key: cord-0904547-8a8ndrfn authors: Maestre, Juan P.; Jarma, David; Yu, Jia-Rong F.; Siegel, Jeff; Horner, Sharon; Kinney, Kerry A. title: Distribution of SARS-CoV-2 RNA Signal in a Home with COVID-19 Positive Occupants date: 2021-03-09 journal: Sci Total Environ DOI: 10.1016/j.scitotenv.2021.146201 sha: 8348eeb9058cbc9267577d572215daddde010284 doc_id: 904547 cord_uid: 8a8ndrfn Although many COVID-19 patients isolate and recover at home, the dispersal of SARS-CoV-2 onto surfaces and dust within the home environment remains poorly understood. To investigate the distribution and persistence of SARS-CoV-2 in a home with COVID-19 positive occupants, samples were collected from a household with two confirmed COVID-19 cases (one adult and one child). Home surface swab and dust samples were collected two months after symptom onset (and one month after symptom resolution) in the household. The strength of the SARS-CoV-2 molecular signal in fomites varied as a function of sample location, surface material and cleaning practices. Notably, the SARS-CoV-2 RNA signal was detected at several locations throughout the household although cleaning appears to have attenuated the signal on many surfaces. Of the 24 surfaces sampled, 46% were SARS-CoV-2 positive at the time of sampling. The SARS-CoV-2 concentrations in dust recovered from floor and HVAC filter samples ranged from 104-105 N2 gene copies/g dust. While detection of viral RNA does not imply infectivity, this study confirms that the SARS-CoV-2 RNA signal can be detected at several locations within a COVID-19 isolation home and can persist after symptoms have resolved. In addition, the concentration of SARS-CoV-2 (normalized per unit mass of dust) recovered in home HVAC filters may prove useful for estimating SARS-CoV-2 airborne levels in homes. In this work, using the quantitative filter forensics methodology, we estimated an average integrated airborne SARS-CoV-2 concentration of 69 ± 43 copies/m3. This approach can be used to help building scientists and engineers develop best practices in homes with COVID-19 positive occupants. SARS-CoV-2 transmission inside buildings remains a significant concern as the COVID-19 pandemic continues to surge worldwide. While studies of SARS-CoV-2 contamination in buildings have focused on locations with outbreaks or medical facilities treating critical COVID-19 patients, most individuals with COVID-19 spend their recovery period isolated at home. Reported transmission rates of SARS-CoV-2 in homes are relatively sparse and vary Indeed, experimental studies have verified that a short aerosol release in one room of a house can distribute and eventually settle on surfaces throughout a house (Tang et al., 2020) . While increasing ventilation is one of the major controls available to reduce airborne exposures to SARS-CoV-2 in buildings, this can be difficult to achieve in U.S. households where outdoor air ventilation rates are typically low (Bekö et al., 2016; Shrestha et al., 2019; Yamamoto et al., 2010) . Finally, the temperature and relative humidity in homes can also affect the SARS-CoV-2 virus with longer viabilities and airborne survival times expected at lower temperatures and lower humidity levels (Biryukov et al., 2020; Guillier et al., 2020; Matson et al., 2020) . To our knowledge, SARS-CoV-2 contamination within an isolation household has not been determined directly. However, measurements of SARS-CoV-2 distribution in other environments with COVID-19 occupants (e.g., healthcare facilities, quarantine units and cruise ships) provides insight as to the potential contamination that may be possible Guo et al., 2020; Ong et al., 2020; Santarpia et al., 2020) . In hospitals, for instance, SARS-CoV-2 has been detected on a variety of surfaces (floors, handrails, and soles of medical staff) as well as in short-term air samples collected near patients Guo et al., 2020; Ye et al., 2020) . The evidence suggests that some contaminated surfaces may serve as reservoirs for resuspension Santarpia et al., 2020) and fecal aerosolization of SARS-CoV-2 during flushing of the toilet is another possibility (Elsamadony et al., 2021; Liu et al., 2020; Ma et al., 2020) . In the more confined environment of a commercial cruise ship, Yamagishi et al. (2020) found that 10% of surface samples in case-cabins were SARS-CoV-2 positive but almost no positive detections were observed in common area surfaces or in air samples suggesting limited dispersal. Notably, numerous studies have detected SARS-CoV-2 on the surfaces of J o u r n a l P r e -p r o o f Journal Pre-proof ventilation grates or air outlets in buildings with COVID-19 patients (Guo et al., 2020; Mouchtouri et al., 2020; Nissen et al., 2020; Santarpia et al., 2020) . Recently, the SARS-CoV-2 virus was detected in 25% of the swab samples collected from a heating, ventilation and air conditioning (HVAC) system in one hospital (Horve et al., 2020) , and in 36.8% of vent openings and 89% of HVAC filter dust samples in a COVID-19 ward (Nissen et al., 2020) . The fact that the SARS-CoV-2 virus can be recovered from HVAC filter dust is not too surprising given that previous research has demonstrated that filters from central HVAC systems can serve as longterm spatially integrated samplers of the indoor environment. The filter forensics approach has been used for the assessment of particle-bound contaminants that accumulate in the dust collected on HVAC filters (Bi et al., 2018; Givehchi et al., 2019; Maestre et al., 2018; Noris et al., 2011) including viruses (Goyal et al., 2011; Prussin et al., 2016) . When this approach is combined with HVAC parameters such as flowrate through the filter and usage time, it is possible to quantitatively estimate the time-averaged indoor concentrations