key: cord-0938724-5ohrtyyq authors: Li, Jie; Fink, James B.; Augustynovich, Ashley E.; Mirza, Sara; Kallet, Richard H.; Dhand, Rajiv title: Effects of Inhaled Epoprostenol and Prone Positioning in Intubated Coronavirus Disease 2019 Patients With Refractory Hypoxemia date: 2020-12-16 journal: Crit Care Explor DOI: 10.1097/cce.0000000000000307 sha: 221059e94dfa93fc58e6d9ceb8618da4ec782aad doc_id: 938724 cord_uid: 5ohrtyyq OBJECTIVES: To evaluate the effects of inhaled epoprostenol and prone positioning, individually and in combination in mechanically ventilated patients with coronavirus disease 2019 and refractory hypoxemia. DESIGN: Retrospective study. SETTING: Academic hospital adult ICUs. PATIENTS: Adult patients who received inhaled epoprostenol and prone positioning during invasive ventilation were enrolled. Patients were excluded if inhaled epoprostenol was initiated: 1) at an outside hospital, 2) after prone positioning was terminated, 3) during extracorporeal membrane oxygenation or cardiopulmonary resuscitation, and 4) with Pao(2)/Fio(2) greater than 150 mm Hg. INTERVENTIONS: Inhaled epoprostenol and prone positioning. RESULTS: Of the 43 eligible patients, 22 and seven received prone positioning and inhaled epoprostenol alone, respectively, prior to their use in combination, Pao(2)/Fio(2) was not different pre- and post-prone positioning or inhaled epoprostenol individually (89.1 [30.6] vs 97.6 [30.2] mm Hg; p = 0.393) but improved after the combined use of inhaled epoprostenol and prone positioning (84.0 [25.6] vs 124.7 [62.7] mm Hg; p < 0.001). While inhaled epoprostenol and prone positioning were instituted simultaneously in 14 patients, Pao(2)/Fio(2) was significantly improved (78.9 [27.0] vs 150.2 [56.2] mm Hg, p = 0.005) with the combination. Twenty-seven patients (63%) had greater than 20% improvement in oxygenation with the combination of inhaled epoprostenol and prone positioning, and responders had lower mortality than nonresponders (52 vs 81%; p = 0.025). CONCLUSIONS: In critically ill, mechanically ventilated patients with coronavirus disease 2019 who had refractory hypoxemia, oxygenation improved to a greater extent with combined use of inhaled epoprostenol and prone positioning than with each treatment individually. A higher proportion of responders to combined inhaled epoprostenol and prone positioning survived compared with nonresponders. These findings need to be validated by randomized, prospective clinical trials. mm Hg, p = 0.005) with the combination. Twenty-seven patients (63%) had greater than 20% improvement in oxygenation with the combination of inhaled epoprostenol and prone positioning, and responders had lower mortality than nonresponders (52 vs 81%; p = 0.025). Conclusions: In critically ill, mechanically ventilated patients with coronavirus disease 2019 who had refractory hypoxemia, oxygenation improved to a greater extent with combined use of inhaled epoprostenol and prone positioning than with each treatment individually. A higher proportion of responders to combined inhaled epoprostenol and prone positioning survived compared with nonresponders. These findings need to be validated by randomized, prospective clinical trials. Key Words: coronavirus disease 2019; hypoxemia; inhaled epoprostenol; prone positioning I n the U.K. national ICU audit, 72.7% of hospitalized patients with coronavirus disease 2019 (COVID-19) required advanced respiratory support (1) . Management of COVID-19 remains largely supportive. Epoprostenol is a naturally occurring prostaglandin that relaxes vascular smooth muscle and also provides anti-inflammatory effects (2, 3) . Inhaled epoprostenol (iEPO) has been used off-label for over 2 decades to reduce pulmonary artery pressure and improve oxygenation in critically ill patients (2) (3) (4) (5) . Hypoxemia in COVID-19 patients is mainly caused by ventilation-perfusion mismatch (6) , which might be improved by inhalation of a pulmonary vasodilator. However, due to concerns of virus transmission by aerosol dispersion during nebulization (7) , iEPO has been limited to rescue therapy for patients with COVID-19, especially during the early phase of the pandemic. In this report, we describe our preliminary experience with iEPO in mechanically ventilated COVID-19 patients with refractory hypoxemia (defined as Pao 2 /Fio 2 ≤ 150 mm Hg) while on optimal ventilator settings according to the high positive end-expiratory pressure (PEEP) low-Fio 2 acute respiratory distress syndrome (ARDS) network protocol (8) . Prior to the COVID-19 