key: cord-0928933-1u4ak30k authors: Morikawa, Shigeru; Watanabe, Shunpei; Fujii, Hikaru; Tanaka, Toshio; Arai, Junichirou; Kyuwa, Shigeru title: Plasma irradiation efficiently inactivates the coronaviruses mouse hepatitis virus and SARS-CoV-2 date: 2020-11-13 journal: bioRxiv DOI: 10.1101/2020.11.13.381319 sha: 9166387c56065fae7e359ef681a95f6468b83914 doc_id: 928933 cord_uid: 1u4ak30k Many inactivation methods have been shown to inactivate SARS-CoV-2 for safe and efficient diagnostic methods. COVID-19 is caused by airborne infection of SARS-CoV-2, and therefore, methods of inactivating the virus efficiently and safely are crucial for reducing the risk of airborne infection. In this regard, the effect of plasma discharge on the infectivity of the coronaviruses mouse hepatitis virus (MHV) and SARS-CoV-2 was tested. Plasma discharge efficiently reduced the infectivity of both coronaviruses. Treatment of SARS-CoV-2 in culture medium with a plasma discharge resulted in 95.17% viral inactivation after plasma irradiation after 1 hour (hr), 99.54% inactivation after 2 hrs and 99.93% inactivation after 3 hrs. Similar results were obtained for MHV. The results indicated that plasma discharge effectively and safely inactivated the airborne coronaviruses and may be useful in minimizing the risk of airborne infection of SARS-CoV-2. Mouse astrocytoma-derived DBT cells were obtained from the Japanese Collection of Research Bioresources (https://cellbank.nibiohn.go.jp/english/) (JCRB) and cultured in Eagle's medium (MEM, Fujifilm Woko Chemicals, Japan) supplemented with 5% heat- A plasma discharge apparatus was used to irradiate the viruses in the media. Part of the plasma discharge device was mounted on one of a series of streamer air purifier products of Daikin Industries, Ltd., and a high voltage was applied to a discharge device having multiple pairs of discharge electrodes to cause a streamer discharge. In the experiment, the virus was placed in a 6-well plate (0.5 mL/well) without a top cover (Product No. 3335, Corning, NY), and the discharge device was placed 10 cm above the plate. The entire experimental system was placed in an acrylic container having an internal volume of 30.9 L (24 cm  46 cm  28 cm) and sealed. After applying a voltage of 6-7 kV between the electrodes to cause a current of 55 μA and exposing the virus to the plasma at 25 °C for 0, 1, 2, and 3 hours, respectively, then the virus was collected and subjected to virus infectivity titration. Titration of MHV was performed as described previously. Briefly, DBT cells seeded on 60 mm dishes were inoculated with serially 10-fold diluted samples and incubated at 37 °C for 1 hr in a 5% CO 2 incubator. Then the inoculum was replaced with an agarose medium consisting of MEM supplemented with 2% FBS, 1% (w/v) tryptose phosphate broth, 1% agarose and antibiotics and then cultured for 2 days at 37 °C in 5% CO 2 . The plaques caused by MHV infection were stained by an overlay of agarose medium containing 0.01% neutral red (Sigma-Aldrich). The infectious titer of MHV was expressed as a plaque-forming unit (pfu)/mL. The infectious titer of SARS-CoV-2 was obtained as a 50% tissue culture infectious dose (TCID 50 /mL). The Vero E6/TMPRSS2 cells cultured in 96-well microplates were inoculated with serially 10-fold diluted samples (each 6-wells/dilution) and incubated for 4 days at 37 °C in 5% CO 2 . The numbers of wells showing cytopathic effect (CPE) at each dilution were counted, and TCID 50 /mL was calculated by the Reed-Muench method. TaqMan RT-PCR: RNA copies upon plasma irradiation of SARS-CoV-2 were quantitatively determined by using the TaqMan RT-PCR method as described previously [31] , with slight modification. Briefly, the virus specimens before and after plasma irradiation were treated with Buffer AVL containing carrier RNA, and RNA was extracted according to the manufacturer's instructions for QIAmp Viral RNA Mini Kit (Qiagen, Hilden, Germany). TaqMan RT-PCR was performed with the N2 primer/probe set and BigDye Terminator v3.1 Cycle Sequencing Kit (Thermo Fischer Scientific) [31] using the QuantStudio 5 system (Thermo Fisher Scientific, Rockford, IL). Experiments using infectious MHV and SARS-CoV-2 were conducted in a biosafety level (BSL)-2 laboratory in The University of Tokyo and a BSL-3 laboratory in Okayama University of Science, respectively. We examined the inactivation of MHV after irradiation with the plasma streamer. The infectivity of the virus in the medium after 1, 2, and 3 hrs plasma irradiation was