key: cord-0952181-rs8b1iut authors: Rauch, Simon; van Veelen, Michiel Jan; Oberhammer, Rosmarie; Dal Cappello, Tomas; Roveri, Giulia; Gruber, Elisabeth; Strapazzon, Giacomo title: Effect of Wearing Personal Protective Equipment (PPE) on CPR Quality in Times of the COVID-19 Pandemic—A Simulation, Randomised Crossover Trial date: 2021-04-16 journal: J Clin Med DOI: 10.3390/jcm10081728 sha: 257b47249138674a952cfb37fa3bed3eae92aa09 doc_id: 952181 cord_uid: rs8b1iut Cardiopulmonary resuscitation (CPR) is considered an aerosol-generating procedure. Consequently, COVID-19 resuscitation guidelines recommend the use of personal protective equipment (PPE) during resuscitation. In this simulation of randomised crossover trials, we investigated the influence of PPE on the quality of chest compressions (CCs). Thirty-four emergency medical service BLS-providers performed two 20 min CPR sequences (five 2 min cycles alternated by 2 min of rest) on manikins, once with and once without PPE, in a randomised order. The PPE was composed of a filtering facepiece 3 FFP3 mask, safety glasses, gloves and a long-sleeved gown. The primary outcome was defined as the difference between compression depth with and without PPE; secondary outcomes were defined as differences in CC rate, release and the number of effective CCs. The participants graded fatigue and performance, while generalised estimating equations (GEE) were used to analyse data. There was no significant difference in CC quality between sequences without and with PPE regarding depth (mean depth 54 ± 5 vs. 54 ± 6 mm respectively), rate (mean rate 119 ± 9 and 118 ± 6 compressions per minute), release (mean release 2 ± 2 vs. 2 ± 2 mm) and the number of effective CCs (43 ± 18 vs. 45 ± 17). The participants appraised higher fatigue when equipped with PPE in comparison to when equipped without PPE (p < 0.001), and lower performance was appraised when equipped with PPE in comparison to when equipped without PPE (p = 0.031). There is no negative effect of wearing PPE on the quality of CCs during CPR in comparison to not wearing PPE. The Coronavirus disease 2019 (COVID-19) pandemic is causing significant disruptions in healthcare systems worldwide, with about a hundred million confirmed cases and nearly 2.4 million deaths recorded as of mid-February 2020 [1]. Sultanian et al. have recently reported that 20.9% of patients in out of hospital cardiac arrest (OHCA) cases in Sweden have severe acute respiratory syndrome coronavirus type 2 (SARS-CoV-2) infections [2] . It is impossible for prehospital healthcare providers at the scene of an OHCA to rule out a SARS-CoV2-infection without delay. Cardiopulmonary resuscitation (CPR) is considered an aerosol-generating procedure [3] , and unprotected exposure to droplets and airborne particles from an infected patient constitutes an infection risk. Despite a lack of direct evidence, the International Liaison Committee on Resuscitation (ILCOR) recommends that healthcare providers should therefore use personal protective equipment (PPE) for aerosolgenerating procedures during resuscitation [4] . Currently, the European Resuscitation Council (ERC) recommends PPE for airborne precaution to consist of gloves, a long-sleeved gown, a filtering facepiece 3 (FFP3) or N99 mask/respirator (FFP2 or N95 if FFP3 is not available), and eye and face protection (full-face shield/visor, polycarbonate safety glasses or equivalent equipment) [5] . The act of performing adequate CCs is a strenuous activity, and one's exercise capacity could be a limiting factor [6] . The effect of wearing face masks on physical exercise capacity due to increased breathing resistance is currently under debate [7] . There are little data published on the effect of PPE on the effectiveness or quality of CPR. In this trial, we investigate the effect of wearing PPE (including an FFP3 face mask) on the quality of CCs during CPR performed by prehospital healthcare providers. We hypothesize that the quality of CCs delivered is not affected by wearing PPE. The study was designed as a simulation randomised crossover trial and ran from 29 September to 14 October 2020 in Bolzano, Merano and Brunico (South Tyrol, Italy). The Ethics Committee review board of Bolzano, Italy, approved the study (protocol number 100-2020), and the study is registered on ClinicalTrials.gov (Protocol Record NCT04548934). The study was conducted in accordance with the principles of the Declaration of Helsinki. Study participants were providers recruited from the prehospital emergency medical service organisation 'Croce Bianca' (South Tyrol, Italy). The inclusion criteria for study participants are as follows: participants must be aged between 18 and 65 years old, must have a valid certificate in BLS, must have no COVID-19 symptoms in the last four weeks before the test, must