of the particle-bound contaminants (Givehchi et al., 2019; Haaland and Siegel, 2017) . This approach has not yet been used to estimate SARS-CoV-2 airborne concentrations but this could be possible if the SARS-CoV-2 concentrations in home HVAC filter dust were known. In addition to investigating the dispersal of SARS-CoV-2 in home environments, the potential for SARS-CoV-2 to persist on materials and dust reservoirs within homes is an important consideration. Fundamental laboratory studies have demonstrated that SARS-CoV-2 can survive on paper for up to 3 hours, treated-wood and other low porosity surfaces for up to 24 hours (Aboubakr et al., 2020; Chin and Poon, 2020) . Other studies have shown longer survivability times up to 28 days (Riddell et al., 2020) at 20°C for high porosity surfaces, such as paper and J o u r n a l P r e -p r o o f Journal Pre-proof banknotes. Furthermore, some viruses such as Influenza A can remain infective upon resuspension from surfaces (Asadi et al., 2020) . Cleaning of contaminated surfaces with disinfectants is expected to mitigate the spread of SARS-CoV-2 in hospitals and other environments including homes (Hirotsu et al., 2020; Kampf et al., 2020; Ong et al., 2020) . Beyond the frequency at which surfaces are sanitized, the effectiveness of cleaning agents vary widely (Sanekata et al., 2010) . Because SARS-CoV-2 is an enveloped virus, surfactants, such as soapy water and other household cleaners, are expected to lyse the viral membrane and eliminate the infectivity of the virus on surfaces (Jahromi et al., 2020) . However, the persistence of SARS-CoV-2 on surfaces is likely affected by the active ingredient in a given cleaner which, for EPA approved cleaners, includes quaternary ammonium salts, sodium hypochlorite, hydrogen peroxide among several others (Sanekata et al., 2010; Tuladhar et al., 2012b) . Investigating SARS-CoV-2 in homes and other built environments is crucial since the spread of SARS-CoV-2 is influenced not only by occupant behavior but also by the characteristics of the buildings themselves. While a substantial number of studies have investigated hospitals, quarantine units, restaurants, and cruise ships, additional research is needed in homes where many COVID-19 patients recover. The objective of this study was to determine the spatial distribution of the SARS-CoV-2 RNA signal in a home one month after two household members recovered from COVID-19. In addition to examining surface samples, we also quantify the viral signal in dust and surface swab samples from the home environment, providing the first J o u r n a l P r e -p r o o f Journal Pre-proof concentration level (N2 gene copy numbers/g dust) for HVAC and floor dust samples for comparison with other built environments. Two members of a family in a home environment study (i.e., a parent (participant 1, P1) and a child (participant 2, P2)) experienced COVID-19 symptoms (CDC, 2020) that were confirmed with a positive COVID-19 test. The two family members remained isolated in their home alone for the following two months. The parent agreed to use a researcher-supplied home sampling kit to obtain samples of the home environment as well as to answer an IRB-approved survey on COVID symptoms and home environment management. All home environment samples were collected by the parent approximately one month after COVID-19 symptoms had resolved in the household (and two months after symptom onset). A total of 22 swab samples were collected from a variety of surfaces across the home as well as from the surface of the HVAC filter. A single phosphate-buffered saline Tween-20 (PBST) wetted swab (Floq Swab, Copan, Murrieta CA) was used to swab each of the surfaces for 20 seconds. When possible, a 929 cm 2 (1ft x1ft) area was swabbed. In other cases, where the sampling area was difficult to estimate (e.g., door handles), the entire available surface was swabbed. For the home HVAC filter, a 32.26 cm 2 area was swabbed. Dust samples were also inch x 20 inch) was vacuumed for one minute. All samples were transported on ice and stored at -20 °C in the laboratory until extraction which occurred within 5 days of sample collection. For total nucleic acids extraction, the MagMAX Total Nucleic Acids extraction kit (ThermoFisher Eugene, Oregon, USA) was used in combination with the KingFisher (ThermoFisher) nucleic acid extractor. At the beginning of sample processing, the dust cake from vacuum samples and the swabs were transferred to the extraction kit bead beating tubes (ThermoFisher) and processed per manufacturer's instructions. The concentration of SARS-CoV-2 in RNA extracts was determined in triplicate on the ViiA7 Real-Time PCR System (ThermoFisher). RT-qPCR utilized the CDC nCOV_N2 primer/probe and CDC nCOV_N1 primer/probe set as well as negative controls (PCR grade water) were used in each RT-qPCR plate. Additionally, negative controls were included in the study and processed concurrently with the samples to J o u r n a l P r e -p r o o f account for background material and reagent contamination. All negative controls indicated no presence of SARS-CoV-2 RNA in the materials or reagents used. The bovine respiratory syncytial virus (BRSV) was utilized to evaluate viral recoveries from each of the matrices (swabs and dust) collected in this study as is done in other environmental studies (Gonzalez et al., 2020) . The reader can find the results from the recovery experiments in section 3.5. Both participants lived full-time in the case study home before the onset of COVID-19 symptoms, during the disease period, and after the recovery period when the samples were collected. The two bedroom 93 m 2 (1,000 ft 2 ) home located in Texas was built between 2008 and 2012, and had a central HVAC system with a