mission in November 2019, in Uganda, Africa. The MIHP assigned a 4-week rotation at the Bwindi Community Hospital in November 2019. In keeping with the definition of health as a resource, we brought an MHU to enhance local diagnostic and health care value decision making. The rationale was that this clinic essentially had no advanced technology to help triage patients beyond the physical examination to support decision making regarding selection of patients for referral to higherlevel hospitals in the country. Resources. The MHU comprised 2 portable ultrasound units, donated in-kind by FUJI-FILM Sonosite, Inc (Bothwell, Washington), a digital stethoscope with 1 lead electrocardiogram donated in-kind by Eko Devices Inc. (Oakland, California), compatible with iPhone (Apple Inc., Cupertino, California), and an otoscope with video ( Figure 1 ). After the 4-week rotation, a total of 391 patients had been seen: an average of 17 patients per day. This is a modest number, as the true number of patients seen is higher than 391 when private wards and pediatric patients are included. The Eko Device was used in all patient encounters. Among the patients seen in Bwindi, we performed approximately 46 point-of-care ultrasound (POCUS) examinations in 33 patients during a period of 23 days (approximately 2 examinations per day). Lung, cardiac, optic nerve, vascular, and abdominal ultrasounds were performed according to clinical relevance (Supplemental Figures 1-4 , available online at http:// mcpiqojournal.org). The POCUS examinations took, on average, 10 to 20 minutes, depending on amount of ultrasound clarity and anatomic difficulties. In 15 of the 18 (83.3%) documented cases, use of these bedside diagnostic tools enhanced the formation of diagnoses and thereby positively affected the management and outcomes of these patients. In 4 of the 18 (22.2%), the initial diagnosis was confirmed, and management approach remained unchanged (Table) . To illustrate the clinical decision-making utility of the MHU in Uganda, we are highlighting some specific uses of ultrasound during the rotation. The cases that follow were selected because of their impact on patients, their families, and the team. Case 1: Decompensated Heart Failure With Preserved Ejection Fraction in a Pediatric Patient With Anemia. We performed a cardiac ultrasound examination on a 15-yearold girl with chronic anemia who required multiple blood transfusions. She had a history of chronic kidney disease and probable heart failure. The POCUS examination showed small-to-moderate pericardial effusion, hyperdynamic heart, and suspicion for a thrombus or calcification within the left ventricle. We sent the ultrasound video (without patient identifiers) to a consultant (C.V.B.) in the United States. The initial suspicion was that the finding was an artifact; however, on further review, the determination was made that there was a calcification in the left ventricle attached to the inferoposterior wall (Supplemental Figure 2 , available online at http://mcpiqojournal.org). The patient's abdominal ultrasound showed a cystic mass in the left kidney and right renal agenesis. This developmental malformation caused poor erythropoietin production and likely contributed to her severe anemia and heart failure with preserved ejection fraction (HFpEF). There is no doubt that other contributors, such as malnutrition and possible other genetic malformations, played an important role, as our 15-year-old patient appeared to be only 8 years old. Even though there was no edema on physical examination, she was initiated on furosemide and digoxin to support the need for further blood transfusions. In a 24-hour follow-up POCUS examination, the patient's heart appeared less hyperdynamic, and the ejection fraction was normal (above 50% by Simpson biplane method). Therefore, digoxin was stopped, and later furosemide was also discontinued. Although we were able to obtain a better apical chamber view, it was still challenging to determine whether there was a small thrombus in the left ventricle. Case 2: A Hypertensive Emergency in a Pediatric Patient. A 13-year-old boy presented with systolic blood pressure in the 160s and headache. Review of systems also revealed vomiting and loose stools. The patient was started on captopril and furosemide. With limited resources, a battery of diagnostic tools was ordered. Urinalysis showed 1 red cell cast, red cell smudge, and positive protein. A renal profile was collected. A formal abdominal ultrasound showed mild hydronephrosis, mild portal hypertension, and mild ascites. Because of worsening hypertension (blood pressure, 200s/130s), nifedipine was added to his therapy. The POCUS examination showed ejection