key: cord-0925501-9c67oha0 authors: Zhao, Fei; Lu, Jinxing; Lu, Bing; Qin, Tian; Wang, Xuemei; Hou, Xuexin; Meng, Fanliang; Xu, Xiaona; Li, Tianyi; Zhou, Haijian; Zhang, Jianzhong; Kan, Biao; Huang, Ying; Zhang, Zehui; Xiao, Di title: A Novel Strategy for the Detection of SARS-CoV-2 Variants Based on Multiplex PCR-Mass Spectrometry Minisequencing Technology date: 2021-11-17 journal: Microbiol Spectr DOI: 10.1128/spectrum.01267-21 sha: ffd476b67324082f953a838d12f733f8636c710c doc_id: 925501 cord_uid: 9c67oha0 The objective of this study was to construct a novel strategy for the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants using multiplex PCR-mass spectrometry minisequencing technique (mPCR-MS minisequencing). Using the nucleic acid sequence of a SARS-CoV-2 nonvariant and a synthetic SARS-CoV-2 variant-carrying plasmid, a matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) method based on the single-base mass probe extension of multiplex PCR amplification products was established to detect 9 mutation types in 7 mutated sites (HV6970del, N501Y, K417N, P681H, D614G, E484K, L452R, E484Q, and P681R) in the receptor-binding domain of the spike protein of SARS-CoV-2 variants. Twenty-one respiratory tract pathogens (9 bacteria and 12 respiratory viruses) and nucleic acid samples from non-COVID-19 patients were selected for specific validation. Twenty samples from COVID-19 patients were used to verify the accuracy of this method. The 9 mutation types could be detected simultaneously by triple PCR amplification coupled with MALDI-TOF MS. SARS-CoV-2 and six variants, B.1.1.7 (Alpha), B.1.351 (Beta), B.1.429 (Epsilon), B.1.526 (Iota), P.1 (Gamma) and B.1.617.2 (Delta), could be identified. The detection limit for all 9 sites was 1.5 × 10(3) copies. The specificity of this method was 100%, and the accuracy of real-time PCR cycle threshold (C(T)) values less than 27 among positive samples was 100%. This method is open and extensible, and can be used in a high-throughput manner, easily allowing the addition of new mutation sites as needed to identify and track new SARS-CoV-2 variants as they emerge. mPCR-MS minisequencing provides a new detection option with practical application value for SARS-CoV-2 and its variant infection. IMPORTANCE The emergence of SARS-CoV-2 variants is the key factor in the second wave of the COVID-19 pandemic. An all-in-one SARS-CoV-2 variant identification method based on a multiplex PCR-mass spectrometry minisequencing system was developed in this study. Six SARS-CoV-2 variants (Alpha, Beta, Epsilon, Iota, Gamma, and Delta) can be identified simultaneously. This method can not only achieve the multisite simultaneous detection that cannot be realized by PCR coupled with first-generation sequencing technology and quantitative PCR (qPCR) technology but also avoid the shortcomings of time-consuming, high-cost, and high technical requirements of whole-genome sequencing technology. As a simple screening assay for monitoring the emergence and spread of SARS-CoV-2 and variants, mPCR-MS minisequencing is expected to play an important role in the detection and monitoring of SARS-CoV-2 infection as a supplementary technology. S evere acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has spread worldwide since the end of 2019. The second wave of COVID-19 has been incessantly causing catastrophe worldwide. The emergence of SARS-CoV-2 variants is the key factor in the second wave of the COVID- 19 (1, 2) . Some reports suggest that these variants have important mutations in the receptor-binding domain (RBD) of the spike protein of SARS-CoV-2 that increase the transmission efficiency of the virus, increase the severity of the disease, enhance the immune escape ability of the virus, and reduce the immune effect of the current vaccines (3) (4) (5) (6) ; this has not been proven to be universally true. Currently, the mutation and evolution of SARS-CoV-2 are mainly detected by whole-genome sequencing (WGS) (7) (8) (9) (10) (11) . Although genome sequencing is the gold standard for identifying SARS-CoV-2 variants, routine genomic testing is expensive and difficult to perform in real time and is not available in many areas due to lack of resources and expertise. Quantitative PCR (qPCR) (12) , melting-temperature RT-PCR (13) , and CRISPR-Cas13a-based transcription amplification were general used for the single-site detection of SARS-CoV-2 variants (14) . Therefore, the rapid, accurate, economic, and multisite detection method of SARS-CoV-2 variant identification is an urgent technical system for SARS-CoV-2 infection prevention and control worldwide. Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has been utilized for detecting single nucleotide polymorphisms (SNPs) in recent decades, and the basic process is as follows. Multiplex PCR is used to amplify the genes containing the targets of SNPs. Subsequently, an extension mass probe is utilized for the extension of SNP sites. Finally, MALDI-TOF MS is performed to identify the mass-to-charge ratio (m/z) of extended mass probes. In order to understand and distinguish from other mass spectrometry techniques, we named this technique of detecting SNPs by multiplex PCR coupled with MALDI-TOF MS as multiplex PCR-mass spectrometry minisequencing (mPCR-MS minisequencing) technology. In recent years, MALDI-TOF MS has been commonly used in clinical hospitals, the Center for Disease Control and Prevention, and research institutes in many countries for microbiological detection and analysis (15) (16) (17) . To date, multiple-SNP detection and diagnosis of various viral infections based on MALDI-TOF MS have been frequently conducted (18) (19) (20) . Our team has also completed a multisite SNP genotyping and macrolide susceptibility gene method for Mycoplasma pneumoniae using mPCR-MS minisequencing. SNP analysis based on MALDI-TOF MS features high-throughput, rapid detection and simultaneous detection of multiple targets (21) . Therefore, it is one of the most promising biomolecular techniques. In this study, 9 mutation types of 7 mutation sites in the RBD of the spike protein were detected simultaneously by using mPCR-MS minisequencing technology for the identification all current SARS-CoV-2 variants. MPCR-MS minisequencing-based method establishment and optimization. The nine targets were amplified by triple PCR. The m/z of mass probe extension (MPE) original peaks at 9 mutation types (HV69-70del, N501Y, K417N, P681H, D614G, E484K, L452R, E484Q, and P681R) were 5,170 6 3, 5,105 6 3, 5,794 6 3, 6,036 6 3, 5,816 6 3, 6,436 6 3, 5,691 6 3, 6,436 6 3, and 6,036 6 3, respectively (mass error less than 500 ppm; the same below). The m/z of MPE peaks of these 9 mutation types of SARS-CoV-2 nonvariants were 5,483 6 3, 5,402 6 3, 6,067 6 3, 6,309 6 3, 6,113 6 3, 6,749 6 3, 5,988 6 3, 6,749 6 3, and 6,309 6 3, and the extension bases were C, A, G, C, A, G, G, G, and C. The m/z of MPE peaks of these 9 mutation types of the S genemutated plasmid of SARS-CoV-2 variants were 5,512 6 3, 5,447 6 3, 6,091 6 3, 6,333 6 3, 6,129 6 3, 6,733 6 3, 5,964 6 3, 6,709 6 3, and 6,349 6 3, respectively, and the extended bases were A, T, T, A, G, A, G, C, and G (Fig. 1 ). All mutation types were identified correctly using mPCR-MS minisequencing methods. Detection limit and specificity of mPCR-MS minisequencing. The extended signals of mass probe pairs 5,483 6 3/5,512 6 3 (HV69-70del), 5,402 6 3/5,447 6 3 (N501Y), 6,067 6 3/6,091 6 3 (K417N), 6,309 6 3/6,333 6 3 (P681H), 6,309 6 3/6,349 6 3 (P681R), 6,113 6 3/6,129 6 3 (D614G), 6,749 6 3/67,33 6 3 (E484K), 6,749 6 3/6,709 6 3 (E484Q), and 5,988 6 3/5,964 6 3 (L452R) were not detected in 21 other respiratory pathogen and non-COVID-19 patient nucleic acids, which showed that the specificity of this method was 100%. The detection limits for HV69-70del, K417N, E484K, N501Y, D614G, P681H, L452R, E484Q, and P681R were 400, 1,560, 400, 400, 400, 1,560, 400, 400, and 1,560 copies, respectively, and the total detection limit for all sites of the mPCR-MS minisequencing was 1,560 copies when using the diluted concentration of the nucleic acids of the SARS-CoV-2 nonvariants (Fig. 2) . The mutation sites were detected by synthetic DNA plasmids, and the detection limits of all the sites were between 100 and 400 copies. Detection results of clinical nucleic acid specimens. The threshold cycle (C T ) values of RT real-time PCR (FAM fluorescence signal C T value of N gene) of nucleic acid samples of 20 COVID-19 patients were 16.04 to 34.95, among which 13 samples with CT within 27 were all positive in the 7 target sites, and three mutations (delta variant) were found. Of the seven specimens with CT values were around 30, some of the sites were detected in 5, and none of the sites were detected in one specimen (Table 1) . In view of the emerging SARS-CoV-2 variants, researchers are trying to develop rapid detection methods in addition