key: cord-0969040-qy7epxue authors: McSoley, Matthew J.; Rosenfeld, Eldar; Grajewski, Alana; Chang, Ta Chen title: The effect of photographic light brightness on cup to disc ratio grading date: 2021-12-13 journal: BMC Ophthalmol DOI: 10.1186/s12886-021-02209-6 sha: 1094f131de81afe59270c2d465dc34293d4b2957 doc_id: 969040 cord_uid: qy7epxue BACKGROUND: Digital optic disc photographs are integral to remote telehealth ophthalmology, yet no quality control standards exist for the brightness setting of the images. This study evaluated the relationship between brightness setting and cup/disc ratio (c/d) grading among glaucoma specialists. METHODS: Optic disc photographs obtained during routine examinations under anesthesia were collected to construct an image library. For each optic disc, photographs were obtained at 3 light intensity settings: dark, medium, and bright. From the image library, photograph triads (dark, medium and bright) of 50 eyes (50 patients) were used to construct the study set. Nine glaucoma specialists evaluated the c/d of the study set photographs in randomized order. The relationships between the brightness levels and the c/d grading as well as graders’ years in practice and variability were evaluated. RESULTS: The c/d were graded as significantly larger in bright photographs when compared to photographs taken at the medium light intensity (0.53 vs 0.48, P < 0.001) as well as those taken at the dark setting (0.47, P < 0.001). In addition, no relationship was found between ophthalmologists’ years in practice and the variability of their c/d grading (P = 0.76). CONCLUSION: Image brightness affects c/d grading of nonstereoscopic disc photographs. The brighter intensity is associated with larger c/d grading. Photograph brightness may be an important factor to consider when evaluating digital disc photographs. The use of color disc photography as a glaucoma screening tool was first championed by Lichter et al. in 1976 [1] , and several subsequent studies comparing color disc photography to clinical examination has shown photographs to have excellent specificity and modest sensitivity in detecting glaucoma [2] . The 2019 SARS-CoV-2 pandemic (COVID-19) has galvanized renewed interest and efforts for telehealth ophthalmologic care. Nonstereoscopic disc photography is an imaging modality that is directly accessible to the patients by adapting smart phone devices [3] , and thus are integral in remote telehealth ophthalmology care [4] . In particular, digital optic disc images will be central to remote glaucoma screening, evaluation, and management [5] . Currently, there are no standardized quality control protocols for obtaining digital optic disc images, with the light intensity setting being one of the variables that can change based on the device and the photographer. The effect of this variability on the assessment of the optic disc configurations is unknown [6] . In this study, we evaluated the effect of light brightness setting on c/d grading of nonstereoscopic disc images among glaucoma specialists with varying levels of experience. An image library was constructed retrospectively using nonstereoscopic digital optic disc photographs obtained from pediatric patients during examinations under anesthesia using the RetCam (Natus Medical, Inc. Pleasanton, CA, USA). These patients all have unilateral or bilateral ocular pathologies, including childhood glaucoma. Each optic disc (healthy and otherwise) was imaged at 3 different brightness settings: dark (RetCam light brightness setting 20), medium (brightness setting 25), and bright (brightness setting 30), with the ambient light of the room kept the same for each capture. From this library, the images from 50 eyes of 50 children were included in the study, with 3 photographs per eye at dark, medium and bright brightness levels (total 150 separate images). Only photograph triads with clearly visible third-order vessels were included. Prior to the examinations under anesthesia, informed consent was provided by all parents or legal guardians to have any images obtained used for research and educational purposes. Example images of the same eye taken at each of the three light brightness settings are show in Fig. 1 . The set of 150 photographs were presented to 9 fellowship-trained practicing glaucoma specialists on one of two high-definition, nonstereoscopic computer view screens in randomized orders. The view screens were calibrated to have same background brightness, and the ambient lighting was kept constant during the grading process. There was no time limit to completing the grading task, although the entire task was performed in one sitting without breaks. The 9 glaucoma specialists had practice range between 3 and 42 years (median 6 years). The glaucoma specialists were asked to provide a c/d estimate to the nearest 0.05. In order to assess intergrader reliability, an intraclass correlation coefficient (ICC) was calculated for each of the 3 brightness groups. ICC values range from 0 to 1, with 0 indicating no agreement between graders and 1 representing perfect agreement between graders. Commonly cited ranges for ICCs are < 0.40 indicating poor agreement; 0.40 to 0.59 indicating fair agreement; 0.60 to 0.74 indicating good agreement; and > 0.75 indicating excellent agreement between graders [7] . Mean c/d gradings for each of the 3 light settings were compared with each of the others using a paired t test. A paired t-test was performed in lieu of both Analysis of Variance (ANOVA) and independent samples t-test because each of the three comparisons is independently relevant, and the same 50 eyes were used for each of the three light brightness groups. Additionally, the relationship between graders' years in practice and variability of their c/d grades was assessed using a Pearson correlation coefficient. Coefficient of variation, defined as the standard deviation divided by the mean, was used to quantify the variability of the c/d gradings. Coefficient of variation was used in lieu of standard deviation (SD) or variance because it displays variability in the context of the mean. Calculation of the ICC values was performed using SPSS (IBM SPSS Statistics for Windows, Version 27.0); all other data analyses ICC values calculated for the dark, medium, and bright groups were 0.74, 0.71 and 0.65, respectively. Each of these indicates "good" agreement between graders and thus satisfactory intergrader reliability. Across all of the photographs evaluated by the 9 glaucoma specialists, the mean c/d was 0.50. The mean c/d (± SD) for each of the three groups was 0.47 (± 0.11) in the dark group (n = 50), 0.48 (± 0.11) in the medium group (n = 50), and 0.53 (± 0.12) in the bright group (n = 50). When the 3 photograph groups were compared against each other, the bright photograph