fraction 77%, hypertrophic left ventricle, dilated left atrium suggesting diastolic dysfunction, and no pericardial effusion (Supplemental Figure 3 , available online at http://mcpiqojournal.org). At the time, the differential diagnosis was broad and included glomerulonephritis from streptococcus or hepatitis A, focal segmental glomerulosclerosis, minimal change disease, HIV, tuberculosis, lupus erythematosus, aortic dissection, or coarctation of the aorta. Chest radiography was reviewed with a consultant (C.R.) in the United States, who responded as follows: "I don't see a size change in aortic caliber, though it is only anterior-posterior view. There are no additional signs of rib notching or collateralization." On a follow-up POCUS examination, there appeared to be a small pericardial effusion in the subcoastal view, and lung examination revealed B lines, suggesting interstitial fluid in the lung, supporting continuation with current therapy. The local hospital laboratory was unable to perform antistreptolysin O titer or hepatitis A screening because of lack of resources. Over time, his blood pressure improved, but the patient was still complaining of headache and discomfort. Referral to a higher-level facility where further testing was available was discussed with the family; however, they could not afford more testing, and the family took the patient home against medical advice. Case 3: Headache, Weakness, and Hyponatremia. An 80-year-old woman with acute onset of headache and weakness without fever that started 4 days before presentation was brought to the hospital in a wheelchair by her family. She was found to have a sodium level of 122 mEq/L and potassium level of 2 mEq/L. Intravenous fluid with normal saline (0.9%), potassium replacement, and empiric ceftriaxone were started. During our evaluation, she was febrile and hypoxic (oxygen saturation in the 80s) and had accumulation of oral secretion in her mouth. Her neurologic physical examination was as follows: not following commands; Glasgow Coma Scale score of 11 (eyes, 3; verbal, 3; motor, 5); moving all extremities spontaneously but not to commands; upper extremity holding up against gravity but not the lower extremity; normal muscle tone; and sensation intact. Because of her initial presentation of headache, altered mental status, and the new finding of extremity weakness, there was concern of a possible intracranial hemorrhage, which is known to cause hyponatremia. Other differential diagnoses included sepsis and primary hyponatremia from poor diet or recent illness. Following examination, she was initiated on broad-spectrum antibiotics and supplemental oxygen with cardiac monitoring. Transfer to a facility with a critical care unit and computed tomography capabilities were considered, but the transfer never occurred. At bedside, during our POCUS examination, we attempted transcranial Doppler with phased array probe, but the patient had poor skull sonographic windows. The optic nerve sheath measurement demonstrated a left 4.8 mm and right 4.2 mm in diameter, suggesting no increased intracranial pressure. Over the next 2 days, her Glasgow Coma Scale score improved with no focal deficit, and 2 days later she returned to her baseline level and was able to stand with assistance and walk with her cane. Her rapid improvement without specific intervention makes intracranial hemorrhage less likely or, if present, a possible small and stable bleed. Case 4: Unfortunate Case of Respiratory Distress. A pediatric patient was brought to the hospital with symptoms of unresponsiveness and respiratory distress for 3 days. His physical examination revealed Glasgow Coma Scale score of 7 (eyes, 1; verbal, 1; motor, 5), considerable lung crackles, congested breath sounds, poor air entry, and tachypnea. He was given oxygen at 3 L/min via nasal cannula, a blood transfusion, and furosemide (given the previous day). The POCUS revealed a dilated right atrium, likely caused by high chamber pressure, multiple B lines, and a right consolidated lung, but there was no pericardial effusion or pleural effusion. We provided the following recommendations: Optimize supplemental oxygen, administer emergent furosemide and nebulized albuterol, stop intravenous fluids, broaden antibiotics, and perform pulmonary hygiene. The patient had thick airway secretion and was biting the suctioning tube. He did not respond to therapy, and after remaining in the same state for 2 days, with no possibility of transfer to a higher-level facility, he died. Use of Ultrasound for Procedure: Ultrasound-Guided Paracentesis Initially, the providers at Bwindi Community Hospital were performing paracentesis without ultrasound; however, they were interested