pandemic, prone positioning (PP) was shown to improve oxygenation and reduce 28-and 90-day mortality in intubated patients with severe ARDS (9, 10) . Thus, PP has been recommended by the Surviving Sepsis Campaign COVID-19 subcommittee (11) and broadly used as an early intervention for intubated COVID-19 patients with refractory hypoxemia (8, (12) (13) (14) (15) (16) (17) . In this preliminary study, we compared the effects of PP and iEPO both individually and in combination, on oxygenation in COVID-19 patients with refractory hypoxemia. After approval by the Institutional Review Board (20050405-IRB01) at the Rush University Medical Center, a retrospective study was implemented to screen consecutive patients with laboratory confirmed COVID-19 admitted to adult ICUs between March 18, 2020, and May 31, 2020. Adult patients who received iEPO and PP during invasive ventilation were enrolled. Patients were excluded if iEPO was initiated at an outside hospital or after PP was terminated, if iEPO was employed during extracorporeal membrane oxygenation (ECMO) or cardiopulmonary resuscitation, or if iEPO was initiated with Pao 2 /Fio 2 greater than 150 mm Hg. Epoprostenol (Veletri, Actelion Pharmaceuticals US, San Francisco, CA) was prepared in a 50-mL syringe and delivered via continuous nebulization using a vibrating mesh nebulizer (Aeroneb Solo; Aerogen, Galway, Ireland) and a syringe pump, with the nebulizer placed at the inlet of the humidifier (4). iEPO was initiated at 50 ng/kg/min of patient's predicted body weight, and the dose was maintained for a minimum of 24 hours after initiation. iEPO weaning was determined by the treating physicians and was titrated down by 10 ng/kg/min every 30-60 minutes if the patient's oxygenation remained stable. PP was initiated if patients' Pao 2 /Fio 2 ratio could not be maintained greater than or equal to 150 mm Hg with PEEP set greater than or equal to 10 cm H 2 O and Fio 2 greater than or equal to 0.6 (9). The prone position was maintained for at least 16 hours (12). The primary outcome was to compare oxygenation with PP or iEPO individually with combined use of PP and iEPO. Patient's position (supine or prone) at which iEPO was initiated was collected, and the number of sessions for PP prior to and after iEPO initiation was also recorded. The ratio of Pao 2 /Fio 2 was compared within 2 hours pre and post either iEPO or PP or in combination. If Pao 2 was not available, Spo 2 was used as a substitute only in subjects with Spo 2 less than or equal to 97%. A greater than 20% improvement of Pao 2 /Fio 2 ratio (or Spo 2 /Fio 2 if Pao 2 /Fio 2 was not available) was considered as a positive response. Kolmogorov-Smirnov was used to test normality of distribution for considered variables. Continuous variables were expressed as mean (sd) or median (interquartile range [IQR]), depending on the normality of distribution. Paired t test or Wilcoxon sign-rank test was used to compare pre-and post responses with iEPO or PP and changes from supine to iEPO + PP, whereas t test or Mann-Whitney test was used to compare the incremental changes between the responder and nonresponder groups and differences in categorical variables were assessed with the chi-square test. A p value of less than 0.05 was considered statistically significant for all tests. Data analysis was conducted with the SPSS statistical software (SPSS 26.0; SPSS, Chicago, IL). From March 18, 2020, to May 31, 2020, 336 adult patients with confirmed COVID-19 were admitted to our ICUs. Among the 234 intubated patients, 57 patients received iEPO and PP during invasive ventilation, 14 patients were excluded for the following reasons: 1) iEPO was initiated after PP was terminated (n = 8), 2) iEPO was used during ECMO (n = 2), 3) iEPO was used during cardiopulmonary resuscitation (n = 1), 4) iEPO was initiated at an outside hospital (n = 1), and 5) iEPO was initiated with Pao 2 /Fio 2 greater than 150 mm Hg (n = 2) (Fig. 1) . In total, 43 patients (27 male) were eligible, with a mean (sd) age 55.1 (13.8) years and the predominant ethnicities were Hispanic/Latino (54%) and African American (33%). On the day of iEPO initiation, patients' median (IQR) Sequential Organ Failure Assessment score was 9 (8) (9) (10) (11) , and the duration from COVID-19 confirmation was 9 days (4-14 d), whereas mechanical ventilation had been used for 68 hours Because of the retrospective nature of this study, it became apparent that patients fell into two categories: the majority (29) received therapy in an additive manner (either PP followed by the addition of iEPO or vice versa), whereas 14 patients started on PP and iEPO at the same time. The response to the approaches of adding one therapy to the other is described first, followed by combined therapy group. Table 1) . Among the nine responders to PP, four (44%) showed continued improvements in oxygenation to iEPO with PP. Among the 13 nonresponders to PP, four (31%) responded to iEPO with PP (Fig. 1) . Regarding the relationship between the initiation of iEPO to PP, six of the 22 patients used iEPO during their first PP session, four (67%) of whom responded to PP, and three (75%) continued responding to iEPO with PP, whereas of the two patients (50%) who did not respond to initial PP responded to the combination of iEPO with PP. Seven patients had iEPO initiated in supine position. Patients' oxygenation (Pao 2 /Fio 2 or Spo 2 /Fio 2 ) was not significantly different pre-versus post-iEPO (Supplemental Table 1 p = 0.046). Among the seven patients, two responded to iEPO, one of whom continued responding to PP with iEPO, whereas among the remaining five patients who did not respond to iEPO, four responded to the combination of PP with iEPO (Fig. 1) . To summarize, for the aforementioned 29 patients who received PP (n = 22) or iEPO (n = 7) individually prior to the combination, Pao 2 /Fio 2 was not significantly different either pre-versus post-iEPO or PP (89. 1 Table 2) . Of the 14 patients, 12 (86%) responded to the combined use of iEPO and PP (Fig. 1) . Among the 11 patients who had never been proned before, 10 (91%) responded to iEPO with PP. Taking all patients into account, compared with patients' Pao 2 / Fio 2 under supine position, the combined use of iEPO and PP significantly improved Pao 2 /Fio 2 (84.0 [25.6] vs 124.7 [62.7] mm Hg; n = 36; p < 0.001) (Fig. 3) . Compared with patients' oxygenation (Pao 2 /Fio 2 or Spo 2 /Fio 2 if Pao 2 /Fio 2 was not available) in supine position, 27 patients had positive responses (greater than 20% improvement) with the combination of iEPO with PP. Compared with the nonresponders, responders had a trend of fewer PP sessions prior to the combined use of iEPO and PP (1 [0-4] vs 3 [1.3-3.8]; p = 0.054), particularly higher percentage of patients who had never been placed on PP before (44 vs 6%; p = 0.022). Responders had lower mortality than nonresponders (52 vs 81%; p = 0.025) ( Table 3) . In this single-center cohort study, we found that the combined use of iEPO with PP improved oxygenation in intubated COVID-19 patients with refractory hypoxemia, including some patients who did not respond to PP or iEPO individually. To our knowledge, this is the first report on the effects of combining iEPO with PP, which is consistent with other studies on the effects of combining PP with inhaled nitric oxide in patients with ARDS (10, 18) . The mechanism by which oxygenation improves with PP and iEPO might be due to a reduction in ventilation/perfusion mismatch, via the combined benefits of dilating pulmonary vessels in the dorsal areas of the lung with improved ventilation of those areas (10) . In ARDS, the iEPO response rate is approximately 60% but the response is lower in patients with sepsis (3) because of endothelial dysfunction and dysregulation of nitric oxide and prostacyclin (19) . Similarly, COVID-19 also induces both pulmonary and systemic endothelial dysfunction (6) , thereby making it difficult to predict iEPO responsiveness. Our previous cohort study on intubated COVID-19 patients found that over 70% of them responded to the first PP session, whereas the response rates decreased starting from the second PP session (12) . In this study, more than 50% of the enrolled patients had previously been placed on PP more than once on maximum ventilator settings (prior to enrollment), which might explain the lower response rate to iEPO and PP. Compared with the nonresponders in the second and third PP sessions, the responders had lower rates of treatment failure, which was defined as death or escalation to ECMO therapy (12) . We also found the responders had lower mortality. The high mortality rate even among the responders in this study might be explained by the higher severity of patients and the use of iEPO as the last resort. Likewise, Garcia et al (16) reported the survival rate of 14.3% in their cohort with veno-venous-ECMO for COVID- 19 patients that underwent PP, whereas Shelhamer et al (17) reported mortality of 77.4% in the PP group and 83.9% in the control group that did not undergo PP. The authors explained