not be tested positive for SARS-CoV2, must have no quarantine or unprotected contact with COVID-19 patients in the last four weeks, must have a body temperature less than 37.5 • C on the test day and must have obtained written informed consent with respect to the study. Before the test, each participant practiced CCs on a manikin and was given visual and verbal feedback on the quality of their CCs. The participants were blinded neither to the intervention nor to the study purpose. Each study participant performed two CPR sequences on a manikin, once with PPE and once without PPE in a randomised order. We used block randomization in order to guarantee that half of the participants started the sequences with PPE and that the other half of the participants started without PPE. Each sequence lasted 20 min and was composed of five cycles consisting of two minutes of CCs alternated by two minutes of no CCs (break), simulating a changeover, as is recommended by the current ERC guidelines [8] . Between the two CPR sequences (i.e., with and without PPE) a break of one hour for recovery was given. The PPE was composed of an FFP3 mask (Valmy Cyrano ® FFP3, Mably, France), safety glasses, gloves and a long-sleeved gown. During both CPR sequences, the quality of CCs was measured using the manikin (Laerdal Resusci Anne QCPR, Stavanger, Norway), which was fitted with a standard compression spring that was connected to a tablet PC (Laerdal Simpad PLUS, Stavanger, Norway). The indicators of CC quality were comprised of compression depth, rate, release and the number of effective CCs, where compressions with a depth of greater than 50 mm at the correct position (mid-chest) were counted as effective. Directly after each sequence, participants were asked by trained members of the study team to subjectively grade fatigue and performance using an eleven point (from 0 to 10) numeric rating scale (NRS), where 0 corresponded to minimal fatigue or performance and 10 corresponded to maximal fatigue or performance. The difference between compression depths with and without PPE was defined as the primary outcome. Secondary outcomes were defined as differences in CC rate, release and the number of effective CCs. Additional outcome measures included the influence of gender, body weight, PPE sequence order and cycle number on CC quality. The subjective fatigue and participant performance evaluations, with and without PPE, were defined as tertiary study outcomes. According to the crossover design, which had an expected mean difference of 5 mm and a standard deviation of the difference of 9 mm (effect size 0.55), a sample size of 28 matched pairs was calculated as sufficient to evaluate the primary outcome at a significance level of 0.05 (two-sided) with 80% power [9] . Each 2 min cycle of CCs was divided into four 30 s timepoints, and the average of CC depth, rate, and release and the number of effective CCs per timepoint were considered dependent variables. To take into account the repeated measures of each participant (four 30 s timepoints for each of the five cycles), generalised estimating equations (GEE) were performed for each dependent variable to analyse whether the following factors had an effect: PPE (with or without), cycle number, timepoint, PPE sequence order (first or second), weight (two groups considering the median of 80 kg as the cut-off), gender, the interactions of timepoint and cycle number with PPE, gender and weight, and the interaction of PPE with gender. The Wilcoxon signed rank test was performed to compare the participant's subjective fatigue and performance when using or not using PPE, and Pearson correlation was implemented to correlate subjective fatigue and performance with the compression parameters. The Holm-Bonferroni method was used to correct p-values for multiple comparisons. SPSS version 26 (IBM Corp., Armonk, NY, USA) was used for statistical analysis, and p < 0.05 (twosided) was considered statistically significant. The values are reported as mean ± standard deviation, except for estimates of the GEE as the mean (95% confidence interval). Thirty-four participants were consecutively recruited, and all of them met the inclusion criteria. Participants' baseline characteristics are shown in Table 1 . All of the participants completed two 20 min sequences of CCs with and without PPE in a randomised sequence order. Due to technical problems, CC quality could not be recorded in three sequences (this consisted of two sequences with PPE and one sequence without PPE; the data are considered missing completely at random and discarded from the analysis); therefore, a total of 65 sessions were included in the analysis. The mean compression depth, release, rate, and number of effective CCs with and without PPE is shown in Table 2 . Evolutions of the CC quality parameters per 