in learning how to perform abdominal ultrasound for paracentesis and were quick to learn (Supplemental Figure 4 , available online at http://mcpiqojournal.org). Enabling Providers to Work Independently: New Skills in Cardiac, Optic Nerve, and Doppler Ultrasonography By 3 weeks into the rotation, 2 consultants were performing cardiac and optic nerve sheath ultrasound independently. A nurse watched us perform a Doppler ultrasound and was able to perform 1 on his own and acquired the following results in a patient with left-foot gangrene: no artery Doppler signals on the left extremity of the femoral vessels compared with the right, which had good Doppler signals (Video 3, available online at http://mcpiqojournal.org). These findings were confirmed by a trained sonographer and interpreter, who performed the formal ultrasound. Use of this diagnostic tool informed the need for surgical intervention, and the patient ultimately had an above-the-knee amputation rather than medical therapy alone. The MIHP allowed for an incredible experience to enrich medical and procedural knowledge in an underserved region of the world. Bwindi, Uganda was an eye-opening experience, where we noted the luxuries available to us at Mayo Clinic and within US health care: access to a wide range of specialists and subspecialists (surgeons and medical) and services. Advanced and expensive technologiesdintensive care equipment, ventilators, and advanced diagnostics such as computed tomography and magnetic resonance imagingdwere unavailable in Bwindi. Despite this challenge, the MHU concept was deployed successfully, as were aspects of telemedicine from Mayo subspecialists, when available. These findings are critically important and can be reproduced using an interconnected world of health care providers, the internet, and 4G and 5G networks across the globe, especially during the coronavirus disease 2019 (COVID-19) pandemic. Limitations to this report include the retrospective design, limited nature of observations, and selection bias. Yet, we believe that the insights gained from the MIHP experience and the MHU concept can provide tremendous value to rural and other underserved areas worldwide and raise the value of health care using newer, lower-cost technologies such as ultrasound. 9 Moore's law over the past several decades has made it possible for technology to get smaller, faster, and cheaper than ever before, and mobile (smart) phones now run operating systems and have computing power that exceeds the Apollo NASA missions that sent astronauts to the moon decades ago. We believe that local diagnoses and treatment plans may be affected by incorporating the information obtained through bedside ultrasonography and similar small devices as an extension of the physical examination. 10 We acknowledge that the physical examination is the cornerstone to accurate diagnosis in medicine, and the clinicians in Bwindi are masterful in their clinical examination techniques. Our limited MHU data suggest that in approximately 80% of our clinical encounters, supplementation of the history and physical examinations with these added health care technologies resulted in substantially improved diagnostics. Further, there appeared to be educational value in using these technologies in Uganda. 10 Our ability to teach nurses and other physicians how to use these various tools greatly enhanced their standard methods of assessment and diagnostic decision making. Of note, the MHU appeared to be clinically practical for use in remote areas, as it proved to be user friendly and required minimal charging to operate. The Eko DUO digital stethoscope maintains a full battery for weeks; over the 4-week rotation required charging only twice (Supplemental Figure 5 , available online at http://mcpiqojournal.org). All health care workers in the hospital reported high satisfaction working with the Eko Device compared with their standard stethoscope and later became interested in purchasing it. They particularly liked that selected auscultation and electrocardiogram clips could be shared with others for learning and teaching, especially when compared with ultrasound findings in conjunction with classical physical examination findings. In addition, these findings could be deidentified (for patient confidentiality) and viewed multiple times on a smart phone. Many clinicians also saw the value of ultrasound to augment clinical physical examination findings as described here for diagnostic and potential procedural visualization. We acknowledge additional limitations inherent to any technology or tool in health care, with cost being a major one even in 2020. 