key: cord-0926192-78vxse2c authors: Jia, Xiaofang; Hu, Lvyin; Wu, Min; Ling, Yun; Wang, Wei; Lu, Hongzhou; Yuan, Zhenghong; Yi, Zhigang; Zhang, Xiaonan title: A streamlined clinical metagenomic sequencing protocol for rapid pathogen identification date: 2021-02-23 journal: Sci Rep DOI: 10.1038/s41598-021-83812-x sha: f6a672b9038f704dc6755676fd881e005cd285ef doc_id: 926192 cord_uid: 78vxse2c Metagenomic next-generation sequencing (mNGS) holds promise as a diagnostic tool for unbiased pathogen identification and precision medicine. However, its medical utility depends largely on assay simplicity and reproducibility. In the current study, we aimed to develop a streamlined Illumina and Oxford Nanopore-based DNA/RNA library preparation protocol and rapid data analysis pipeline. The Illumina sequencing-based mNGS method was first developed and evaluated using a set of samples with known aetiology. Its sensitivity for RNA viruses (influenza A, H1N1) was < 6.4 × 10(2) EID50/mL, and a good correlation between viral loads and mapped reads was observed. Then, the rapid turnaround time of Nanopore sequencing was tested by sequencing influenza A virus and adenoviruses. Furthermore, 11 respiratory swabs or sputum samples pre-tested for a panel of pathogens were analysed, and the pathogens identified by Illumina sequencing showed 81.8% concordance with qPCR results. Additional sequencing of cerebrospinal fluid (CSF) samples from HIV-1-positive patients with meningitis/encephalitis detected HIV-1 RNA and Toxoplasma gondii sequences. In conclusion, we have developed a simplified protocol that realizes efficient metagenomic sequencing of a variety of clinical samples and pathogen identification in a clinically meaningful time frame. Historically, laboratory diagnosis of infectious diseases has relied largely on microscopic examination and culture in appropriate media or cell lines. The advent of molecular biological techniques and sensitive RNA/DNA detection-by-amplification methods has dramatically changed clinical practice for infectious diseases 1 . However, these tests require prior knowledge of the infectious agent, and not all molecular tests are readily available for all suspected pathogens in clinical practice. By contrast, metagenomic next-generation sequencing (mNGS) is a bias-free method that retains the key advantages of molecular tests and requires no information on the aetiology of the disease. This method allows the detection of a wide range of microbes (viruses, bacteria, fungi and parasites) present in a sample in a single assay [2] [3] [4] [5] [6] . In addition to clinical diagnosis, mNGS has also shown potential in the discovery of novel pathogens, and a case in point was the recent outbreak of infectious pneumonia caused by SARS-CoV-2 7, 8 . Thus, mNGS has widespread microbiological applications, including in infectious disease diagnosis in clinical laboratories 9 , pathogen identification for acute and chronic illnesses of unknown origin 10 , and outbreak surveillance on a global scale 7, 8, 11 . Despite the significant advantages of the mNGS approach, there are also several technical and regulatory obstacles to this method being widely applied in clinical practice. The most obvious limitation is that the whole process usually takes several days and involves a long chain of wet and dry laboratory activities whose reliability needs to be rigorously validated. In particular, the wet lab procedure usually involves the extraction of minute amounts of nucleic acids, which are subsequently transformed into sequencing-ready libraries with high molecular efficiency. Most of the reported mNGS methods have relied heavily on large amounts of basic research resources and prohibitive expenditure on consumables. This is particularly problematic in resource-poor areas. In addition, although genome sequencing technologies continue to develop with remarkable pace [12] [13] [14] [15] [16] [17] [18] , analytical approaches for reconstructing and classifying metagenomes from mixed samples remain limited in their performance and usability 19 . Finally, pre-validated reference databases and sequence analysis pipelines that factor in the common pitfalls of pathogen identification are needed for reliable reporting. In this study, we attempted to address some of the issues by developing a broadly applicable time-and costeffective mNGS method. Total nucleic acids from virus stocks and clinical samples, including throat