Minimum Efficiency Reporting Value (MERV) 4 (fiberglass filament) filter installed. Information regarding COVID-19 symptoms, cleaning practices, and surface materials (Table 1) were gathered via remote survey utilizing the Research Electronic Data Capture (REDCap) platform (Harris et al., 2009) . For surfaces such as carpet and hard flooring, the frequency of vacuum and mopping were also reported. The survey was administered entirely remotely via a survey link sent to the participant's phone, made possible with the REDCap platform. The quantitative filter forensics approach by Haaland and Siegel (2017) was used in this work (Table S2) to estimate the temporally and spatially integrated airborne concentration (C) of J o u r n a l P r e -p r o o f SARS-CoV-2 over the viral collection time period. The following parameters were used for the calculation: m was the mass of dust (g) collected in the HVAC filter, f was the concentration of SARS-CoV-2 (N2 gene copies/g) in the dust collected on the filter, ƞ was the integrated particulate matter filtration efficiency of the MERV-4 filter, Q was the volumetric air flowrate (m 3 /h) through the filter (median for the summer season for the same geographical location, (Givehchi et al., 2019) and t was the runtime of the HVAC system (h) over the duration of the SARS-CoV-2 collection time -approximately one month-, median for the summer season for the same geographical location, (Givehchi et al., 2019) . A few considerations that ought to be taken into account are: (1) our estimate does not account for the attenuation of the signal over time or the losses due to deposition, (2) it considers the estimate that approximately 5.6% of the viral signal is recovered through RNA extraction from the dust matrix (as estimated in this work via the spike and recovery tests for the surrogate BRSV virus), (3) the mass recovered by the participants was estimated to be 68% of that recoverable by trained researcher (based on previous experiments comparing researcher-collected samples to participant-collected samples), and (4) that approximately 27% of the accumulated dust can be recovered from the filter (Mahdavi and Siegel, 2020) . Owing to the use of averaged parameters from a similar population of homes and analysis approaches, our estimate should be considered a scaling approach rather than a precise calculation of SARS-CoV-2 airborne concentration. Also, a full uncertainty analysis was carried out and details can be found in SI. The home was naturally ventilated one hour per day, in the early morning by opening one door. The HVAC temperature setting was kept at 23.9°C (75°F) day and night with the air conditioning system providing cooling during the summer months in this hot and humid region of Texas (average ambient temperature of 35°C (95°F) over the summer months). In our previous study in Texas (Bi et al., 2018) , the average relative humidity in homes during the summer was 56.6% ± 5.2% (n=93, measured over one month). Even though indoor relative humidity varies as a function of temperature, outdoor relative humidity, occupancy and other building factors, this provides us with a reasonable estimate for homes in this study. Regarding the position of the HVAC filter, the low efficiency filter (MERV-4) was positioned vertically in the unit 3 feet above floor height. The HVAC unit was located inside a closet with a louvered door that was normally kept closed. A total of 24 surfaces distributed across six spaces in the home were swabbed on the same day approximately one month after the symptoms of both participants had resolved. A total of 46% of the samples were found to be positive (Table 1, Figure 1 ). In some cases, a specific area was sampled (HVAC filter, counters, floors, and highchair) and the results are reported in N2 gene copies/cm 2 ( Fig. 2A) , whereas in other cases when it was not feasible to normalize by area -or by weight-(e.g., swabbing doorknobs, handles, among others), the results are reported as N2 gene copies recovered per swab (Fig 2B) . In the case of fomites where it was feasible to sample a specific area, the highest number of N2 gene copies/cm 2 were recovered from the filter, whereas the floor in the master bedroom and the J o u r n a l P r e -p r o o f highchair yielded several order magnitude fewer copies/cm 2 . Samples gathered from the bathroom floor, living room floor and second bedroom floor, dinner table and kitchen counter yielded non-detects. In the carpet of the master bedroom, which was used as the primary bedroom by both occupants, a concentration of approximately 20 copies/cm 2 was found. The highchair yielded concentrations one order of magnitude higher than the floor in the master bedroom. Interestingly, a concentration of 4.8 N2 gene copies/cm 2 was measured in the second bedroom (not in use from the onset of symptoms through the sampling event). It is worth noting that vinyl flooring (bathroom and living room), cleaned with Cleaner 1 on a regular basis did not yield any signal, and neither did surfaces that were cleaned with Cleaner 3 such as the kitchen counter and the dinner table. In the case of the results not normalized by area, the highest SARS-CoV-2 RNA signal was observed on the top of the television surface. The vinyl couch as well as the child's toy, the toilet handle, and the doorknob to the master bedroom showed similar viral signal strengths (~100 N2 gene copies recovered per swab). The surfaces in the bathroom did not yield any SARS-CoV-2 signal, except for the toilet handle. The remaining doorknobs (second bedroom and main door) and handles tested, including the kitchen sink handle and refrigerator handle, as well as the cell phone screen, did not yield any signal. Fig. S1 shows all swab samples as recovered