measured and expressed as pfu/mL (Table 1 ). In mock irradiation (control), the virus infectivity was determined to be 5.26  10 7 pfu/mL, 5.64  10 7 pfu/mL, 5.45  10 7 pfu/mL and 3.56  10 7 pfu/mL after 0, 1, 2 and 3 hrs, respectively. The virus infectivity upon plasma stream irradiation was 2.06  10 7 pfu/mL, 1.57  10 6 pfu/mL, and 5.42  10 4 pfu/mL after irradiation for 1, 2, and 3 hrs, respectively. When compared to the titers of corresponding times of the mock irradiation, the reductions in the virus titers upon plasma irradiation were 63.44%, 97.12%, and 99.85% after 1, 2, and 3 hrs irradiation, respectively. Inactivation of SARS-CoV-2 upon plasma irradiation: We examined the inactivation of SASR-CoV-2 after irradiation with the plasma streamer. The infectivity of the virus in the medium after 1, 2, and 3 hrs plasma irradiation was measured and expressed as TCID 50 /mL ( Table 2 ). In mock irradiation (control), the virus infectivity was 2.23  10 7 TCID 50 /mL, 2.17  10 7 TCID 50 /mL, 1.10  10 7 TCID 50 /mL, and 9.96  10 6 TCID 50 /mL after 0, 1, 2, and 3 hrs, respectively. The virus infectivity upon plasma stream irradiation was 1.05  10 6 TCID 50 /mL, 5.01  10 4 TCID 50 /mL, and 6.53  10 3 TCID 50 /mL after irradiation for 1, 2, and 3 hrs, respectively. When compared to the titers of the corresponding times of the mock irradiation, the reductions of the virus titers upon plasma irradiation were 95.17%, 99.54%, and 99.93% after 1, 2, and 3 hrs irradiation, respectively ( Table 2) . Effect of plasma irradiation on SARS-CoV-2 RNA copies of SARS-CoV-2 in the medium: We examined the effect of the number of RNA copies of SASR-CoV-2 after irradiation with the plasma streamer. The RNA of the virus in the medium after 1, 2, and 3 hrs of mock irradiation or plasma streamer irradiation in experiment 1 described above was extracted. The RNA was extracted from the plasma-irradiated and mock-irradiated viruses, and then the RNA was diluted 1,000-fold and subjected to TaqMan RT-PCR. In the mock irradiation, the numbers of virus RNA copies were calculated to be slightly reduced from those of the 0 hr treated virus of 1.1  10 11 RNA copies/mL to 1.0  10 11 RNA copies/mL, 9.1  10 10 RNA copies/mL, and 8.3  10 10 RNA copies/mL after mock irradiation for 1, 2 and 3 hrs, respectively. These reductions in the RNA copies/mL compared to the 0 hr treated virus were 8.3%, 17.2%, and 21.4% after 1, 2, and 3 hrs, respectively. The numbers of virus RNA copies upon plasma stream irradiation were 1.7  10 10 RNA copies/mL, 2.9  10 9 RNA copies/mL, and 6.9  10 8 RNA copies/mL after irradiation for 1, 2, and 3 hrs, respectively. When compared to the RNA copies of the corresponding times with the mock irradiation, the reductions of the virus RNA copies upon plasma irradiation were 82.94%, 96.79%, and 99.17% after 1, 2, and 3 hrs irradiation, respectively (Table 3 ). The stability of coronaviruses, including SARS-CoV-2, in different environmental conditions has been reported. A variety of commercially available disinfectants have been shown to be effective in inactivating SARS-CoV-2. However, the virus has been shown to be relatively stable in dried form, especially on stainless plastic surfaces and on the outer layers of masks, and infectious virus has been recovered after up to 4 to 7 days. The virus has been shown to be more stable in liquid form. Recently, studies on the inactivation of viruses, bacteria, and fungi by plasma irradiation have been reported. However, the mechanism of inactivation of microorganisms by plasma irradiation is not fully understood. Streamer discharge technology, which is a type of plasma discharge, produces various active substances by the collision of electrons moving at high speed in the plasma region with molecules such as nitrogen, oxygen, and water vapor in the atmosphere. For example, metastable nitrogen is considered to play an important role in various chained chemical reactions due to its high energy level and long life [32, 33] . Other studies have examined methods of exposing microorganisms directly to plasma [34] . According to these methods, high-energy electrons and short-lived active species, which are always present in large quantities in the plasma space, can be used. Therefore, the inactivation efficiency is increased, and the time required is shortened. However, this method is suitable for inactivating small areas only and is not suitable for processing large areas. Thus, it is not considered to inactivate microorganisms efficiently when their concentrations