that the high mortality was contributed by the severe acuity of patients receiving those treatments (PP or ECMO) as rescue therapy. In our study, 14 patients who first received iEPO and PP at the same time had higher response rate (86%) to iEPO with PP, however whether or not earlier use of iEPO and PP in combination could provide additional benefits in treating refractory hypoxemia in mechanically ventilated patients with COVID-19 requires further investigation. Our study is limited by the lack of a control group and a small sample size. However, our study found improvement in oxygenation when PP was combined with iEPO as rescue therapy in critically ill patients. Our findings suggest that combination has benefit but does not directly address whether patients with an oxygen response to iEPO/iNO might further benefit from combining PP. The combination of PP and iEPO should be considered as supportive therapy for refractory hypoxemia in mechanically ventilated patients in institutions where ECMO is not available or prior to escalation to ECMO therapy. Our findings suggest that nonresponders to the combined use of iEPO and PP should be prioritized as ECMO candidates. Randomized clinical trials are needed to confirm these findings in COVID-19 and non-COVID-19 patients with refractory hypoxemia and to investigate further if it improves survival in such critically ill patients. Seven patients (16%) did not have pre-and posttreatment Pao 2 /Fio 2 , so we used Spo 2 /Fio 2 (only Spo 2 < 97% were chosen) as an alternative to ensure better correlation with Pao 2 /Fio 2 (20) . However, use of Spo 2 /Fio 2 could result in discrepant findings. Thus, Pao 2 /Fio 2 should be preferred as the parameter to assess response to refractory hypoxemia with the combination of iEPO and PP in future studies. In mechanically ventilated patients with COVID-19 who had refractory hypoxemia, combined use of iEPO and PP improved oxygenation to a greater extent than with each treatment individually. Responders to combined modalities had lower mortality than nonresponders. Aerosolized vasodilators for the treatment of pulmonary hypertension in cardiac surgical patients: A systematic review and meta-analysis Severity of hypoxemia and other factors that influence the response to aerosolized prostacyclin in ARDS The clinical impact of flow titration on epoprostenol delivery via high flow nasal cannula for ICU patients with pulmonary hypertension or right ventricular dysfunction: A retrospective cohort comparison study The use of inhaled prostaglandins in patients with ARDS: A systematic review and meta-analysis Novel insights on the pulmonary vascular consequences of COVID-19 Coughs and sneezes: Their role in transmission of respiratory viral infections, including SARS-CoV-2 The ARDS Clinical Trials Network: Higher versus lower positive endexpiratory pressures in patients with the acute respiratory distress syndrome PROSEVA Study Group: Prone positioning in severe acute respiratory distress syndrome A comprehensive review of prone position in ARDS Surviving sepsis campaign: Guidelines on the management of critically ill adults with coronavirus disease 2019 (COVID-19) Prone positioning for patients intubated for severe acute respiratory distress syndrome (ARDS) secondary to COVID-19: A cohort study Respiratory pathophysiology of mechanically ventilated patients with COVID-19: A cohort study Lung recruitability in COVID-19-associated acute respiratory distress syndrome: A single-center observational study Prolonged prone position ventilation for SARS-CoV-2 patients is feasible and effective Lille Intensive Care COVID-19 Group: Prone positioning under VV-ECMO in SARS-CoV-2-induced acute respiratory distress syndrome Prone positioning in moderate to severe acute respiratory distress syndrome due to COVID-19: A cohort study and analysis of physiology. Res Sq. Preprint posted online Additive beneficial effects of the prone position, nitric oxide, and almitrine bismesylate on gas exchange and oxygen transport in acute respiratory distress syndrome Endothelial dysfunction in sepsis National Institutes of Health, National Heart, Lung, and Blood Institute ARDS Network: Comparison of the SpO2/FIO2 ratio and the PaO2/FIO2 ratio in patients with acute lung injury or ARDS We thank all the respiratory therapists in Respiratory Care Department in the Rush University Medical Center for their dedicated and diligent work during coronavirus disease 2019 pandemic. We also thank Mr. Rongshou Zheng, MPH, for consultancy in data analysis.