swabs, Establishment of an Illumina-based mNGS method. First, a sensitive and streamlined metagenomic next-generation sequencing (mNGS) protocol was developed and evaluated using a series of virus-positive samples. The general assay workflow is depicted in Fig. 1 . Efficient sample lysis was performed using chaotropic salt-based buffer in combination with bead beating, followed by magnetic bead-based semiautomatic nucleic Total nucleic acids (TNAs) were extracted by bead beating and guanidinium isothiocyanate-based lysis. TNA was then collected and split into two aliquots for subsequent DNA and RNA library preparation, which were further analysed by Illumina-or Nanopore-based sequencing. The time consumption of each step, the total time spent and the cost estimate of the workflow are indicated. (b) Sequence analysis workflow. Sequences generated by Illumina and Nanopore sequencing were processed for alignment and classification. Reads were preprocessed by trimming adapters and removing low-quality/low-complexity sequences, followed by Centrifuge software analysis to taxonomically classify microbial reads into families, genera, or species and alignment to the specific sequence of candidate pathogens. We tested this assay using representative DNA and RNA viruses (HBV-positive serum, human adenovirus type 7 (AdV7), human adenovirus type (AdV3) and influenza A/Puerto Rico/8/1934 H1N1 (PR8)). The resulting sequencing reads (9.86-70.68 million filtered reads) enabled the recovery of full-length viral genomes with average coverage depths ranging from 3262.33 to 12,745.27 (Table 1) . To further assess the sensitivity of virus identification using our method, especially for RNA viruses, a dilution series of PR8 supernatants was tested. While a 1530.02 × (100% coverage) average depth was obtained for the original virus stock, and depths of 174.66 × (90.30% coverage) and 11.98 × (25.60% coverage) were achieved when the virus stock was diluted 1/100 and 1/10,000, respectively ( Table 2 and Fig. 2) . A good correlation between sample viral loads and the number of total mapped reads was observed (p = 0.02, r = 0.99, linear regression), while reads generated from the negative control showed no mapping. Although the genome coverage of the virus with the highest dilution factor (1/10,000, 6.4 × 10 2 EID50) decreased to 25.60% with a total of 1605 reads mapped to the PR8 genome, it was still more than sufficient for reliable identification. These results suggested that the limit of detection for PR8 was well below 6.4 × 10 2 EID50. Nanopore sequencing of RNA and DNA viruses. Single-molecule sequencing technology from Oxford Nanopore has the advantage of real-time data acquisition, which could significantly reduce the overall turn-around time. We first evaluated its performance on influenza A virus using the PR8 stock as a positive control. As shown in the cumulative read plot (Fig. 3a, Table 1 ), within the first minute, viral reads were sequenced and continued to accumulate. In the first 2 h, 2123 of the total 61,432 reads (3.46% mapping rate) were mapped to one of its eight segments. At the end of the run, 13,462 reads were mapped within 0.37 million reads. Nearfull coverage (99.46%) was obtained with an average depth of 407 ( Table 1 ). The genomic coverage plot of PR8 is shown in Fig. 3b . After sequencing the PR8 virus, we washed the sequencing chip and reloaded it with barcoded libraries generated with AdV3 and AdV7 DNA. Although the data generated were low due to inactivation of most of the pores, we still found 11 of 22 reads in AdV7 and 3 of 22 reads in AdV3. With such scarce read data, Nanopore sequencing allowed successful assembly of 67.50% and 23.10% of the genome sequences of AdV7 and AdV3 stocks, respectively ( Fig. 3c-d, Table 1 ). These results reflected the real-time sequencing capability of Nanopore technology. (Table 3) . DNA and RNA libraries were constructed independently for each clinical sample. RNA or DNA sequencing results with additional matching reads for each sample are shown in Table 3 . Among 10 samples that tested positive by the TaqMan array, 8 were positively detected by our mNGS workflow, which included two FluA H1N1, one FluA H3N2, two rhinoviruses, one coronavirus OC43 and two adenoviruses. Sequencing reads from two samples, which were positive for Haemophilus influenzae (sample #9) and FluA H1N1 (sample #10), did not meet the statistical criteria for pathogen calling. Sequencing