key: cord-0919626-auywm29c authors: Audigé, Annette; Böni, Jürg; Schreiber, Peter W.; Scheier, Thomas; Buonomano, Roberto; Rudiger, Alain; Braun, Dominique L.; Eich, Gerhard; Keller, Dagmar I.; Hasse, Barbara; Berger, Christoph; Günthard, Huldrych F.; Manrique, Amapola; Trkola, Alexandra; Huber, Michael title: Reduced Relative Sensitivity of the Elecsys SARS-CoV-2 Antigen Assay in Saliva Compared to Nasopharyngeal Swabs date: 2021-08-10 journal: Microorganisms DOI: 10.3390/microorganisms9081700 sha: 23467487cb1238e25f30d41bef18f112b288112a doc_id: 919626 cord_uid: auywm29c Early identification and isolation of SARS-CoV-2-infected individuals is central to contain the COVID-19 pandemic. Nasopharyngeal swabs (NPS) serve as a specimen for detection by RT-PCR and rapid antigen screening tests. Saliva has been confirmed as a reliable alternative specimen for RT-PCR and has been shown to be valuable for diagnosing children and in repetitive mass testing due to its non-invasive collection. Combining the advantages of saliva with those of antigen tests would be highly attractive to further increase test capacities. Here, we evaluated the performance of the Elecsys SARS-CoV-2 Antigen assay (Roche) in RT-PCR-positive paired NPS and saliva samples (N = 87) and unpaired NPS (N = 100) with confirmed SARS-CoV-2 infection (Roche cobas SARS-CoV-2 IVD test). We observed a high positive percent agreement (PPA) of the antigen assay with RT-PCR in NPS, reaching 87.2% across the entire cohort, whereas the overall PPA for saliva was insufficient (40.2%). At Ct values ≤ 28, PPA were 100% and 91.2% for NPS and saliva, respectively. At lower viral loads, the sensitivity loss of the antigen assay in saliva was striking. At Ct values ≤ 35, the PPA for NPS remained satisfactory (91.5%), whereas the PPA for saliva dropped to 46.6%. In conclusion, saliva cannot be recommended as a reliable alternative to NPS for testing with the Elecsys Anti-SARS-CoV-2 Antigen assay. As saliva is successfully used broadly in combination with RT-PCR testing, it is critical to create awareness that suitability for RT-PCR cannot be translated to implementation in antigen assays without thorough evaluation of each individual test system. Severe Acute Respiratory Syndrome Coronavirus-2 (SARS-CoV-2) infection is routinely diagnosed by reverse-transcription polymerase chain reaction (RT-PCR) in nasopharyngeal swabs (NPS). In early infection, NPS are considered the optimal material for detection [1] . However, NPS collection requires trained personnel, exposes the personnel Probed specimen were leftover from routine diagnostics and a previous study [21] approved with an ethics waiver by the Zurich Cantonal Ethics Commission (Req-2020-00398). No additional personal data beyond the usual information on symptoms and duration required by the Swiss Federal Office of Public Health for all SARS-CoV-2 tests in Switzerland were collected. For nasopharyngeal sampling, conventional swab and virus transport medium (VTM)/universal transport medium (UTM) were used. Transport media included in-house VTM (HEPES, DMEM, FCS, antibiotics, antimycotics) and Virus Preservative Medium (Improviral) for paired PCR-positive NPS; Liquid amies preservation medium (Copan) for unpaired PCR-positive NPS; in-house VTM for paired PCR-negative NPS. Saliva collection was conducted as previously described [21] . Briefly, individuals were asked to clear the throat thoroughly and collect saliva up to three times into an empty saliva collection tube to collect 0.5-1 mL (approx. a teaspoon full). Immediately after saliva collection, VTM was added to the crude saliva and the content mixed through gentle tilting. Saliva was collected directly after NPS for paired analysis and both specimens were immediately sent for SARS-CoV-2 RT-PCR testing. Residual material was stored at −80 • C until use