2 min cycle and per 30 s timepoint during a cycle are illustrated in Figures 1 and 2 . We found no effect of wearing PPE with respect to compression depth, release, rate and number of effective CCs ( Table 3) . Independent of PPE, the estimated means showed deeper compression during the first cycle (54 (52-56) mm) in comparison to the second (53 (51-55) mm, p = 0.001) and fifth cycles (53 (51-55) mm, p = 0.011), and an increasing rate from the first to the fifth cycles (117 (115-119) vs. 119 (117-122) compressions per minute, p < 0.001). In the 30 s timepoint analysis, the estimated means of compression depth, rate and number of effective compressions showed a decreasing trend that was not dependent on PPE: comparing the first 30 s with the last 30 s, depth decreased from 55 (54-57) mm to 52 (50-54) mm (p < 0.001), the rate decreased from 120 (117-122) to 117 (115-120) compressions per minute (p < 0.001) and the number of effective CCs decreased from 50 (45-56) to 37 (31-44) (p < 0.001). The effect of wearing PPE on compression parameters was not different between females and males (Table 3) . PPE-personal protective equipment; CCs-chest compressions. * An asterisk between two factors denotes an interaction. # The specified distribution and link function were normal and identified for the chest compression depth and rate, Gamma and the logarithm for chest compression release, and Poisson and the logarithm for the number of effective chest compressions; the working correlation matrix was chosen by means of the Quasi-Likelihood under Independence Model Criterion (QIC) among 1-dependent, independent, unstructured and first-order autoregression (AR(1)) and was independent for chest compression depth, rate and release and AR(1) for the number of effective chest compressions. † Not calculated because of computational issues. The participants appraised higher fatigue with PPE in comparison to without PPE (6.7 ± 1.8 vs. 5.0 ± 2.1 NRS, p < 0.001) and lower performance with PPE in comparison to without PPE (6.8 ± 1.4 vs. 7.3 ± 1.1 NRS, p = 0.031). Subjective fatigue and performance were not correlated with compression parameters (Table 4 ). We found no effect of wearing PPE (including an FFP3 mask) on CC quality during manikin CPR. We found a statistically significant difference in CC depth and rate over time, both during the entire 20 min sequence and during the single two-minute cycle. These differences were, however, similar for both sequences (with and without PPE) and presumably of no clinical significance, as virtually all delivered compressions were within the limits of resuscitation guidelines. Even though the participants experienced increased subjective fatigue and decreased subjective performance while wearing PPE, this did not reflect on the objective physical performance during the delivery of CCs. The perceived exertion of performance and reduced performance could be due to increased airflow resistance while breathing through an FFP2 or FFP3 mask [10] . Most studies that have investigated the effect of mask-wearing during exercise on physiological changes and subjective symptoms found only a minor physiological burden but relevant subjective disturbances [11] [12] [13] . This is consistent with our findings. Moreover, earlier studies assessing subjective performance during CCs confirm the inability of participants to self-estimate the adequate quality of CCs [14, 15] . Our findings contradict a systematic review that included five trials and that subsequently concluded that the use of PPE compromises the quality of CCs during CPR [16] . However, this review has several limitations and its applicability to the current COVID-19 pandemic seems to be questionable. For instance, only one out of the five included studies was performed during the COVID-19 pandemic and, more importantly, in four out of the five trials, cumbersome Level B or level C HAZMAT full-face air purification devices were used. Moreover, only one trial had a clinically relevant difference regarding CC rate and depth between the PPE and no-PPE arm [16] . However, in this trial depth was inadequate both in the control (no-PPE) arm as well as in the intervention (PPE) arm (49.3 ± 6.9 mm versus 42.5 ± 6.8 mm, respectively) and the statistically significant difference in the mean CC rate was of dubious clinical relevance (105.4 ± 8.3 versus 98.1 ± 8.9 compressions per minute in the control arm and in the PPE arm, respectively) [17] . In a recent manikin study by Malysz et al., an insufficient compression depth (median 40 mm) was found during a 2 min cycle of CCs on a manikin while wearing PPE for aerosol-generating procedures [18] . Based on their findings, the authors argued that the CPR algorithm should be changed by reducing the duration of the CPR cycle for one rescuer from the current 2 min cycles