results from one sample (sample #11) that tested negative using the array card did not show significant reads from these pathogens. Thus, our current mNGS sequencing method showed 81.8% (9 in 11) concordance with qPCR-based results. Due to the usually low level of pathogen nucleic acids, these samples yielded 1.00 to 85.29 mapped reads per million (RPM) with a genome coverage of 2.03%-98.75%. For sample #1 with a Ct value of 19.02, near full-length H1N1 viral genomes (98.75%) and an average depth of 13.84 were obtained (Table 3) . We then performed sequencing on 20 CSF samples from patients with meningitis/encephalitis caused by various factors (AIDS-related disease, suspected CNS infection). HIV-1 sequences were identified in two of these patients with mapping rates of 4.14 and 1425.45 RPM (Table 3) , and their serum HIV-1 RNA levels were 3.14 E + 04 and 7.57 E + 05 copies/mL, respectively. This confirmed previous reports of cerebral HIV-1 infection in some AIDS patients 20 . Furthermore, Toxoplasma gondii sequences (RPMsample = 18,024) were identified in one of these two samples (sample #12, Table 3 ) with a mapping ratio of 61.7 (RPM-r) compared to the blank control (RPM NTC = 292, data not shown). Indeed, an antibody test for Toxoplasma gondii was positive for this patient. This indicated the feasibility of identifying potential parasite infections in CSF samples using our protocol. The utilization of deep sequencing methodologies in the clinical diagnosis of infectious agents has profoundly improved the speed and precision of infectious disease management in the past decade. In 2014, by shot-gun metagenomic sequencing, Wilson et al. 14 reported the identification of Leptospira as the aetiology of an unusual case of severe meningoencephalitis, which was one of the earliest examples of the application of this new approach. mNGS has also become a powerful tool for unbiased pathogen detection and monitoring of viral transmission and evolution during outbreaks, which has been best exemplified in the current COVID-19 pandemic 7, 8, 21, 22 . These achievements have highlighted the unique value of deep sequencing for clinical practice and public health intervention. To fully unleash the diagnostic power of mNGS, tremendous efforts have been made in various key steps of clinical metagenomics, i.e., nucleic acid extraction, library preparation, host sequence depletion, pathogen sequence enrichment, etc. 2,23-30 . However, most of the reported methods have relied heavily on large amounts of basic research resources, entailing high infrastructure investment and prohibitive expenditure on consumables. The commercial kits used for nucleic acid extraction and DNA/RNA library preparation alone easily cost over 200 USD per sample, not to mention the sequencing cost. This is particularly problematic in resource-poor areas. Furthermore, the complex procedures used in sample preprocessing, host depletion and/or pathogen enrichment make these methods difficult to replicate in most clinical laboratories. With these limitations in mind, we aimed to develop an easy-to-perform mNGS assay with minimal reliance on commercial kits and with the fewest processing steps while retaining adequate sensitivity towards most www.nature.com/scientificreports/ pathogen types. The resulting workflow would be affordable and widely deployable in clinical settings. In our protocol, total nucleic acids were semi-automatically extracted by chaotropic solutions and purified by magnetic beads using in-house solutions and primary reagents ordered in bulk. In addition, we also developed an efficient library preparation protocol for nanogram levels of RNA based on the template-switching properties of some reverse transcriptases 16 . This in-house method dramatically reduced the cost of RNA sequencing (~ 100 USD/ sample for Illumina sequencing, ~ 300 USD for Nanopore sequencing). Moreover, we confirmed its sensitivity towards RNA viruses (< 6.4 × 10 2 EID50 for influenza A virus) to be at least comparable to that of reported methodologies 31 . It was also found to be sensitive enough for detecting a series of RNA viruses, including human rhinovirus, human coronavirus, and HIV-1. Our assay performed well in identifying DNA/RNA viruses in our Compared with the widely used sequencing-by-synthesis platforms (Illumina, Ion Torrent and PacBio sequencing), the more recently commercialized electric current sensing method (e.g., Oxford Nanopore) offers