to genome sequencing. Based on the existing technology, all variants cannot be detected simultaneously by qPCR or CRISPR-Cas13a amplification technology. In this study, we developed a mPCR-MS minisequencing method that can simultaneously detect 9 mutation types in 7 mutated sites in the RBD of spike proteins HV69-70del (Alpha), N501Y (Alpha, Beta, and Gamma), K417N (Beta), P681H (Alpha), D614G (Alpha, Beta, Gamma, Epsilon, Iota, and Delta), E484K (Beta and Gamma), L452R (Delta and Epsilon), P681R (Delta), and E484Q (B.1.617.1 and B1.617.3) to identify SARS-CoV-2 and its mutated variants. The workflow of this method is shown in Fig. 3 . Through combination of the results of the nine mutation sites, we can judge whether the detected sample is a SARS-CoV-2 infection, and if it is a SARS-CoV-2 infection, we can also determine which variant strain is present ( Table 2) . The Indian variant strain B.1.617 lineage includes three main subtypes, B1.617.1, B1.617.2, and B1.617.3. Delta variant (B1.617.2) has been detected in many countries and was believed to spread faster than other variants, and it notably escapes neutralizing monoclonal antibodies and polyclonal antibodies elicited by previous infection with SARS-CoV-2 or by vaccination (22, 23) . The method constructed in this study can simultaneously detect 9 mutation sites, which can accurately judge whether the sample is infected by the Delta variant. In the 20 clinical samples, 3 Delta variants were correctly identified according to our judgment rules ( Table 2 ). The nucleic acid load of the samples with real-time PCR C T values greater than 27 was roughly estimated to be less than 1,000 copies, which was lower than the detection limit of some sites. Therefore, only a portion of sites were detected in six samples with C T values greater than 27, and one sample was negative. The reliability of the method is verified by the detection of clinical samples, which indicates that the method has clinical application value. This method can not only detect SNP gene mutation but also detect gene variation caused by deletion and insertion according to probe extension. The type of extended base was determined according to the peak value (m/z) acquired by MALDI-TOF MS. For example, for the HV69-70del site, if the peak of the detected extension product was 5,483 6 3, then the extension base was C, indicating that CATGTC (HV69-70R) was not deleted and the detected sample was a non-SARS-CoV-2 variant; if the peak of the detected extension product was 5,512 6 3, then the extension base was A, indicating that CATGTC was deleted (Fig. 4 ) and the detected sample was a SARS-CoV-2 variant. If these two characteristic peaks were not detected, the sample was not infected with SARS-CoV-2. The detection of mutation sites through the same principle (Fig. 4) . This method relies on MPE probe detection after PCR amplification and has high specificity. There was no nonspecific identification in various non-SARS-CoV-2 pathogens (9 bacteria and 12 respiratory viruses) or nucleic acid samples from non-COVID-19 patients. The method of detection of mutation sites based on PCR and firstgeneration sequencing technology has a high requirement for the quantity of PCR amplification products. PCR products with insignificant electrophoretic bands often fail to be sequenced due to insufficient quantity. However, the mPCR-MS minisequencing requires fewer PCR products than sequencing when extending the MPE probe. The PCR products, which are not obvious in electrophoretic bands or even hard to be observed by the naked eye, can also be detected by MALDI-TOF MS after MPE extension. Therefore, for mPCR-MS minisequencing, the detection limit is affected by both multiplex PCR amplification and MPE probe extension, and there are great differences among different mutation sites. For example, D614G and P681H are located in the same PCR amplification fragment. The detection limit of D614G is 400 copies after MPE extension, while that of P681H/R is only 1,560 copies, indicating that the probe extension efficiency of P681H/R is much lower than that of D614G, which is closely related to the base sequence near the detection site of P681H/R. Although the detection limit of the mutant site of synthetic plasmid is lower (100 to 400 copies), considering the lack of RNA virus reverse transcription step in the process of plasmid DNA amplification, we still use the lowest detection limit (LDL) of nucleic acid