key: cord-0921996-q1tpybia authors: Huang, Yi; Xiao, Shuqi; Yuan, Zhiming title: Comparison and Evaluation of Real-Time Taqman PCR for Detection and Quantification of Ebolavirus date: 2021-08-10 journal: Viruses DOI: 10.3390/v13081575 sha: 257f32024dd921f9cb426d4c5d8a7cbc27af91f8 doc_id: 921996 cord_uid: q1tpybia Given that ebolavirus causes severe and frequently lethal disease, its rapid and accurate detection using available and validated methods is essential for controlling infection. Real-time reverse-transcription PCR (RT-PCR) has proven to be an invaluable tool for ebolaviruses diagnostics. Many assays with different targets have been developed, but they have not been externally compared or validated, and limits of detection are not uniformly reported. Here we compared and evaluated the sensitivity, reproducibility and specificity of 23 in-house assays under the same conditions. Our results showed that these assays were highly gene- and species- specific when evaluated using in vitro RNA transcripts and viral RNA, and the potential limits of detection were uniformly reported ranging from 10(2) to 10(6) in vitro synthesized RNA transcripts copies perμL and 1–100 TCID(50)/mL. The comparison of these assays indicated that those targeting the more conservative NP gene could be the better option for EVD case definition and quantitative measurement because of its higher sensitivity for the same species. Our analysis could contribute to the standardization of ebolavirus detection and quantification assays, which can offer a better understanding of the meaning of results across laboratories and time points, as well as make them easy to implement, especially under outbreak conditions. The Ebolavirus genus falls within the Filoviridae family and Mononegavirales order, and it constitutes enveloped, non-segmented and negative-polarity RNA viruses [1] . Six distinct species have been identified in the Ebolavirus genus (ebolaviruses): Zaire ebolavirus (Ebola virus, EBOV), Sudan ebolavirus (Sudan virus, SUDV), Reston ebolavirus (Reston virus, RESTV), Taï Forest ebolavirus (Taï Forest virus, TAFV), Bundibugyo ebolavirus (Bundibugyo virus, BDBV) and Bombali ebolavirus (Bombali virus, BOMV) [2, 3] . EBOV has been responsible for the most epidemics, for example, Makona, one of its recognized variants, was the causative agent in the 2014-2016 West Africa epidemic which affected approximately 30,000 individuals and claimed over 11,000 lives [4] . Prior to this epidemic, 13 outbreaks with a total of 1460 cases of EBOV infections were documented following its discovery in 1976 [5] . The most recent outbreak in the Democratic Republic of Congo, which is ongoing at the time of writing [6] , has claimed more than 3000 lives and is the largest EBOV outbreak in the nation's history. A new EBOV variant has been implicated as the cause of the outbreak with the proposed name "Tumba" [7] . Ebola virus disease (EVD) is a lethal viral hemorrhagic fever caused by ebolavirus and has a case fatality rate ranging from 25% to 90%. Clinically, EVD patients have non-specific flu-like symptoms along with hemorrhagic complications and multiple organ failure, which usually appear in the late stage of the disease. EVD symptoms usually include sudden onset of fever, muscle pain, headache and sore throat, followed by vomiting, diarrhea, rash and both internal and external bleeding (e.g., blood in stools and bleeding from the gums) [1] . The incubation period of EVD in humans varies, symptoms characteristically begin from viral RNA transcripts. EBOV specific assays were also evaluated using viral RNAs extracted from cell-culture-propagated viruses, confirming that they are gene-and species specific. Thus far, only a few papers have been published that are directly related to comprehensive validation and comparison of these assays as a diagnostic tool. A literature review was carried out to collect 23 real time RT-PCR assays for ebolaviruses detection ( Table 1 ). The regions of NP, GP and VP40 are targeted for primers and probes. 