copies per swab for direct comparison among all the samples without area normalization. Five methods for cleaning the home environment were used in the home (Table 1 alkyl dimethyl benzyl ammonium chloride) was generally utilized. For doorknobs, Cleaner 1 was utilized once per day. The rest of flooring in both bedrooms was carpeted. The floor in the main bedroom was vacuumed once per day. In the kitchen, Cleaner 3 (active ingredient: sodium laureth sulfate) was employed to clean surfaces such as the counters, the dinner table, as well as the refrigerator and sink handles. In the bathroom, Cleaner 2 was used on all surfaces including the sink, toilet handle and toilet seat. Some portable objects were cleaned with Cleaner 2, including the participant's phone, and the child's toys, cleaned daily and 2-3 times per week respectively. The highchair was cleaned three times per day with water. Other surfaces, such as door trims, the couch, the TV, or the HVAC filter were not cleaned routinely. The highest signal was recovered from the filter, made of fiberglass and never cleaned/disturbed by the participant until the sampling event, followed by the plastic materials (TV top and highchair), and carpet floor. Among the fomites that can be cleaned frequently, those that were vacuumed, not cleaned at all, or cleaned with water only, yielded higher SARS-CoV-2 signal than those cleaned with commercial cleaning products. Another factor that may affect the signal is the cleaning regime (Table 1 , Fig. S2 ) with frequent cleaning of surfaces expected to deplete the signal. The viral signal ranged from 10 5 to 10 6 N2 gene copies/g in the floor dust samples collected via the handheld vacuum (Fig. 4) . The viral signal in the HVAC filter dust ranged from 10 4 to 10 5 copies/g of dust. The concentrations found in the dust from the carpeted master bedroom floor J o u r n a l P r e -p r o o f were significantly higher than those in the HVAC filter dust (Mann-Whitney, p-val<0.001). In both cases, the SARS-CoV-2 signal varied by at least an order of magnitude in the dust samples. As a negative control, vacuum HVAC filter dust samples collected a year prior to the COVID-19 pandemic were also tested and yielded no signal. A subset of positive samples for the N2 assay were tested with the N1 assay to corroborate the results. In each case, all samples yielded positive signals, that were highly correlated (Pearson's product-moment correlation, p-value = 0.002, rho =0.825), although N2 consistently yielded higher copies recovered than N1 ( Figure S4 ). It has been established that microbial RNA/DNA can be lost during the process of extraction (Iker et al., 2013) and by the matrix within which it is embedded (Zuo et al., 2013) . To estimate the effect that matrix can have on viral recoveries (Gonzalez et al., 2020) , the BRSV was used to estimate the viral recovery from swab and dust samples, In this work, when the RNA of a known amount of virus was extracted with no matrix-, approximately 30% of the signal was recovered (Fig. S3 ). When the same quantity of virus was spiked onto a swab (the same kind used in the current study), approximately 25% of the signal was recovered. However, in the case of BRSV spikes into dust samples, a median of approximately 6% was recovered from the filter dust and approximately 8% from the floor dust. As a reference, 7.6% recovery was observed for BRSV in wastewater samples and fungal recoveries from wipe samples have been reported to range from 10% to 25% Gonzalez et al., 2020; Yamamoto et al., 2011) . Similarly, Yang et al. (2011) reported 50% recovery of the virus H1N1 spiked onto PTFE filters while Brown et al. (2020) J o u r n a l P r e -p r o o f could recover between 1% and 10% the foot-and-mouth disease virus in their liquid control with generally lower recoveries reported from surfaces, suggesting non-negligible losses. While it is known that different microorganisms, matrices, surface materials, and virus concentrations (Brown et al., 2020; Fabian et al., 2009; Zuo et al., 2013) can behave differently, the recovery values determined in the present work are within the range reported in other studies of viruses and other microorganisms. Still, the actual recovery of SARS-CoV-2 from many environmental matrices remains largely unknown. isolates at home (Grijalva et al., 2020; Lewis et al., 2020; Wang et al., 2020a; Wu et al., 2020) . In fact, home related outbreaks can be common as evidenced in the study by Qian et al. (2020) where 254 of 318 outbreaks (79.9%) were found to have originated in the home indoor environment. Wang et al. (2020a) found that measures such as home ventilation and frequent cleaning of surfaces were protective against secondary infections. In this work, we detected the SARS-CoV-2 RNA signal (confirmed via N2 and N1 gene assays) across several locations within a home one month after the symptoms of the two COVID-19 positive occupants had subsided. The SARS-CoV-2 signal was found in at least one fomite in every room sampled, including in rooms not in active use. In addition, SARS-CoV-2 was detected in dust from floors and from the HVAC filter installed in the home. We found that 46% of the surfaces had detectable SARS-CoV-2 signal. In other studies , similar detection rates (~40%) were found in rooms with patients in their first week of disease but the rates declined below 20% as the disease progressed. Many factors could have contributed to these observed J o u r n a l P r e -p r o o f differences. In our study, the strength of the viral signal seemed to vary with sample location, fomite surface material, occupant contact level, and cleaning practices. Some of the SARS-CoV-2 positive surfaces, such as HVAC filters, floors, and the top of the TV, are common