to 1 min cycles when performing manual CCs. However, the trial did not have a control group (without PPE), and this renders the authors' conclusions questionable. Kienbacher et al. in their randomised controlled non-inferiority triple-crossover manikin study did not report any difference regarding the quality of CCs while wearing or not wearing PPE with an FFP2 mask, which is similar to our findings [19] . Moreover, the providers in their trial reported a subjectively higher physical strain, but physical exhaustion did not correlate well with the quality of CPR. To our knowledge, our study is the first study comparing the quality of CCs while wearing an FFP3 mask. Our findings confirm that the use of PPE as recommended by the current COVID-19 resuscitation guidelines [5] , even when wearing an FFP3 mask, does not alter CC quality during simulated manikin CPR compared to when not wearing PPE. Our study has some limitations. In the first place, it is a manikin study with all its associated limitations. In the second place, we did not take into account the time needed to equip the PPE. Donning PPE can cause a significant delay in CPR initiation, which has associated negative patient outcomes. Finally, vision and communication between healthcare providers during CPR can be impaired by PPE, which could harm resuscitation outcomes [4, 20] . Thus, high-fidelity simulation training with PPE should be performed regularly to optimise resuscitation outcomes. There is no negative effect in wearing PPE for airborne disease transmission precaution on the quality of CCs delivered during CPR compared to when not wearing PPE. The results could help support evidence-based guidelines for resuscitation with respect to the particular circumstances of potential airborne disease transmission. However, wearing PPE during CPR leads to increased subjective fatigue and decreased subjective performance. The publication fee was covered by Italian Resuscitation Council with funds for dissemination within the "iProcureSecurity" H2020 project (Grant Agreement No 833291). The study was conducted according to the guidelines of the Declaration of Helsinki and was approved by the Institutional Review Board of Bolzano, Italy (protocol number 100-2020, approved on 26 August 2020). Informed Consent Statement: Informed consent was obtained from all subjects involved in the study. The data presented in this study are available upon request from the corresponding author. WHO. Coronavirus Disease (COVID-19) Dashboard. Available online Cardiac arrest in COVID-19: Characteristics and outcomes of in-and out-of-hospital cardiac arrest. A report from the Swedish registry for cardiopulmonary resuscitation Transmission of SARS-CoV-2: Implications for Infection Prevention Precautions COVID-19 in cardiac arrest and infection risk to rescuers: A systematic review European resuscitation council COVID-19 guidelines executive summary Effect of rescuer fatigue on performance of continuous external chest compressions over 3 min Face masks and the cardiorespiratory response to physical activity in health and disease European resuscitation council guidelines for resuscitation 2015: Section 2. Adult basic life support and automated external defibrillation Evaluation of the quality of cardiopulmonary resuscitation according to vehicle driving pattern, using a virtual reality ambulance driving system: A prospective, cross-over, randomised study Objective assessment of increase in breathing resistance of N95 respirators on human subjects Wearing an N95 respiratory mask: An unintended exercise benefit? Return to training in the COVID-19 era: The physiological effects of face masks during exercise. Scand Physiologic and other effects and compliance with long-term respirator use among medical intensive care unit nurses Decay in quality of closed-chest compressions over time The effect of rescuer fatigue on the quality of chest compressions Impact of personal protective equipment on the effectiveness of chest compression-A systematic review and meta-analysis Chest compression with personal protective equipment during cardiopulmonary resuscitation: A randomized crossover simulation study Resuscitation of the patient with suspected/confirmed COVID-19 when wearing personal protective equipment: A randomized multicenter crossover simulation trial The use of personal protection equipment does not impair the quality of cardiopulmonary resuscitation: A prospective triple-cross over randomised controlled non-inferiority trial Resuscitation during the COVID-19 pandemic: Lessons learnt from high-fidelity simulation We thank the Croce Bianca (Bolzano, Merano and Brunico, Italy) volunteers for participating, especially Lukas Innerhofer and Lorenz Lintner for their organisational and logistical support. The authors declare no conflict of interest.