amplification of SARS-CoV-2-infected samples (1,560 copies) as the LDL of this method. PCR coupled with first-generation sequencing technology is only suitable for the detection of multiple mutation sites in a nucleic acid sequence of less than 600 bp and cannot be used for the detection of all mutation sites of SARS-CoV-2 (2,000 bp). qPCR is only suitable for the detection of single mutation sites. WGS is time-consuming and high cost and has high technical requirements, so it is only suitable for mutation site This study developed a novel strategy for detecting SARS-CoV-2 variants. However, this method has some limitations. First, the 39-terminal sequence of the extension probe is fixed, and the quality of the probe is greatly influenced by the base sequence near the detection site, which can lead to the inefficient detection in extreme cases. Second, in some HV69-70del mutants, in addition to six bases (CATGTC), the front base of these six bases also had an A-C mutation. The extension probe of HV69-70del could not effectively distinguish the A-C mutation, which does not affect the accuracy for the other six SNP sites. Third, the number of clinical specimens used in this study is limited, and the number of validation specimens needs to be further increased. As a simple screening assay for monitoring the emergence and spread of these SARS-CoV-2 variants, mPCR-MS minisequencing may be helpful for implementing public health strategies to counter these and future mutation strains. Specimens and nucleic acids of SARS-CoV-2. The nucleic acid of the SARS-CoV-2 clinical isolate (nonvariant) was obtained from the Institute of National Institute for Communicable Disease Control and Prevention, Chinese Center for Disease Control and Prevention (ICDC). The S gene mutation plasmids (plasmid 1, containing the HV69-70del, K417N, E484K, N501Y, D614G, and P681H mutations, and plasmid 2, containing the L452R, E484Q, and P681R mutations) of SARS-CoV-2 variants (Alpha, Beta, Iota, Epsilon, Gamma, and Delta) were synthesized by Sangon Biotech (Shanghai, China) . The nucleic acids of 21 common respiratory tract pathogens, including Mycoplasma pneumoniae (ATCC 29342), Escherichia coli (ATCC 11229), Streptococcus pneumoniae (ATCC 49619), Staphylococcus aureus (ATCC 29213), Legionella pneumophila (clinical isolate), Mycobacterium tuberculosis (clinical isolate), Pseudomonas aeruginosa (clinical isolate), Haemophilus influenzae (clinical isolate), Neisseria meningitidis (clinical isolate), influenza A virus, influenza B virus, parainfluenza viruses I, II, III, and IV, adenovirus, rhinovirus, coronaviruses 229E, OC43, and NL63, and respiratory syncytial virus, and non-COVID-19 patient sputum and bronchoalveolar lavage fluid specimens were selected for specific validation of this method. The nucleic acids of 20 clinical samples of COVID-19 patients (kept at the ICDC) were used to verify the accuracy of this method. All the specimens collected from COVID-19 patients were collected with complete informed-consent procedures. This study was approved by the ethics committee of the ICDC. Design of amplification primers and extension probe for the variant sites. Three sets of PCR primers were designed to amplify the related fragments of the nine mutation types ( Table 3 ). The S-F1/R1 amplification product contained one mutation type (HV69-70del), the S-F2/R2 amplification product contained five mutation types (K417N, E484K, E484Q, N501Y, and L452R), and the S-F3/R3 amplification product contained three mutation types (D614G, P681H, and P681R). The lengths of primers ranged from 19 bp to 22 bp, and the molecular weight of each primer was made more than 9 kDa (beyond the mass range of the mass extension probe) by adding a 10-bp fixed sequence (ACGTTGGATG) to the 59 end of each primer. MALDI-TOF MS quality difference probes for mutation sites were designed by using the IntelliBio genetic locus analysis software (V2.0, IntelliBio, China) ( Table 3 ). The molecular weight of the mass probe was required to be 4 to 9 kDa and the length was 17 to 28 bp, and a minimal difference between the probe molecular weights was set for 20 Da. Establishment of mPCR-MS minisequencing method. SARS-CoV-2 nonvariants and S gene mutant plasmids of SARS-CoV-2 variants were used as templates to construct the analysis method. Nucleic acid-free water served as the blank control. The specific steps were as follows. (i) For multiplex PCR amplification, the