reservoirs for dust build-up and might be infrequently touched; however, others are high-touch surfaces such as doorknobs, tables and, handles. The viral signals recovered in the current study (median= 966 N2 gene copies recovered per swab sample) were lower than the median value of approximately 3500 N2 gene copies recovered per swab reported in biocontainment and quarantine units (Santarpia et al., 2020) although there was wide variability among sample types. Several relevant factors could explain these differences. First, it is possible that the viral signal in the study house attenuated as time passed after symptoms disappeared whereas the studies in hospitals and quarantine units were normally conducted in or near rooms with active COVID-19 cases. In the quarantine unit study by Santarpia et al. (2020) , the rooms were negatively pressurized with >12 ACH whereas in homes, these ventilation levels are unlikely to be present in air conditioned homes that are closed most of the time. In the present study, the ACH during cooling was not measured although the home was naturally ventilated one hour per day. Finally, the home was cleaned frequently whereas in Santarpia et al. (2020) , the authors mentioned frequent environmental cleaning but many details were not specified (cleaning regime, products), making the comparison difficult. In some cases, the SARS-CoV-2 RNA signal can be normalized by sampling area, which may be a useful metric to compare to other studies. The highest concentrations of N2 gene copies/cm 2 were recovered from the HVAC filter (average 43,000 N2 gene copies/cm 2 ), which was in place J o u r n a l P r e -p r o o f throughout the period of illness and recovery. Other surfaces, such as the floor in the master bedroom and the second room, both carpeted and vacuum-cleaned, and the child's highchair, cleaned with water, yielded signal but at lower concentrations (~5, ~20 and ~125 copies/cm 2 , respectively). Comparing to samples gathered in hospitals, in Feng et al. (2021) 38 copies/cm 2 were found at the patient's bedside wall surface but lower concentrations in the toilet bowl and floor drainage (4 and 2 copies/cm 2 , respectively). In this study, samples gathered from the vinyl bathroom floor and living room floor, both cleaned with Cleaner 1, as well as the dinner table and kitchen counter (cleaned with Cleaner 3), yielded non-detects. It is noteworthy that 4.8 N2 gene copies/cm 2 (nearly 100 N2 gene copies recovered per swab) were recovered in the The static charge and lack of cleaning at this location leads to an accumulation of dust, suggesting that it could be a good reservoir to sample in home environmental studies, as reported elsewhere (Dunn et al., 2013) . Of particular note, the SARS-CoV-2 signal recovered by swabbing the HVAC filter in this study yielded an average viral signal of 38,815 N2 gene copies recovered per swab, higher than those recovered in the biocontainment and quarantine unit study. Horve et al. (2020) found SARS-CoV-2 viral copies in hospital HVAC pre-filters and filters at lower levels (~ 450 cumulative copies across the pre-filters and two filters that were positive). Even though the levels found in the present work are higher, the direct comparison is difficult due to several aspects. First, home and hospital HVAC systems differ in their function; home systems provide greater air recirculation while using generally lower MERV filters than hospitals, whereas in hospital systems, outdoor air is mixed in to provide higher air exchange rates. The second main difference is the total volume of filtered air per surface sampled. Finally, the cumulative time the filters were in use may be different between the two systems. With the available information, we are unable to determine the full influence of these significant factors. Nissen et al. (2020) found viral signal in air vents and filters 50 meters away from patients in a low relative humidity environment (approximately 30%), but they could not detect growth or infectivity, and hypothesized that the virus may have been inactive due to desiccation of the pathogen in the vents. Recent studies have shown a variability in the survivability of the virus in surfaces, depending on the material, temperature, relative humidity, and light, with all of these factors playing an important role (Riddell et al., 2020; Van Doremalen et al., 2020; Wolff et al., 2005) . Whereas one study showed that SARS-CoV-2 survives for up to 7 days in some materials (Aboubakr et al., 2020; Chin and Poon, 2020) , other studies have shown longer survivability times up to 28 days (Riddell et al., 2020) in the dark, at 20 °C and 50% RH. Considering the length of time that J o u r n a l P r e -p r o o f had passed after the participants' symptoms disappeared, the RH average estimate from our previous study in Texas (56.6%  5.2%, (Bi et al., 2018) ), and the temperature setting for the study house (23.9 °C, 75 °F), we hypothesize that the viral signal detected may have been from inactive virus. However, additional studies that address infectivity of SARS-CoV-2 recovered from home surface and dust samples as a function of time, material properties and cleaning practices would be required to address this question. Another factor that may affect the signal recovered from the built environment is the cleaning regime (Fig. S2 ) and the cleaning products used (Table 1, Table S1 ). In the present study, the frequent cleaning of floors and many of the high touch surfaces with cleaning products may explain the low to no signal found on many surfaces. Surfactants from household cleaners can break the viral membrane of the enveloped SARS-CoV-2 virus (Jahromi et al. 2020). For example, all surfaces in the bathroom cleaned regularly with Cleaner 