6-carboxy-fluorescein (FAM) was the fluorescent reporter dye that covalently linked to its 5 end. Furthermore, the quencher dye was Black Hole Quencher ® -1(BHQ1) covalently attached to its 3 end. All primers and probes were synthesized by AUGCT Biotechnology (Wuhan, China). Ebolaviruses Mayinga and Makona variant are provided by National Biosafety Laboratory, Chinese Academy of Sciences. The Vero E6 cell line and 293T cell line was obtained from the Preservation Center in Wuhan Institute of Virology, Chinese Academy of Sciences. Virus stocks were propagated in Vero E6 cells, and infectious titers determined by 50% tissue culture infectious dose assay. All work with infectious Ebola viruses were performed in BSL-4 facility of National Biosafety Laboratory in Wuhan, China, which had been certified by the China National Accreditation Service for Conformity Assessment (CNAS) and the National Health and Family Planning Commission of China [37] . Cells (293T) were transfected with recombinant pCMV-C-His containing ebolaviruses NP, GP and VP40 gene using Lipofectamine 2000 (Invitrogen, Carlsbad, CA, USA) according to the manufacturer's instructions. Viruses were titrated by TCID 50 on Vero E6 cells. Briefly, 96-well plates containing Vero E6 cells were incubated for 1 h at 37 • C in a 5% CO 2 incubator with 0.1 mL of serial dilutions of virus stocks using 1:10 as the starting dilution. Add 100 uL of 2% FBS medium in each well. After incubation for 5-7 days at 37 • C in 5% CO 2 , CPE was observed and calculate the TCID 50 /mL. Viral RNA was extracted from 140 µL of supernatant from virus-infected Vero cells using the RNA extraction kit (QIAamp Viral RNA Mini Kit, Qiagen Inc., Valencia, CA, USA) following the manufacturer's instructions. The extracts were resuspended in 60 µL of Buffer AVE, aliquoted and stored at −70 • C before RT-PCR amplification was carried out. Total RNAs from transfected 293T cells were isolated using E.Z.N.A. TM Total RNA Kit I (Omega Bio-tek, Norcross, GA, USA) according to the manufacturer's instructions as mimic viral RNA for specificity evaluation of assays. The ebolaviruses in vitro RNA transcripts were synthesized using the T7 RiboMAX TM expression large-scale RNA production system (Promega, Madison, WI, USA) according to the manufacturer's instructions. Briefly, the high-quality DNA templates (plasmid containing the target gene including NP, GP or VP40 of different Ebola virus species) were linearized by restriction enzyme (TaKaRa Bio, Shiga, Japan) and then purified by E.Z.N.A.TM Cycle-Pure Kit (Omega). The in vitro transcription reactions were carried out 30 min at 37 • C with 2 µg DNA. Two units of RQ1 RNase-free DNase (Promega) were then added and incubation was continued for a further 60 min. The reactions were incubated for 15 min at 70 • C to inactivate the DNase. The transcripts were extracted using an E.Z.N.A. TM MicroElute RNA Clean-up Kit (Omega) and resuspended in 50 µL of DEPC-treated water. The concentration of RNA transcript was determined by NanoDrop 2000 Spectrophotometer (Thermo Scientific, Wilmington, DE, USA). RNA transcripts were stored at −70 • C throughout this study. The primers and probes used in these assays were listed in Table 1 . One-step Realtime quantified RT-PCR assays were optimized using AgPath-IDTM One-step RT-PCR Kit (Applied Biosystems, Carlsbad, CA, USA). According to the user guide, each reaction contained 12.5 µL 2xRT-PCR Buffer, 1 µL Forward primer (10 µM), 1 µL Reverse primer (10 µM), 0.3 µL TaqMan probe (10 µM), 1 µL 25xRT-PCR Enzyme Mix, 0.05 µL RNase Inhibitor (40 U/µL, Beyotime, Shanghai, China), 7.15 µL Nuclease-free Water and 2 µL RNA. In place of sample, the extraction from non-infected cell culture supernatant and Nucleasefree Water was utilized as negative control. One-step Real-time qRT-PCR amplification was performed on a Bio-Rad CFX96 system. The procedure was as follow: reverse transcription at 4 • C for 10 min, RT initial denaturation at 95 • C for 10 min, 40 cycles of