significant advantages in terms of speed and read length, making real-time data analysis feasible 32, 33 . Hence, it is suitable in the context of genomic sequencing of microbes that are important to public health, as well as in the diagnosis of infectious diseases 34 . This approach has been increasingly used for molecular epidemiological research on emerging infectious diseases [35] [36] [37] . In recognition of its potential, we developed a Nanopore-compatible RNA library preparation protocol based on the SMARTer-seq principle. We tested the applicability of the workflow on RNA and DNA viruses and realized same-day reporting (< 8 h) from sample to sequencing data. Our study still has a number of limitations. Additional workflow improvements are still needed and are underway in several aspects. First, targeted amplification of the 16S rRNA gene could provide the accuracy and sensitivity required for the identification of clinically important bacteria across species and genera 38, 39 . It dramatically reduces the need to eliminate human reads and increases sensitivity, especially for samples with high host cellular content. The development of Nanopore protocols for targeted sequencing of bacterial and fungal rRNA sequences would be complementary to our current method. Second, validation of Nanopore sequencing in clinical samples and evaluation of its detection limit compared to that of Illumina sequencing is necessary. Third, better sensitivity and genome coverage could be achieved by incorporating a targeted sequence capture panel 40 , although retaining assay simplicity would be a challenge. Finally, improved sequence analytics that are efficient, bias free and rigorously validated would ensure reproducibility of reports. In summary, a simplistic, low-cost NGS workflow that realized time-and labour-saving conversion from clinical samples to Illumina and Nanopore libraries was developed. This protocol could significantly lower the technical and economic barriers for clinical laboratories to deploy such techniques, especially in resource-poor regions. Ethics statement. This study was approved by the Shanghai Public Health Clinical Center Ethics Committee. All experimental protocols involving humans were in accordance with the guidelines of the Declaration of Helsinki. Informed consent was obtained from all enrolled patients. Nucleic acid extraction. Total nucleic acids (TNAs) were extracted by magnetic beads according to previously published papers with some modifications 43 ). The amplified product (13-15 cycles) was purified using AMPure XP beads. Sequencing was performed on a NovaSeq 6000 with a 2 × 150-bp paired-end sequencing protocol, and 10 to 150 million reads were generated for each sample. For each batch of samples, a pure water control or optionally a negative sample control (specific pathogen free) was included and analysed in parallel. Nanopore library preparation and sequencing. An influenza A strain, PR8, and two adenovirus B (AdV3 and AdV7) stocks were analysed by Nanopore sequencing as representative RNA and DNA viruses. TNA were extracted from these samples. For influenza A H1N1, viral RNA was reverse transcribed, and SINGV PCR was amplified (35 cycles) by the SMARTer-Seq protocol. The amplified products were purified using 0.6 × volume of VAHTS DNA Clean Beads (Vazyme Biotech Co., Ltd.). The extracted DNA products were quantified using the ds DNA HS Assay Kit on a Qubit 3.0 Fluorometer. Approximately 1 μg of amplified product was used for library construction using the SQK-LSK108 kit (Oxford Nanopore Technologies). Library construction was performed according to the manufacturer's instructions. For adenovirus B, TNA extracted from AdV3 and AdV7 stocks was used for library construction using the SQK-RPB004 kit (Oxford Nanopore Technologies) with 25 cycles of amplification. Each sample was amplified with a unique barcode primer provided in the kit. Libraries were sequenced on the MinION platform using R9 flow cells. The H1N1 sample was first loaded onto the R9 flow cell. After sequencing the H1N1 virus for 24 h, we washed the sequencing flow cell using the Wash Kit EXP-WSHSP2 (Oxford Nanopore Technologies) following the manufacturer's protocol and reloaded www.nature.com/scientificreports/ it with barcoded libraries generated with AdV 3 and 7 DNA. MinION was run for up to 24 h for each group of samples, and the first 2 h of data were used for data processing and alignment to evaluate