in the present study. RT-PCR tested (Roche cobas SARS-CoV-2 IVD test), cryo-preserved (−80 • C) NPS and saliva specimens were included. Paired SARS-CoV-2 NPS and saliva included positive (N = 87) and negative tested samples (N = 220) collected in the framework of a prior study that conducted a prospective head-to-head comparison of the specimen by RT-PCR [21] . In addition, SARS-CoV-2 positive NPS samples from routine diagnostic testing were included (N = 100). NPS and saliva were processed identically using the procedures established for NPS in the diagnostics laboratory of the Institute of Medical Virology, University of Zurich. A total of 500 µL of NPS or saliva in VTM were diluted in 500 µL of Nuclisens easyMAG Lysis Buffer (bioMérieux, Marcy-l'Étoile, France), centrifuged (2000 rpm, 5 min), and analyzed with the cobas SARS-CoV-2 IVD test (Roche, Basel, Switzerland) on a Cobas 6800. RT-PCR testing for paired NPS and saliva was done in parallel on the same day as part of a previously published study [21] . SARS-CoV-2 detection was further quantified using SARS-CoV-2 Frankfurt 1 RNA as a calibrator (European Virus Archive, 004N-02005) allowing to report both Ct and genome equivalents. E-gene Ct values were used for comparison. In one NPS sample, the E-gene Ct value was considerably higher than the ORF1-gene Ct value (37.31 vs. 26.8) ; in this case, the ORF1-gene Ct value was used for the analysis. Samples were thawed at room temperature and analyzed with the Elecsys SARS-CoV-2 Antigen assay (Roche, Basel, Switzerland) on a cobas e 411 analyzer (Roche, Basel, Switzerland) according to the manufacturer's instructions. Briefly, Elecsys SARS-CoV-2 Antigen is an electrochemiluminescence immunoassay, which detects the nucleocapsid (N) antigen of SARS-CoV-2. The assay uses an antibody sandwich principle. Results are recorded as the Cutoff Index (COI). Saliva samples were treated identically to NPS. Single measurements were conducted. Positive Percent Agreement (PPA), Negative Percent Agreement (NPA), and Overall Percent Agreement (OPA) between the Elecsys Anti-SARS-CoV-2 Antigen assay and the cobas SARS-CoV-2 IVD test were calculated. PPA was determined and stratified by Ct values (PPAoverall and PPA < Ct). PPA, NPA, and OPA were calculated using R (version 4.0.2); 95% confidence intervals (CI, two-sided) were calculated with the epiR package (version 1.0.15). Analysis of correlation (Spearman correlation) between the E-gene Ct value and antigen assay Cutoff Index (COI) and linear regression analysis were performed with GraphPad Prism (version 8.4.3) . p values < 0.05 were considered statistically significant. All raw data are available in Supplemental Table S1 . The Elecsys SARS-CoV-2 Antigen assay has been established for the detection of SARS-CoV-2 in nasopharyngeal and oropharyngeal swab samples from patients with signs and symptoms suggestive of COVID-19 or known or suspected exposure to SARS-CoV-2 (Elecsys SARS-CoV-2 Antigen Assay Method sheet v1 (December 2020)). Here, we probed its capacity in detecting SARS-CoV-2 in saliva by comparing the performance in specimens previously tested by RT-PCR (cobas SARS-CoV-2 IVD). PCR-positive samples included paired NPS-saliva samples (N = 87) and unpaired NPS samples (N = 100). PCR-negative samples comprised paired NPS-saliva samples (N = 220). Symptomatic and asymptomatic donors were included (Table 1) . We first established the positive percent agreement (PPA) of the Elecsys Anti-SARS-CoV-2 Antigen assay using NPS or saliva with the cobas SARS-CoV-2 IVD test. The overall PPA for NPS (including paired and unpaired NPS; N = 187) was 87.2%, with 100% PPA for samples with Ct values ≤ 28 and respectable 91.5% PPA for samples with Ct values ≤ 35 (Table 2 ). In the paired NPS-saliva cohort (N = 87), these values were similar for NPS, reaching PPAoverall = 86.2%, PPA