amplification at 95 • C for 15 s and annealing/extension at 60 • C for 45 s. The sensitivity of real-time RT-PCR ebolaviruses specific assays was evaluated firstly using in vitro RNA transcripts, each containing one of the ebolaviruses NP, GP and VP40 coding sequences (CDS). The quality of the RNA standards synthesized by the in vitro T7 RNA transcription system was good enough for real-time RT-PCR assays because the ratios of absorbance at 260 and 280 nm (A 260 /A 280 ) were between 2.0 and 2.1 (indicating high purity), and the concentrations of the RNA transcripts ranged from 1 to 7 mg/µL. RNA copy numbers were calculated according to the concentration and molecular weight of each single-stranded RNA fragment. The threshold cycle (Ct) values were calculated from the various amplification plots of the range of dilutions and used to draw a standard curve which could easily be used for an absolute quantitative analysis of unknown samples (Table 2 and Table S1 , Supplementary Materials). Table 2 . The standard curves and detection limits of TaqMan RT-PCR assays for different ebolavirus species. Amplification plots were realized on 10-fold dilutions of known concentration of transcript RNAs containing the CDS of NP, GP or VP40 from each species of ebolavirus. From the obtained standard curves, the sensitivity for each assay was also determined. (x stand for Log copies/µL and y stand for Ct value). ZENP-H y = −3.3488x + 40.203 R 2 = 1 10 1 RNA copies/µL ZENP-W y = −3.1843x + 38.867 R 2 = 1 10 0 RNA copies/µL ZENP-Y y = −3.4368x + 41.094 R 2 = 1 10 1 RNA copies/µL ZENP-P y = −3.6168x + 42.187 R 2 = 1 10 1 RNA copies/µL ZENP-L Y = −3.4958x + 41.038 R 2 = 1 10 1 RNA copies/µL ZSENP-Z y = −3.2535x + 40.697 R 2 = 1 10 1 RNA copies/µL (EBOV) ZEGP-T y = −3.6921x + 46.095 R 2 = 1 10 2 RNA copies/µL ZEGP-R y = −3.3082x + 47.782 R 2 = 1 10 3 RNA copies/µL ZEGP-G y = −3.2236x + 45.698 R 2 = 1 10 2 RNA copies/µL ZEGP-L y = −3.3500x + 46.64 R 2 = 1 10 2 RNA copies/µL ZEVP40-R y = −3.7963x + 52.524 R 2 = 1 10 4 RNA copies/µL SENP-T04 y = −3.5607x + 55.573 R 2 = 1 10 5 RNA copies/µL SENP-T08 y = −3.4582x + 54.547 R 2 = 1 10 5 RNA copies/µL SENP-P y = −3.4264x + 54.151 R 2 = 1 10 5 RNA copies/µL SENP-W y = −3.4850x + 54.82 R 2 = 1 10 5 RNA copies/µL ZSENP-Z y = −3.4364x + 55.501 R 2 = 1 10 5 RNA copies/µL (SUDV) SEGP-T y = −3.1054x + 52.319 R 2 = 1 10 4 RNA copies/µL SEGP-G y = −3.1118x + 52.05 R 2 = 1 10 4 RNA copies/µL TENP-P y = −3.1736x + 53.329 R 2 = 1 10 5 RNA copies/µL TBENP-Z y = −3.3521x + 56.003 R 2 = 1 10 5 RNA copies/µL (TAFV) TEGP-T y = −3.1179x + 56.335 R 2 = 1 10 6 RNA copies/µL TEVP40-D y = −3.3279x + 47.471 R 2 = 1 10 3 RNA copies/µL BENP-T y = −3.5357x + 55.8 R 2 = 1 10 5 RNA copies/µL TBENP-Z y = −3.6682x + 57.733 R 2 = 1 10 5 RNA copies/µL (BDBV) REVP40-T y = −3.0955x + 52.095 R 2 = 1 10 4 RNA copies/µL In this case, 23 sets of primers and probes targeting the NP, GP and VP40 genes of the ebolaviruses RNA genome were used for the specific amplification of each of the 5 ebolavirus species (Table 1 ). The sensitivity of real-time RT-PCR assays for different ebolavirus species was firstly determined using serial dilutions of known amounts of in vitro RNA transcripts containing the CDS of NP, GP or VP40 from each species of ebolaviruses. Ct values of the range of dilutions covering 7-9 serially diluted RNA transcripts were used to draw standard curves. Each corresponding copy number was calculated based on the molecular weight of the target sequence. The potential detection limits for each species-specific assay were determined to be 1 to 10 4 RNA copies/µL for EBOV, 10 4 -10 5 RNA copies/µL for SUDV, 10 3 -10 6 RNA copies/µL for TAFV, 10 5 RNA copies/µL for BDBV and 10 4 RNA copies/µL for RESTV (Table 2 ). Among them, the potential detection limits for NP gene specific assays were 1-10 5 RNA copies/µL. While those for other gene-specific assays (GP and VP40) were higher (10 2 -10 6 RNA copies/µL). In particular, the potential detection limits for EBOV NP gene specific assays were 