the possibility of quick pathogen identification. Data analysis. Data analysis was performed in a Ubuntu20.04.1 LTS 64 bit system based on a workstation equipped with an Intel Xeon W-2133 CPU 3.6 GHz × 12, with 256 GB of memory and a 3.0-TB hard drive. The data were transferred to external hard drives for long-term storage. Paired-end 150-base-pair sequences generated by Illumina sequencing were processed for classification and mapping using our rapid computational pathogen detection pipeline (Fig. 1b) . First, reads were preprocessed by Fastp v 0.20.0 44 for trimming of adapters and removal of low-quality (q < 20), short (less than 30) and lowcomplexity sequences. Second, the qualified reads were mapped to the human reference genome using bowtie2 v 2.3.5 45 and samtools v 1.9 46 to remove human sequences. Third, the remaining unique, nonhuman sequences were taxonomically classified against the viral genomes or NCBI nucleotide sequences (NT database, 98 GB) using Centrifuge v 1.0.4 47 . Fourth, the unique, nonhuman reads were mapped against the curated RVDB viral sequence database 48 or the reference sequence of the specific pathogen selected from the Centrifuge output summary using bowtie2 (v2.3.5). Genome alignments and genome coverage (%) were visualized using Tablet (v19.09.03) 49 . The sequencing data were analysed in terms of the numbers of filtered reads, the number of reads aligned to the species-specific sequence, the number of mapped reads per million filtered reads, genome coverage (%) and coverage depth (average and maximum). For Illumina sequencing data, the analysis took approximately 2 h 20 samples. For Nanopore sequencing data, raw FAST5 files from the MinION instrument were base-called by Guppy (v 3.2.4). Base-called FASTQ files were processed by filtlong software (v0.2.0) for removal of low-quality (q > 7) and short (less than 100) sequences. The qualified reads were then aligned to the curated RVDB viral sequence database using minimap2 (v 2.17-r941). Mapped reads were exported to a bam file using samtools and visualized using Tablet. Identification of pathogens by minimap2-based pathogen-specific sequencing alignment could be performed within 10 min after real-time sequencing. All the Illumina and Nanopore sequencing raw data were deposited in the Sequence Read Archive (SRA) database with accession codes: PRJNA692001 (https ://www.ncbi.nlm.nih.gov/sra/PRJNA 69200 1). Positive reporting threshold and assay controls. For each batch of Illumina sequencing libraries, the "no template" control (NTC), i.e., nuclease-free water, was processed in parallel with samples, and the resulting reads were used as background references. Pathogen reporting threshold criteria were established to minimize false-positive results from contaminating microbial sequences. Identified RNA viruses were reported based on analysis of RNA mNGS libraries, whereas DNA viruses, bacteria, fungi, and parasites were reported based on analysis of a DNA or RNA library, depending on the abundance of the pathogen-mapped reads. For viruses, the threshold criteria were based on the detection of non-overlapping reads from ≥ 3 distinct genomic regions. For the identification of bacteria, fungi, and parasites, a reads per million (RPM) ratio metric (RPM-r) was used, defined as RPM-r = RPM sample /RPM NTC , with the minimum RPM NTC set to 1 27 . A minimum threshold of RPM-r ≥ 10 was designated for reporting the detection of a bacterium, fungus, or parasite. www.nature.com/scientificreports/ Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creat iveco mmons .org/licen ses/by/4.0/. PCR-based diagnostics for infectious diseases: uses, limitations, and future applications in acute-care settings Laboratory validation of a clinical metagenomic sequencing assay for pathogen detection in cerebrospinal fluid Enhanced methods for unbiased deep sequencing of Lassa and Ebola RNA viruses from clinical and biological samples Infection control in the new age of genomic epidemiology Genomic characterisation and epidemiology of 2019 novel coronavirus: implications for virus origins and receptor binding Understanding the Promises and Hurdles of Metagenomic Next-Generation Sequencing as a Diagnostic Tool for Infectious Diseases A new coronavirus associated with human respiratory disease in China A pneumonia outbreak associated with a new coronavirus of probable bat origin Next-generation and whole-genome sequencing in the diagnostic clinical