9 Further, there was concern about the murmur-detection sensitivity of the digital stethoscope, as some users could not hear the murmurs it detected while listening to the patient but were able to hear the murmur during replay or review. Any technology has limits in what it offers the clinician and cannot be the sole factor for all diagnostic and therapeutic decision making. Another limitation and learning experience was that there was often muscle artifact on several electrocardiogram tracings, which may have represented patients' pectoralis muscles in a sitting position vs being recumbent in a supine and relaxed position. This was easy to overcome by adapting the physical examination techniques. We found data filtering for these devices could be improved to limit artifacts. Another limitation to this experience includes lack of formal education and training for the local clinicians in performing ultrasound and using the electrocardiogram and digital stethoscope. However, this may be overcome by organizing a formal training session with a curriculum that can be completed in a few days. 10 Another limitation is the logistics of individuals acquiring their own ultrasounds and the inability to save these clips to review later; our team had to return to the United States with the ultrasound machines and erase (and deidentify) the clips that we brought with us. All of these limitations can be overcome, as ultrasounds are becoming less and less expensive. We therefore hope that this report can help inspire creative philanthropic support and donations to help underserved areas of the world to purchase equipment similar to the MHU. We realize that, despite decreasing costs, budgetary constraints may be prohibitive for many clinics and hospitals; perhaps, over time, the costs will fall to a point at which they can be purchased to add value to local care and expand the scope of MHUs to augment physical examination skills. Although each health care community should evaluate the true value of these technologies in their own context, the technologies we describe appear safe and noninvasive. These can be used in conjunction with augmenting physical examination skills, are relatively simple to operate, and are becoming more widely available to used both for diagnosis and therapeutic purposes. 8, 9 A final visual summary is provided by a "word doodle" composed of comments from nurses and physicians in Uganda about the mobile health tools used in the MIHP experience ( Figure 4) . The value of global health care delivery is changing rapidly and improving over time because of declining costs of MHU technologies. We describe this value through our experience in a community in Uganda. The global COVID-19 pandemic has forced a discussion on how to scale mobile health solutions rapidly at the point of care. Mobile health has emerged as a result of Moore's law, which has allowed smaller, faster, cheaper mobile smart phones, along with emergence of global connectivity via cellular and internet broadband (4G, 5G) communication systems. We changed the initial diagnosis and treatment 80% of the time with our MHU. We were very proud that local providers were performing ultrasounds by themselves by the end of the rotation and that they were very excited to learn more. Pay-for-performance or pay for value? What is good health? The meanings of health and its promotion Tele-ultrasound in resource-limited settings: a systematic review High-resolution image reconstruction for portable ultrasound imaging devices Mayo Clinic College of Medicine and Science. Mayo International Health Program Eight years of the Mayo International Health Program: what an international elective adds to resident education Hospital incidence and outcomes of the acute respiratory distress syndrome using the Kigali modification of the Berlin definition Point-of-care ultrasound use, accuracy, and impact on clinical decision making in Rwanda hospitals We express our sincere thanks to the Mayo Clinic International Health Program (MIHP) and the excellent clinicians of Bwindi, Uganda, for their mentorship: Drs Ben Ochola, Encok Tayebwa, Elias Byamukama, Walufu Ivan Egesa, Balaam, and Holly Tyson, as well as Jackline Maneno, David Niwamanya, Anthony Barugahare, Ruth Tukamushaba, Justus Tukundane, and Agartha Owomugisha. We also acknowledge the in-kind donation for this MIHP mission from Heather Hatch of FUJIFILM Sonosite, Inc., and Steve Avila and Steve Phram of Eko Devices, Inc. Editing, proofreading, and reference verification were provided by Scientific Publications, Mayo Clinic. Supplemental material can be found online at http://mcpiqojournal.org. Supplmental material attached to journal articles has not been edited, and the authors take responsibility for the accuracy of all data.