1-10 RNA copies/µL, while those for SUDV, TAFV and BDBV NP gene specific assays were much higher (10 5 RNA copies/µL. Similarly, the potential detection limits for EBOV GP-gene specific assays (10 2 -10 3 RNA copies/µL) were also lower than GP-gene specific assays for other species (10 4 -10 6 RNA copies/µL). After a summarization, we found that there were more assays for EBOV than for other species. In conclusion, the most sensitive among the 23 sets were those specific for EBOV NP(ZENP-W and ZSENP-Z), and the assays specific for the NP gene were generally the most sensitive also in the case of other ebolavirus species. No inhibition of the assays at high concentrations of RNA (10 12 copies/µL). Next, the sensitivity of the real-time RT-PCR assays was evaluated using the viral RNA extracted from the serial dilutions of known titre of virus stock ( Table 3 ). The potential detection limits for each assay were 1-100 TCID 50 /mL (where TCID 50 is the 50% tissue culture infective dose). All tests were repeated more than three times and the inter-assay coefficients of variation (CVs) of Ct values were within the acceptable limit (<3%), indicating their reproducibility. Table 3 . The detection limits of the TaqMan RT-PCR assays for EBOV. The sensitivity of EBOV real-time RT-PCR assays was evaluated using viral RNA extracted from serial dilutions of known titre of virus stock. Amplification plots were realized on viral RNA extracted from 10-fold dilutions (10 −1~1 0 −7 dilution, i.e., 10 6~1 0 0 TCID50/mL) of virus-infected cell supernatants. The potential detection limits of ebolaviruses specific assays expressed in vitro RNA transcripts per microliter and 50% tissue culture infectious dose per milliliter (TCID 50 /mL) are summarized and compared in Table 4 . The sensitivities of the EBOV specific assays were consistent when expressed in both different units of measure. For example, ZENP-W, specific for EBOV NP, was the most sensitive assay and the potential detection limits for ZEGP-R were the highest among those specific for EBOV GP, whether evaluated using in vitro RNA transcripts (10 0 RNA copies/µL for ZENP-W and 10 6 RNA copies/µL for ZEGP-R) or viral RNA (1 TCID 50 /mL for ZENP-W and 100 TCID 50 /mL for ZEGP-R). The comparison also indicated different gene copy number for gene encoding different structural proteins in each virus particle. That is, if one copy of the NP gene was included in each infectious EBOV virus particle, there would be 10 times more GP gene copies and 1000 times more VP40 gene copies. To evaluate the specificity of these assays, cross-reactivity was examined using a variety of mimic viral RNA including Marburg virus (MARV), SUDV, TAFV, BDBV and RESTV (Table S1, Supplementary Materials). Marburg viruses can either cause similar symptomatology to ebolaviruses or could be a possible differential diagnosis to EVD. Each set showed highly positive fluorescence signals in the Ct range of 11.99-22.21 according to its own template, i.e., the RNA extracted from cells transfected with a specific gene expression plasmid. No cross-amplification reactions were observed. ZSENP-Z and TBENP-Z were designed to be simultaneously specific for two EBOV species. ZSENP-Z for EBOV and SUDV, whereas TBENP-Z for TAFV and BDBV (Table 5 and Figure 1 ). Figure 1 . Specificities of the ZBENP-Z and TBENP-Z assays were examined using a variety of mimic viral RNA including Marburg virus (MARV), SUDV, TAFV, BDBV and RESTV. They were designed to be simultaneously specific for two EBOV species: ZSENP-Z for EBOV and SUDV, whereas TBENP-Z for TAFV and BDBV RFU: relative fluorescence units. Most EBOV species-specific primer sets were designed using the consensus sequence derived from available sequences in GenBank. This was before the EVD outbreak in West Africa, and some mismatches were found between several EBOV variants and Makona variants, which were responsible for this West Africa outbreak. Fortunately, our tests indicated that most of EBOV-specific assays were also specific for