mutated gene fragment was amplified by an AgPath-ID one-step RT-PCR kit. (ii) For shrimp alkaline phosphatase (SAP) digestion, PCR products were treated with SAP to eliminate the free deoxynucleoside triphosphates (dNTPs). (iii) For mass probe extension (MPE), the purified PCR products were added with mixed MPE probes for single base extension, and the mutation sites were detected. (iv) For desalination and purification, an appropriate amount of resin was added to the extension product, turned over and mixed for 30 min, and centrifuged, and the supernatant was subjected to MALDI-TOF MS. SNP identification and data analysis by MALDI-TOF MS. 3-Hydroxypyridine-2-carboxylic acid (3-HPA; 0.9 ml) was dropped at the center of the sample target. After drying, the matrix was covered with 0.3 ml of purified supernatant. Then the samples were subjected to testing after crystallization. The data were acquired from the QuanTOF I system (Intelligene Biosystems, Qingdao, China). The parameters and data analysis were previously described (21) . Determination of the detection limit and specificity. The lowest detection limit (LDL) of PCR-MALDI-TOF MS was determined by using RNA of SARS-CoV-2 nonvariants and the mutant DNA plasmids of the S gene. The original concentration of nucleic acids was quantified (Qubit 3.0) and diluted in 7 The 10-bp fixed sequence added to the 59 end of the primer is indicated by lowercase. concentration gradients. The specificity of this method was validated by 21 kinds of nucleic acids of the other respiratory pathogens (9 bacteria and 12 respiratory viruses) and human sputum and bronchoalveolar lavage fluid nucleic acid extraction. Nucleic acid validation of COVID-19 patient specimens using mPCR-MS minisequencing. The nucleic acid of specimens of 20 COVID-19 patients was used to test the accuracy of this method. These specimens were also detected with a 2019-nCoV RT real-time PCR detection kit (Da An Gene Co., Ltd.) and WGS. Emergence of a new SARS-CoV-2 variant in the UK Features, evaluation, and treatment of coronavirus (COVID-19) Emergence of SARS-CoV-2 B.1.1.7 lineage-United States Evidence of escape of SARS-CoV-2 variant B.1.351 from natural and vaccine-induced sera Higher infectivity of the SARS-CoV-2 new variants is associated with K417N/T, E484K, and N501Y mutants: an insight from structural data SARS-CoV-2 D614G variant exhibits efficient replication ex vivo and transmission in vivo Evaluating the effects of SARS-CoV-2 spike mutation D614G on transmissibility and pathogenicity Characterizations of SARS-CoV-2 mutational profile, spike protein stability and viral transmission Analytical validity of nanopore sequencing for rapid SARS-CoV-2 genome analysis COVID-Diagnosis HCL Study Group. 2021. Two-step strategy for the identification of SARS-CoV-2 variant of concern 202012/01 and other variants with spike deletion H69-V70 Whole-genome sequencing of SARS-CoV-2 reveals the detection of G614 variant in Pakistan Fast and cost-effective screening for SARS-CoV-2 variants in a routine diagnostic setting A simple RT-PCR melting temperature assay to rapidly screen for widely circulating SARS-CoV-2 variants Detection of SARS-CoV-2 and its mutated variants via CRISPR-Cas13-based transcription amplification Rapid and robust MALDI-TOF MS techniques for microbial identification: a brief overview of their diverse applications Application of the MALDI Biotyper to clinical microbiology: progress and potential Matrix-assisted laser desorption/ionization time-of-flight mass-spectrometry (MALDI-TOF MS) based microbial identifications: challenges and scopes for microbial ecologists Typespecific detection of 30 oncogenic human papillomaviruses by genotyping both E6 and L1 genes Sensitive and rapid detection of viruses associated with hand foot and mouth disease using multiplexed MALDI-TOF analysis Multiplex detection of human herpesviruses from archival specimens by using matrix-assisted laser desorption ionization-time of flight mass spectrometry A multisite SNP genotyping and macrolide susceptibility gene method for Mycoplasma pneumoniae based on MALDI-TOF MS Reduced sensitivity of SARS-CoV-2 variant Delta to antibody neutralization Effectiveness of Covid-19 vaccines against the B.1.617.2 (Delta) variant This work was supported by The Major Infectious Diseases AIDS and Viral Hepatitis Prevention and Control Technology Major Projects (grant no. 2018ZX10712001-006012).We declare no conflicts of interest.