microbiology laboratory Viral pathogen discovery Isolation of a novel coronavirus from a man with pneumonia in Saudi Arabia Rapid molecular microbiologic diagnosis of prosthetic joint infection Diagnosis of neuroinvasive astrovirus infection in an immunocompromised adult with encephalitis by unbiased next-generation sequencing Actionable diagnosis of neuroleptospirosis by next-generation sequencing Next-generation sequencing in neuropathologic diagnosis of infections of the nervous system Full-length RNA-seq from single cells using Smart-seq2 Smart-seq2 for sensitive full-length transcriptome profiling in single cells RNA sequencing by direct tagmentation of RNA/DNA hybrids Challenges in the analysis of viral metagenomes Persistent HIV-infected cells in cerebrospinal fluid are associated with poorer neurocognitive performance Viral and host factors related to the clinical outcome of COVID-19 A novel coronavirus from patients with pneumonia in China Retrospective validation of a metagenomic sequencing protocol for combined detection of RNA and DNA viruses using respiratory samples from pediatric patients Metagenomic nanopore sequencing of influenza virus direct from clinical respiratory samples Pulmonary metagenomic sequencing suggests missed infections in immunocompromised children BacCapSeq: a platform for diagnosis and characterization of bacterial infections Clinical metagenomic sequencing for diagnosis of meningitis and encephalitis Metagenomic sequencing with spiked primer enrichment for viral diagnostics and genomic surveillance Comprehensive human virus screening using high-throughput sequencing with a user-friendly representation of bioinformatics analysis: a pilot study Capturing sequence diversity in metagenomes with comprehensive and scalable probe design Use of Sequence-Independent, Single-Primer-Amplification (SISPA) for rapid detection, identification, and characterization of avian RNA viruses Rapid metagenomic identification of viral pathogens in clinical samples by real-time nanopore sequencing analysis Comparison of third-generation sequencing approaches to identify viral pathogens under public health emergency conditions Nanopore sequencing in a clinical routine laboratory: challenges and opportunities Coast-to-coast spread of SARS-CoV-2 during the early epidemic in the United States Genomic epidemiology of SARS-CoV-2 in Guangdong Province China Establishment and cryptic transmission of Zika virus in Brazil and the Americas Targeted next-generation sequencing of the 16S-23S rRNA region for culture-independent bacterial identificationincreased discrimination of closely related species 16S rRNA gene sequencing on a benchtop sequencer: accuracy for identification of clinically important bacteria Capturing the dynamics of genome replication on individual ultra-long nanopore sequence reads Extracellular hepatitis B virus RNAs are heterogeneous in length and circulate as capsid-antibody complexes in addition to virions in chronic hepatitis B patients Genome analysis of a novel recombinant human adenovirus type 1 in China Bio-On-Magnetic-Beads (BOMB): open platform for high-throughput nucleic acid extraction and manipulation fastp: an ultra-fast all-in-one FASTQ preprocessor Performance of genetic programming optimised Bowtie2 on genome comparison and analytic testing (GCAT) benchmarks The Sequence Alignment/Map format and SAMtools Centrifuge: rapid and sensitive classification of metagenomic sequences A reference viral database (RVDB) to enhance bioinformatics analysis of high-throughput sequencing for novel virus detection Using Tablet for visual exploration of second-generation sequencing data The authors acknowledge funding received from the following sources: the National Science and Technology Major Project of China (2017ZX10103009-001, 2018ZX10305409-001-005), the National Natural Science Foundation of China (grant no. 81801991, 81873962, 81671998, 91542207, 91842309), and the Chinese Foundation for Hepatitis Prevention and Control, TianQing Liver Disease Research Fund Subject (TQGB20200164). The funders had no role in the study design, data collection and analysis, decision to publish, or preparation of the manuscript. The authors declare no competing interests. Correspondence and requests for materials should be addressed to Z.Y. or X.Z.Reprints and permissions information is available at www.nature.com/reprints.Publisher's note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.