the Makona variant (Table 6 and Table S2 , Supplementary Materials). Even though there were some differences in specificity for these two variants among four EBOV NP-specific assays (ZENP-H, ZENP-Y, ZENP-P and ZSENP-Z (p < 0.05), and significant difference between the other two assays: ZEGP-G and ZEVP40-R (p < 0.01) see Table 6 and Figure 2) . What need to be concerned was that the potential detection limit of the ZEVP40-R assay for the Makona variant was significantly higher than those for the Mayinga variant (Table 6 and Figure 2 ). This could be due to the several amino-acid changes in the Makona variant VP40 protein, which are conserved among most other EBOV isolates. Thus, it is recommended to develop a more specific assay targeted at the VP40 gene for the Makona variant. Most EBOV species-specific primer sets were designed using the consensus sequence derived from available sequences in GenBank. This was before the EVD outbreak in West Africa, and some mismatches were found between several EBOV variants and Makona variants, which were responsible for this West Africa outbreak. Fortunately, our tests indicated that most of EBOV-specific assays were also specific for the Makona variant (Table 6 and Table S2 , Supplementary Materials). Even though there were some differences in specificity for these two variants among four EBOV NP-specific assays (ZENP-H, ZENP-Y, ZENP-P and ZSENP-Z (p < 0.05), and significant difference between the other two assays: ZEGP-G and ZEVP40-R (p < 0.01) see Table 6 and Figure 2) . What need to be concerned was that the potential detection limit of the ZEVP40-R assay for the Makona variant was significantly higher than those for the Mayinga variant (Table 6 and Figure 2 ). This could be due to the several amino-acid changes in the Makona variant VP40 protein, which are conserved among most other EBOV isolates. Thus, it is recommended to develop a more specific assay targeted at the VP40 gene for the Makona variant. ZENP-H + − − − − − ZENP-W + − − − − − ZENP-Y + − − − − − ZENP-P + − − − − − ZENP-L + − − − − − ZEGP-T + − − − − − ZEGP-R + − − − − − ZEGP-G + − − − − − ZEGP-L + − − − − − ZEVP40−R + − − − − − ZSENP-Z + + − − − − SENP-T04 − + − − − − SENP-T08 − + − − − − SENP-P − + − − − − SENP-W − + − − − − SEGP-T − + − − − − SEGP-G − + − − − − TENP-P − − + − − − TBENP-Z − − + + − − TEGP-T − − + − − − TEVP40-D − − + − − − BENP-T − − − + − − REVP40-T − − − − + − The two deadliest ebolaviruses epidemics have occurred in the past 5 years, and one of these epidemics is still ongoing. In the case of an epidemic emergency, the first line of response should be an accurate and quick virus detection. Nucleic acid detection is the most common procedure for diagnosing EVD because of its unsurpassed specificity and sensitivity, as well as its ability to detect acute infection. Additionally, the virus does not need to be viable at the time of testing [38] . In recent years, real-time RT-PCR for the diagnostics of emerging virus infection has proven to be an invaluable tool for case identification and epidemic control [39] [40] [41] , e.g., during the ongoing COVID-19 pandemic. The two deadliest ebolaviruses epidemics have occurred in the past 5 years, and one of these epidemics is still ongoing. In the case of an epidemic emergency, the first line of response should be an accurate and quick virus detection. Nucleic acid detection is the most common procedure for diagnosing EVD because of its unsurpassed specificity and sensitivity, as well as its ability to detect acute infection. Additionally, the virus does not need to be viable at the time of testing [38] . In recent years, real-time RT-PCR for the diagnostics of emerging virus infection has proven to be an invaluable tool for case identification and epidemic control [39] [40] [41] , e.g., during the ongoing COVID-19 pandemic. In addition, when evaluating the spread of an infectious disease, the deployment of any diagnostic effort must rely on available and validated methods because time is very limited for