2 (sink handle, toilet seat, and floor) did not yield any SARS-COV-2 signal, except in the case of the toilet handle suggesting that viral shedding in stool could have happened. Studies have found SARS-CoV-2 presence in stool samples up to 28 days after hospital admission (Xu et al., 2020) , 6-10 days after negative nasopharyngeal swabs (Chen et al., 2020b) . However, it is important to recognize that the viral signal detected in the toilet handle could also have settled there via transport from another area of the home. The persistence of the SARS-CoV-2 RNA signal on surfaces likely varies widely due to the active ingredient within the cleaner used. Quaternary ammonium, a compound found in Cleaner 2 in this study as well as in a majority of EPA recommended cleaners, has been shown to be effective against viruses (Shirai et al., 2000; J o u r n a l P r e -p r o o f 2012a) such as the enveloped murine norovirus (MNV-1) and feline calicivirus (FCV) (Kennedy et al. 1995) . Ma et al. (2020) found that COVID-19 positive patients in early stages had breath emission rates estimated to range from 1.03x10 5 to 2.25x10 7 viruses per hour. It is likely that the concentrations would be lower towards the end of the recovery period as reported in sputum samples elsewhere (Wölfel et al., 2020) . Taking into account the two COVID-19 positive dwellers, the length of their quarantine and ventilation mode (a door opened during one hour per day plus infiltration), it is reasonable that viral particles accumulated in the case study home. In this study, viral signals were recovered from the dust from both the main bedroom floor and the HVAC filter. Even though the floors of the study home were vacuumed frequently, the viral signal in the carpeted floor from the master bedroom was above 10 5 N2 gene copies/ gram of dust, suggesting that the viral signal may be difficult to remove just by vacuuming. As indicated in Staudt et al. (2020) , the highest viral loads can be found on floors and airborne aerosols can be formed from resuspension of settled dust or aerosols. In the present work, the signal found in the HVAC filter dust was an order of magnitude lower than that recovered from the floors. In both cases, the viral concentration in each dust sample type varied by at least an order of magnitude indicating that replicate analyses are needed to represent the heterogeneity of the dust. Solely for context, having not found other works providing SARS-COV-2 concentrations per gram of dust, the concentrations measured in this work are on the same order of magnitude or even higher than those found in stool from COVID-19 positive patients at the peak of their symptoms (Wölfel et al., 2020) but lower than those found in other cases (Lescure et al., 2020) . The virus is not expelled naked but attached to larger respiratory fluid particles, forming both large and small droplets (aerosols) that can be involved in transmission (Prather et al., 2020) . Filters can remove airborne viruses and particles to which viruses have attached, but their efficiency varies significantly. Low MERV filters are not very efficient at removing smaller particles with, for example, filters rated MERV 5 and below are reported to remove less than 25% of particles smaller than 10 µm (Azimi et al., 2014) . As a result, only a fraction of viral aerosols may be retained in the filter in a single pass although our results suggest removal and accumulation can occur over time. It is worth noting that the filter used in this study was very low efficiency and likely only captured larger particles. Mahdavi and Siegel (2020) found that the volume median diameter of particles on MERV 8-14 filters in residences were 23.4 to 75.1 µm and we expect an even larger median particle size on this filter because of its lower efficiency. These very large particles are predominantly dust particles (often originating from resuspension from floors) and this leads to two potential hypotheses: the viral RNA in the filter samples originated from RNA attached to floor dust that became airborne and/or smaller particles containing viral RNA deposited on the dust on the filter, particularly as the filter became loaded. Given the low efficiency of these filters, even when loaded, we believe that the first hypothesis is likely the dominant factor. We want to emphasize that this RNA may simply represent fragments of viral RNA present on the filter dust that are not infective given the sampling timeframe and the environmental stresses encountered in HVAC filters. Nissen et al. (2020) found viral signal in air vents and filters 50 meters away from patients in a low relative humidity environment (approximately 30%), but they could not detect growth or infectivity, and hypothesized that the virus may have been inactive due to desiccation of the pathogen in the vents. It is also notable that we found a strong viral signal in the HVAC filter dust, located inside J o u r n a l P r e -p r o o f a closet with a closed louvered door. This indicates the viral-laden particles were at some point airborne (either after being expelled or after being resuspended). Low efficiency filters, frequently used because of their low cost, primarily act as a 'roughing filter', removing large particulate matter to protect the HVAC system. In order to enhance capture of viral-laden particles in a home (and potentially diminish the redistribution of viruses across the home), high MERV filters could be used. This work indicates that it is possible to detect the previous presence of a viral shedding individual in the built environment via HVAC filter forensics and suggest this approach may be useful for SARS-CoV-2 monitoring in home environments. In addition, using the QFF methodology (Haaland and Siegel, 