are low. In the present study, the inactivation rates of two coronaviruses, MHV and SARS-CoV-2, were virtually identical, indicating that the mechanisms of inactivation were the same. The decay rate of SARS-CoV-2 RNAs determined by RT-qPCR was slightly slower compared to that determined by SARS-CoV-2 infectivity. The RT-qPCR used in the present study detected 138 bases of the virus RNA; thus, the decay of the RNA measured by the RT-qPCR detected disruption of the virus RNA into fewer than 138 bases. However, virus infectivity will be lost even if there is only partial damage to the virus RNA with a size of 29,903 bases caused by plasma irradiation because an intact virus genome is necessary for the virus to replicate in the infected cells. In this regard, it is likely that SARS-CoV-2 inactivation based on RT-qPCR was underestimated compared to that based on the infectivity assay. Thus, the virus infectivity was reduced or lost by both a loss of virus protein functions and a disruption of viral RNAs. In the present study, various active molecules are generated in the plasma region of a streamer in space and exposed to a target away from the plasma. Although the time required for inactivation is slightly longer [34] , this form of application is suitable for inactivating large spaces and large amounts of air. In this regard, a quantitative measurement of such active molecules is a difficult technique that requires sophisticated equipment and skills. Further progress is necessary to clarify the mechanism of virus inactivation in the future. In conclusion, a plasma streamer was shown to be effective in inactivating the coronaviruses MHV and SARS-CoV-2. A Novel Coronavirus from Patients with Pneumonia in China A pneumonia outbreak associated with a new coronavirus of probable bat origin A new coronavirus associated with human respiratory disease in China The species Severe acute respiratory syndrome-related coronavirus: classifying 2019-nCoV and naming it SARS-CoV-2 Inactivation of Severe Acute Respiratory Syndrome Coronavirus 2 by WHO-Recommended Hand Rub Formulations and Alcohols Rapid In-Vitro Inactivation of Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) Using Povidone-Iodine Oral Antiseptic Rinse Enveloped Virus Inactivation on Personal Protective Equipment by Exposure to Ozone Far-UVC light (222 nm) efficiently and safely inactivates airborne human coronaviruses Influence of Different Inactivation Methods on Severe Acute Respiratory Syndrome Coronavirus 2 RNA Copy Number Vitro Efficacy of a Povidone-Iodine Nasal Antiseptic for Rapid Inactivation of SARS-CoV-2. JAMA Otolaryngol Head Neck Surg Rapid SARS-CoV-2 Inactivation by Commonly Available Chemicals on Inanimate Surfaces Hosp Infect. 2020. Epub 2020/09/08 Control Measures for SARS-CoV-2: A Review on Light-Based Inactivation of Single-Stranded RNA Viruses Susceptibility of SARS-CoV-2 to UV irradiation Inactivation times from 290 to 315 nm UVB in sunlight for SARS coronaviruses CoV and CoV-2 using OMI satellite data for the sunlit Earth Ultraviolet irradiation doses for coronavirus inactivation -review and analysis of coronavirus photoinactivation studies Sars-CoV-2 (COVID-19) inactivation capability of copper-coated touch surface fabricated by cold-spray technology Rapid inactivation of SARS-CoV-2 with deep-UV LED irradiation Inactivation of SARS-CoV-2 by commercially available alcohol-based hand sanitizers A review on presence, survival, disinfection/removal methods of coronavirus in wastewater and progress of wastewaterbased epidemiology Evaluation of Chemical Protocols for Inactivating SARS-CoV-2 Infectious Samples Epub 2020/06/08 SARS-CoV-2 Viral Inactivation Using Low Dose Povidone-Iodine Oral Rinse-Immediate Application for the Prosthodontic Practice Transmission of COVID-19 virus by droplets and aerosols: A critical review on the unresolved dichotomy Transmission of SARS CoV-2: A Review of Viral, Host, and Environmental Factors Factors affecting stability and infectivity of SARS-CoV-2 Stability of SARS-CoV-2 in different environmental conditions Aerosol and Surface Stability of SARS-CoV-2 as Compared with SARS-CoV-1 Decomposition of volatile organic compounds using corona discharge plasma technology Decomposition of toluene by streamer corona discharge with catalyst Assessment of Real-Time RT-PCR Kits for SARS-CoV-2 Detection Evaluated Chemical Kinetics Data for Reactions of N(2D) Measurement of N2A3Σu +metastable in N2 pulsed positive corona discharge with trace amounts of additives Epub 2019/10/21