research or the development of new technologies in the context of an emergency. Here, we comprehensively summarized and compared the sensitivity, reproducibility, and specificity of 23 in house assays, thus contributing to the standardization of ebolavirus detection and quantification assays. Our summarization showed that more assays for EBOV (11 sets) than other ebolaviruses species as it has been responsible for the most epidemics and the highest fatality rate (Table 1) . We also showed the higher sensitivity for EBOV, especially for the EBOV NP gene target ( Table 2) . For example, ZSENP-Z, which was specific for EBOV and SUDV, had sufficient specificity, but its potential detection limit for SUDV (10 5 RNA copies/µL) was much higher than that for EBOV (10 0 RNA copies/µL), which would likely SUDV being overlooked when simultaneously detecting two viruses. Therefore, additional assays for other ebolaviruses species (SUDV, TAFV, BDBV and RESTV) with higher sensitivity and specificity should be developed in the future. In addition, assays specific for different EBOV variants should also be developed for future possible outbreaks, such as the Makona variant, which is responsible for the EBOV outbreak in West Africa and the ongoing outbreak in the Democratic Republic of Congo. In this study, we showed that some EBOV-specific assays (such as ZEVP40-R) were not sufficient to detect the Makona variant. Even though the conserved NP gene was shown a good target for sensitive and specific assays, we should also consider the different specificities of assays for different regions of this gene. For example, the specificities of ZENP-Wand ZENP-L were better than those of ZENP-H, ZENP-Y, ZSENP-Z and ZENP-P, whereby the latter targeted the region near the 5 end of the NP gene (in reference to the EBOV sequence NC_002549). The quantitative measurement of viral load is an important parameter in the management of EVD because viral load correlates with severity of disease, survival and infectivity [26, [42] [43] [44] [45] [46] [47] . Viral load measurements are also important to interpret the efficacy of candidate therapies and vaccines in animal models and human beings [42, 44] , as well as to interpret ebolaviruses persistence in and transmission risk from immune privileged body compartments and fluids, such as the male gonads or semen, eyes, CNS, breast milk and the intrauterine space in pregnant women [48] [49] [50] [51] [52] . Additionally, ebolaviruses have occasionally been found in sweat and urine [53] , and in atypical or asymptomatic cases [52] . Viral load measurement could even be useful in assessing environmental decontamination practices [54] . As known, real-time RT-PCR not only provides a qualitative diagnosis but is also a direct measure of the virus load in a sample via determining the cycle threshold. For example, during the ongoing EVD outbreak in parts of Western Africa, more than 44 diagnostic laboratories yielded qualitative results for the detection of EVD [55] . Even though several real-time RT-PCR assays for Ebola virus are commercially available, none of them have been validated for quantitative viral load assessment. The reported sensitivities of these assays vary substantially depending on the reagents and other materials. Moreover, various in-house quantitative assays for detecting the viral load of ebolaviruses have been described, as summarized in this study, however, most of these assays have not been externally standardized or validated. Limits of detection depend on the PCR platform used and are not uniformly reported. Thus, data gathered between laboratories generally cannot be compared, because each laboratory possibly used distinct and specific assays under variable conditions [56] . A 1-2 log10 difference in viral load may be within the margin of error of RT-PCR testing across and within laboratories and assays. Here 23 assays for ebolavirus were compared using good research laboratory practices for the quantitative measurement of viral load in virus