2017) , we estimated an average integrated airborne SARS-CoV-2 concentration of 69 ± 43 copies/m 3 (see Table S2 for more details). This value can serve for future comparisons of concentrations of SARS-CoV-2 in the built environment and help building scientists and engineers as they strive to develop best practices in homes with COVID-19 positive occupants. Studies of the viral signal decay and infectivity in HVAC filter dust are warranted to further determine the usability and limits of this approach, and future work should include direct measurements of HVAC and extraction parameters to better characterize the integrated SARS-CoV-2 concentrations. Because HVAC filter dust represents a pooled sample, contributed to by all occupants in a building over an extended period of time, repeated monitoring could be used to identify spikes in measured viral concentrations in the dust. These spikes could indicate new or active infections and be used to guide additional isolation or ventilation practices to minimize the spread of the virus. J o u r n a l P r e -p r o o f Journal Pre-proof As the body of literature increases, it seems clear that in order to diminish viral loads and decrease the probablity of in-home secondary transmission in the built environment, efficient ventilation, high-efficiency filtration and frequent cleaning are important (Allen and Marr, 2020). While detection of viral RNA does not imply infectivity, this study confirms that the SARS-CoV-2 RNA signal can persist in a COVID-19 household for nearly a month following resolution of COVID-19 symptoms. In addition, several factors that may affect the distribution of SARS-CoV-2 across a home have been identified. The results indicate that cleaning can greatly reduce or eliminate the SARS-CoV-2 signal on surfaces. Also, even a low efficiency home filter is capable of capturing and retaining SARS-CoV-2. The detection of the SARS-CoV-2 RNA signal on infrequently touched surfaces may indicate that airborne particles settle out of the air, potentially contaminating surfaces not in direct contact with COVID-19 positive individuals. As the COVID-19 pandemic continues, the SARS-CoV-2 transmission pathways continue to be widely debated. Homes are essential environments that warrant further study to better understand SARS-CoV-2 aerosols and fomites in the home environment where many COVID-19 individuals recover. This study has several limitations. First, the distribution of the SARS-CoV-2 RNA signal across a single household was investigated at one time point two months after COVID-19 symptom onset. Additional isolation homes during and after COVID-19 infections should be studied to determine the temporal course of SARS-CoV-2 distribution within homes as well as to investigate how different household factors affect this distribution across a wide variety of home J o u r n a l P r e -p r o o f types. Second, viral culturing was not performed to determine virus viability/infectivity; thus, this work only reports SARS-CoV-2 viral signal found independently of its viability. Future studies are needed to establish whether there are infective viruses in samples obtained from home environments. Finally, the current study is based on the recovery of SARS-CoV-2 RNA from a range of sample types. It is well established that recovery of RNA from environmental samples is often attenuated by losses during the extraction process or retention within the sample matrix. Thus, future studies are warranted to investigate these effects as the recovery of SARS-CoV-2 from many complex sample matrices such as dust have not been established. • SARS-CoV-2 RNA signal detectable in dust and on surfaces in a COVID-19 quarantine home. • Molecular results indicate SARS-CoV-2 RNA signal can accumulate in a home HVAC filter and cleaning removes SARS-CoV-2 signal from surfaces. • Measurements of SARS-CoV-2 concentration in home HVAC filter dust provide first estimate of average indoor airborne concentrations using Quantitative Filter Forensics. Assessment and mitigation of aerosol airborne SARS-CoV-2 transmission in laboratory and office environments Estimates of HVAC filtration efficiency for fine and ultrafine particles of outdoor origin Diurnal and seasonal variation in air exchange rates and interzonal airflows measured by active and passive tracer gas in homes Phthalates and organophosphates in settled dust and HVAC filter dust of U.S. low-income homes: Association with season, building characteristics, and childhood asthma Increasing temperature and relative humidity accelerates inactivation of SARS-CoV-2 on surfaces Environmental and air sampling are efficient methods for the detection and quantification of foot-and-mouth disease virus Short-range airborne route dominates exposure of respiratory infection during close contact The presence of SARS-CoV-2 RNA in the feces of COVID-19 patients Detection of air and surface contamination by SARS-CoV-2 in hospital rooms of infected patients Stability of SARS-CoV-2 in different environmental conditions-Authors' reply Home life: factors structuring the bacterial diversity found within and between homes Possible transmission of viruses from contaminated human feces and sewage: Implications for SARS-CoV-2 An optimized method to detect influenza virus and human rhinovirus from exhaled breath and the airborne environment Multi-route transmission potential of SARS-CoV-2 in healthcare facilities Quantitative filter forensics with residential HVAC filters to assess indoor concentrations COVID-19 surveillance in Southeastern Virginia using wastewater-based epidemiology Detection of viruses in used ventilation filters from two large public buildings Transmission of SARS-COV-2 Infections in Households -Tennessee and Wisconsin. MMWR Morb