c/d gradings were statistically significantly larger compared to the medium photographs (0.53 vs 0.48, P < 0.001) as well as the dark photographs (0.47, P < 0.001) ( Table 1) . Although the mean c/d grading at the medium intensity (0.48) was larger than that of the dark intensity photographs (0.47), this difference is minor and fails to reach any statistical significance ( Table 1) . The mean c/d of the nine individual graders ranged from 0.39 to 0.56. No relationship was found between years in practice and the variability of the c/d grading (r = 0.12, P = 0.76) (Fig. 2 ). Our data suggest that the light intensity used in digital nonstereoscopic color disc photography can affect the c/d estimation by glaucoma specialists. Among the same patients at the same time points, graders were more likely to assign a higher c/d if the photograph was taken at a bright intensity setting. This may have significant implications in remote telehealth glaucoma screening given the high specificity of disc photographs compared to clinical examination as a glaucoma screening tool [2, 8, 9] . For established patients, inconsistency in the light intensity setting may result in over-calling or the under-calling of a patient's glaucoma progression over time. Additionally, discrepancies could arise if different providers caring for the same patient are using different light settings. These results also suggest that the outcomes of glaucoma screenings may be significantly different based on the light intensity setting of the fundus camera being used. For example, in a retrospective cross-sectional study of Haitian Afro-Caribbean patients screened for glaucoma at community health fairs in Miami, FL, patients were classified as glaucoma suspects if their c/d exceeded 0.7 [8] . Within our sample, 18% of subjects would be classified as glaucoma suspects using the dark intensity setting, and 26% would be considered glaucoma suspects using the bright intensity setting. Although the two study populations differ, this illustrates that light intensity levels could potentially impact glaucoma screening outcomes. Since c/d remains a useful measure for glaucoma detection in community screening programs and retrospective studies, a standard protocol for light intensity setting may improve the accuracy of both. This study has several limitations. First, we did not standardize the way by which the glaucoma specialists were asked the evaluate c/d nor did we assess intraobserver reliability, which may have contributed to the variability. However, this unstructured approach may simulate the real-world approach more closely than a structured c/d grading, as practitioners of remote telehealth ophthalmology likely do not utilize any fixed, standardized approach in c/d estimates either. Second, we did not measure the pupil diameter or the precise light intensity at each photograph, which limits our ability to comment on the technical details of each photograph. We also did not label and analyze separately Table 1 Cup to disc ratio means and comparisons among the 3 brightness settings The mean c/d gradings for each of the 3 brightness groups, dark, medium, and bright, were compared to each of the others using paired t tests*; c/d (cup to disc ratio), SD (standard deviation) glaucomatous vs nonglaucomatous optic discs, and thus we do not know if the effect of light brightness on c/d grading affects one type of optic discs more than the other. Lastly, our graders consisted only of glaucoma specialists, which may limit the generalizability of our data to the real world practitioners which may comprise of ophthalmologists with various training background. Nevertheless, our findings suggest that light intensity during color disc photography may be an important factor affecting c/d grading. Light intensity used during digital disc photography can significantly affect c/d estimates, which may have real world implications as telehealth ophthalmology care and remote digital disc photography become more popular. Going forward, practitioners should incorporate photograph brightness into their assessment of disc photographs, especially in assessing c/d in the setting of glaucoma screening. Abbreviations c/d: Cup to disc ratio; ICC: Intraclass correlation coefficient; SD: Standard deviation; ANOVA: Analysis of Variance. Variability of expert observers in evaluating the optic disc Gaps in Glaucoma care: a systematic review of monoscopic disc photos to screen for glaucoma Smartphone fundus photography: a narrative review Tele-ophthalmology: need of the hour Glaucomatous optic neuropathy evaluation (GONE) project: the effect of monoscopic versus stereoscopic viewing conditions on optic nerve evaluation The definition and classification of glaucoma in prevalence surveys Guidelines, criteria, and rules of thumb for evaluating normed and standardized assessment instruments in psychology Evaluation of Nonmydriatic hand-held optic disc photography grading in the Philadelphia Glaucoma detection and treatment project Glaucoma screening in the Haitian afro-Caribbean population of South Florida Publisher's Note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations The authors would like to acknowledge the Litowitz family for their generous support of the Balkan International Pediatric Glaucoma Center's research efforts. 1 Authors' contributions ER, AG, and TC were involved in study design and data collection. MM analyzed and interpreted the study data, and wrote the manuscript. TC was a major contributor in the editing of the manuscript. All authors reviewed and approved the final manuscript. The project was supported by NIH Center Core Grant P30EY014801, Research to Prevent Blindness Unrestricted Grant, 2021 Glaucoma Research Foundation Shaffer Grant and Grant Number UL1TR002736, Miami Clinical and Translational Science Institute, from the National Center for Advancing Translational Sciences and the National Institute on Minority Health and Health Disparities. Its contents are solely the responsibility of the authors and do not necessarily represent the official views of the NIH. The data generated and analyzed during this study are available from the corresponding author on reasonable request. The study protocol was approved by the University of Miami Miller of School of Medicine Institutional Review Board/Ethics Committee, adhered to the tenets of the Declaration of Helsinki and complied with the Health Information Portability and Accountability Act. Informed consent was obtained for all of the patients in this study to have the images used for research, education, and quality assurance purposes. This report does not contain any of the images or personal information that could lead to the identification of the patients. Not applicable. The authors declare that they have no competing interests.