stock using the same synthetic RNA standard (RNA copies/µL), which could be used to standardize results across laboratories and time points. Furthermore, 11 sets for EBOV among them were further evaluated and compared using serial dilutions of known titre of virus stock (TCID 50 /mL). Our analysis showed that there was no substantial difference in the quantitative measurement of viable viral load across the two measures of potential detection limits. However, it will be easier and safer for these assays to implement synthetic RNA as a quantitative measurement standard (RNA copies/µL) in resource-limited settings and under outbreak conditions. As the viral load does not necessarily correlate with viable replicating ebolavirus, RNA copies per µL was more applicable for use in environmental decontamination assessment than TCID 50 /mL. Quantitative assays are labor intensive and not very easy to implement under field conditions, while the results might not be universally replicable, because they could vary depending on different reagents, machines and technician experience. Viral load determination has become a routine test for some virus diseases, such as HIV/AIDS and SARS-CoV-2/COVID-19, and it has the basis of clinical patient management. A path forward might be gleaned from concerted international efforts to develop standardized quantitative assays and reference materials. Virologists could work at the international level to standardize techniques and validate a robust field reference [37, 57] . This is another important concern that we addressed here by standardizing 23 assays for different ebolaviruses species under the same conditions, i.e., the same reagent, the same machine. We uniformly reported the potential detection limits as RNA copies per µL and TCID 50 per mL. We believe that these results could contribute to the standardization and validation of assays for ebolaviruses detection and quantification, as well as enable rapid, accurate and easy-to-implement EVD diagnostic methods in resource-limited settings and under outbreak conditions. Of course, the commutability of some materials might need additional work to yield consensus, and these efforts are clearly expected to have a positive effect on assay comparability. All efforts toward standardizing ebolaviruses assays hold the promise of similar effects and should be vigorously pursued. Supplementary Materials: The following are available online at https://www.mdpi.com/article/10.3 390/v13081575/s1, Table S1 : The specificity of TaqMan RT-PCR assays for different Ebola virus species. The specificity was evaluated firstly by using the simulating viral RNA extracted from cells transfected with recombinant plasmid containing Ebola virus NP, GP and VP40 gene. Table S2 : Specificity of EBOV species specific real-time RT-PCR assays for EBOV-Mayinga strain and Makona variant. The Pathogenesis of Ebola Virus Disease Marburg and Ebola viruses Filovirus Disease Outbreaks: A Chronological Overview Ebola outbreak in west Africa is officially over A review of epidemiological parameters from Ebola outbreaks to inform early public health decision-making Ebola Virus Disease-Democratic Republic of the Congo; Dis Outbreak News Ebola virus disease outbreak in Équateur Province, Democratic Republic of the Congo: A retrospective genomic characterisation Basic Clinical and Laboratory Features of Filoviral Hemorrhagic Fever Paving the Way for Its Use in High-Risk Countries Ebola experts seek to expand testing Cutaneous manifestations of filovirus infections Viral hemorrhagic fever in the tropics: Report from the task force on tropical diseases by the World Federation of Societies of Intensive and Critical Care Medicine After Ebola in West Africa-Unpredictable Risks, Preventable Epidemics Molecular diagnostics of viral hemorrhagic fevers Evaluation of a point-of-care blood test for identification of Ebola virus disease at Ebola holding units ReEBOV Antigen Rapid Test kit for point-of-care and laboratory-based testing for Ebola virus