Mortal Wkly Rep Modeling the inactivation of viruses from the coronaviridae family in response to temperature and relative humidity in suspensions or on surfaces Aerosol and Surface Distribution of Severe Acute Respiratory Syndrome Coronavirus 2 in Hospital Wards Quantitative filter forensics for indoor particle sampling Research electronic data capture (REDCap)-A metadata-driven methodology and workflow process for providing translational research informatics support Environmental cleaning is effective for the eradication of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in contaminated hospital rooms: A patient from the Diamond Princess cruise ship Identification of SARS-CoV-2 RNA in Healthcare Heating, Ventilation, and Air Conditioning Units Evaluation of commercial kits for the extraction and purification of viral nucleic acids from environmental and fecal samples Persistence of coronaviruses on inanimate surfaces and their inactivation with biocidal agents Clinical and virological data of the first cases of COVID-19 in Europe: a case series Household Transmission of SARS-CoV-2 in the United States The characteristics of household transmission of COVID-19 Repeated COVID-19 relapse during post-discharge surveillance with viral shedding lasting for 67 days in a recovered patient infected with SARS-CoV-2 Transmission dynamics of COVID-19 outbreaks associated with child care facilities US CDC real-time reverse transcription PCR panel for detection of severe acute respiratory syndrome coronavirus 2 COVID-19 patients in earlier stages exhaled millions of SARS-CoV-2 per hour Household transmission of SARS-CoV-2: a systematic review and meta-analysis of secondary attack rate Filter forensics: microbiota recovery from residential HVAC filters Extraction of Dust Collected in HVAC Filters for Quantitative Filter Forensics Effect of environmental conditions on SARS-CoV-2 stability in human nasal mucus and sputum Transmission of SARS-CoV-2 by inhalation of respiratory aerosol in the Skagit Valley Chorale superspreading event Airborne transmission of SARS-CoV-2: The world should face the reality Environmental contamination of SARS-CoV-2 on surfaces, air-conditioner and ventilation systems Long-distance airborne dispersal of SARS-CoV-2 in COVID-19 wards Evaluation of HVAC filters as a sampling mechanism for indoor microbial communities Surface Environmental, and Personal Protective Equipment Contamination by Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) from a Symptomatic Patient Viral load of SARS-CoV-2 in clinical samples Airborne transmission of SARS-CoV-2 Seasonal dynamics of the airborne bacterial community and selected viruses in a children's daycare center Indoor transmission of SARS-CoV-2 The effect of temperature on persistence of SARS-CoV-2 on common surfaces Evaluation of the antiviral activity of chlorine dioxide and sodium hypochlorite against feline calicivirus, human J o u r n a l P r e -p r o o f influenza virus, measles virus, canine distemper virus, human herpesvirus, human adenovirus, canine adenovirus and canine parvovirus Aerosol and surface contamination of SARS-CoV-2 observed in quarantine and isolation care Effects of chlorine, iodine, and quaternary ammonium compound disinfectants on several exotic disease viruses Impact of Low-Income Home Energy-Efficiency Retrofits on Building Air Tightness and Healthy Home Indicators Airborne Transmission of SARS-CoV-2: Proceedings of a Workshop-in Brief Transport of indoor aerosols to hidden interior spaces Temporal profiles of viral load in posterior oropharyngeal saliva samples and serum antibody responses during infection by SARS-CoV-2: an observational cohort study. The Lancet Infectious Diseases Different virucidal activities of hyperbranched quaternary ammonium coatings on poliovirus and influenza virus Virucidal efficacy of hydrogen peroxide vapour disinfection Aerosol and surface stability of SARS-CoV-2 as compared with SARS-CoV-1 Reduction of secondary transmission of SARS-CoV-2 in households by face mask use, disinfection and social distancing: a cohort study in Beijing, China Household transmission of SARS-CoV-2 Virological assessment of hospitalized patients with COVID-2019 Environmental survival and microbicide inactivation of coronaviruses. Coronaviruses with special emphasis on first insights concerning SARS Household Transmission of SARS-CoV-2 Characteristics of pediatric SARS-CoV-2 infection and potential evidence for persistent fecal viral shedding Environmental sampling for severe acute respiratory syndrome coronavirus 2 during a COVID-19 outbreak on the diamond princess cruise ship Residential air exchange rates in three major US metropolitan areas: results from the Relationship Among Indoor, Outdoor, and Personal Air Study Concentrations and size distributions of airborne influenza A viruses measured indoors at a health centre, a day-care centre and on aeroplanes Environmental contamination of SARS-CoV-2 in healthcare premises Comparison of spike and aerosol challenge tests for the recovery of viable influenza virus from non-woven fabrics Maestre: Conceptualization, methodology, analysis, investigation, visualisation, and writing and manuscript review Methodology, investigation, visualisation, and writing and manuscript review Cesca Yu: Literature review Analysis, resources, manuscript review Sharon Horner: Supervision, resources, writing, and manuscript review Supervision, resources, analysis, writing and manuscript review ☒ The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.☐The authors declare the following financial interests/personal relationships which may be considered as potential competing interests: J o u r n a l P r e -p r o o f Table S1 for active ingredient J o u r n a l P r e -p r o o f