disease: A field validation study The role of rapid diagnostics in managing Ebola epidemics Comparison of sample types and diagnostic methods for in vivo detectionof Mycoplasma hyopneumoniae during early stages of infection Ebola virus disease diagnosis by real-time RT-PCR: A comparative study of 11 different procedures Rapid Detection and Quantification of RNA of Ebola and Marburg Viruses, Lassa Virus, Crimean-Congo Hemorrhagic Fever Virus, Rift Valley Fever Virus, Dengue Virus, and Yellow Fever Virus by Real-Time Reverse Transcription-PCR Development and evaluation of a fluorogenic 5 nuclease assay to detect and differentiate between Ebola virus subtypes Zaire and Sudan Rapid detection of filoviruses by real-time TaqMan polymerase chain reaction assays High-Throughput Molecular Detection of Hemorrhagic Fever Virus Threats with Applications for Outbreak Settings Comprehensive Panel of Real-Time TaqMan™ Polymerase Chain Reaction Assays for Detection and Absolute Quantification of Filoviruses, Arenaviruses, and New World Hantaviruses World Health Organization. Laboratory Diagnosis of Ebola Virus Disease; World Health Organization Rapid Diagnosis of Ebola Hemorrhagic Fever by Reverse Transcription-PCR in an Outbreak Setting and Assessment of Patient Viral Load as a Predictor of Outcome The evaluation of 7 commercial real-time PCR kits for Zaire ebolavirus using virus-like particle-encapsulated EBOV RNA Rapid detection protocol for filoviruses Multiplex real-time PCR method for rapid detection of M arburg virus and Ebola virus Comprehensive multiplex one-step re-al-time TaqMan qRT-PCR assays for detection and quantification of hemorrhagic fever viruses Detection of Zaire Ebola virus by real-time reverse transcrip-tion-polymerase chain reaction Rapid detection and quantification of Ebola Zaire virus by one-step re-al-time quantitative reverse transcription-polymerase chain reaction Establishment of real-time fluorescence-based quantitative PCR method for detect-ing Zaire ebolavirus. Mod Newly Discovered Ebola Virus Associated with Hemorrhagic Fever Outbreak in Uganda Development of a duplex fluorescence RT-PCR assay for detecting four pathogenic subtypes of Ebola virus Sensitive Multiplex Real-time RT-qPCR Assay for the Detection of Filoviruses Networking for training Level 3/4 biosafety laboratory staff Viral Hemorrhagic Fever Diagnostics Zika plasma viral dynamics in nonhuman primates provides insights into early infection and antiviral strategies Modelling Ebola virus dynamics: Implications for therapy Persistence and clearance of Ebola vi-rus RNA from seminal fluid of Ebola virus disease survivors: A longitudinal analysis and modelling study The contribution of Ebola viral load at admission and other patient charac-teristics to mortality in a Médecins Sans Frontières ebola case management centre Clinical illness and outcomes in patients with Ebola in Sierra Leone Blood kinetics of Ebola virus in survivors and nonsurvivors Ebola viral load at diagnosis associates with patient outcome and outbreak evolution Ebola Virus Epidemiology, Transmission, and Evolution during Seven Months in Sierra Leone Clinical Presentation of Patients with Ebola Virus Disease in Conakry Molecular Evidence of Sexual Transmission of Ebola Virus Persistent Ebola Virus in the Eye British nurse makes "full recovery" from reactivated Ebola virus Lactating mothers infected with Ebola virus: EBOV RT-PCR of blood only may be insufficient Shedding of Ebola Virus in an Asymptomatic Pregnant Woman A case of severe Ebola virus infection complicated by Gram-negative septicemia Assessment of the Risk of Ebola Virus Transmission from Bodily Fluids and Fomites Clinical features and viral kinetics in a rapidly cured patient with Ebola virus disease: A case report Experimental treatment with favipiravir for Ebola virus disease (the JIKI Tri-al): A historically controlled, single-arm proof-of-concept trial in Guinea Informed Consent Statement: Not applicable. The authors declare that they have no conflict of interest.