key: cord-1035542-72mz44fg authors: Singh, Arpana; Gupta, Pratima; Mathuria, Yogendra P; Kalita, Deepjyoti; Prasad, Amber; Panda, Prasan K; Bahurupi, Yogesh; Sahoo, Biswajeet; Omar, Balram Ji title: Comparative Evaluation of Nasopharyngeal and Oropharyngeal Swab Based Rapid SARS-CoV-2 Antigen Detection and Real-Time RT-PCR for Diagnosis of COVID-19 in Tertiary Care Hospital date: 2021-07-31 journal: Cureus DOI: 10.7759/cureus.16785 sha: a331615f8dde19db8e52939f94ea78e632a3be50 doc_id: 1035542 cord_uid: 72mz44fg Purpose: To assess and compare the diagnostic accuracy of the GenBody COVID-19 Antigen kit (GenBody Inc., Cheonan, South Korea) available in the market with the gold standard reverse transcription-polymerase chain reaction (RT-PCR) assay to detect severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2). Methods: Nasopharyngeal and oropharyngeal swabs were collected from suspected coronavirus disease 2019 (COVID-19) patients and tested by RT-PCR and GenBody Rapid antigen kit. Performance characteristic of the antigen kit was calculated. Results: We tested nasopharyngeal swabs and oropharyngeal swabs (n=240). Amongst the 102 positive RT-PCR samples, the rapid antigen test detected 36 as positive, showing an overall sensitivity of 35.3%. All the samples detected positive with the antigen rapid test were also detected positive by RT-PCR. Conclusion: The performance of the rapid antigen kit was good with respect to high viral load samples, whereas those with lower levels were missed. Unfortunately, the overall low sensitivity of the antigen kit does not allow using it alone as the frontline testing kit for COVID-19 diagnosis. The coronavirus disease 2019 (COVID-19) pandemic has created havoc worldwide since it was first recorded in Wuhan, the capital city of Hubei province, China, in December 2019 [1] . The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is a single-stranded RNA virus that belongs to the genus β of Family Coronaviridae. Being highly transmissible, this novel coronavirus disease has spread fast worldwide [2] . The World Health Organization (WHO) declared COVID-19 as a pandemic on 11 March 2020 [3] . The gold standard tests to diagnose SARS-CoV-2 infections are viral culture and reverse transcription-polymerase chain reaction (RT-PCR) assays [4] . Although it takes a few hours for RT-PCR to detect the nucleic acid and isolation of the virus from samples takes some days, but these tests need a specialized instrument and trained people in that particular field. There is an upsurge in the number of cases, especially in countries like the United States, Brazil, and India. Therefore, rapid tests for SARS-CoV-2 might play an important role in mass screening to facilitate prevention and control of disease and screening before any surgical procedure [1] . The rapid antigen detection (RAD) tests are immunochromatographic tests, commercially available as lateral flow detect viral antigen by the immobilized SARS-CoV-2 antibody coated on the device. These lateral flow assays which use monoclonal antibodies specific to SARS-CoV-2 antigens extracted from the nasopharyngeal and oropharyngeal swabs can be utilized as the screening tests if their diagnostic accuracy were similar to that of the real-time RT-PCR assays. The RAD test takes less time and gives the results within 30 min without the need for any specialized instrument. Hence, RAD tests can drastically improve turnaround time and reduce the workload in already strained diagnostic hospitals and laboratories. As per WHO, the role of RAD tests to detect antigen for SARS-CoV-2 needs to be further evaluated and is not recommended for clinical diagnosis [5] . The purpose of this study is to assess the role of the GenBody COVID-19 Antigen test (GenBody Inc., Cheonan, South Korea) for laboratory confirmation of the cases. The objective of the study was to estimate the performance characteristics of the RAD test to detect SARS-CoV-2. Performance characteristics of the SARS-CoV-2 antigen detection kit were analyzed in comparison to the RT-PCR assay. Respiratory specimens, nasopharyngeal swabs, and oropharyngeal swabs were collected. Samples were collected and mixed in viral transport media (VTM) and immediately transported to the virology laboratory maintaining the cold chain where these samples were tested with RT-PCR and rapid antigen test kits simultaneously. All the specimens were processed in biosafety cabinet level 2 (BSL 2 Advanced) following all infection control practices. Automated system Kingfisher Flex 96 system (Thermofisher Scientific Inc., Waltham, Massachusetts, US.) was used to extract SARS-CoV-2 RNA from 200 μL of a sample. Extraction was performed according to the manufacturer's instructions using a magnetic bead-based MagRNA extraction kit (Thermofisher Scientific Inc., Waltham, Massachusetts, US). Viral RNA extract was eluted in 80 μL of the elution buffer and an RT-PCR assay was performed. Antigen test is a rapid chromatographic immunoassay for the detection of SARS-CoV-2 nucleocapsid (NP) antigen in human respiratory specimens. An aliquot of 400 μL of the sample was added to the extraction buffer given in the GenBody COVID-19 Antigen kit. The nasopharyngeal (and oropharyngeal) swab sample(s) was inserted into the extraction solution, then, the swab was mixed 8~10 times. Swabs were removed while pressing against the solution tube in order to extract most of the specimen. Four drops (~100 µL) were dropped into the sample well (S). The test results were interpreted after 15~20 min as per the kit's instructions. Diagnostic accuracy of both tests was performed. Descriptive statistics were used to describe the demographic details of patients. Continuous data were presented in mean, standard deviation (SD), median, and range. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated using an online statistical tool IBM SPSS statistics for Windows software v22 (IBM Corp., Armonk, NY). Out of the total samples tested from suspected COVID-19 cases (n=240) by real-time RT-PCR assay and rapid antigen kit, 42.5% (n = 102) were positive for SARS-CoV-2 RNA by RT-PCR, and 35.3% were positive for SARS-CoV-2 nucleocapsid antigen. The median age for COVID-19 cases was 30 years (range 5-60 years). Out of the total infected cases, 60.70% (n = 62) were males and 39.21%(n=40) were females. Symptomatic The average cycle threshold (Ct) values in COVID-19 positive cases were 25.30 (minimum 12, maximum 33.78). The sensitivity of RAD was found to be very low compared to very high specificity, as shown in Table 1 . In a sub-group analysis, we divided the respiratory samples of the positive cases into two groups based on the Ct values obtained in the RT-PCR assay. This part of the study was done based on the observations by Mak et al. [5] . Based on the Ct cut-off value, samples with Ct <18.57 were designated as 'high viral load' while samples with Ct>18.57 were categorized as 'normal viral load'. The corresponding Ct values, mean Ct value, Ct value range, and sensitivity were calculated as shown in Table 2 . A significant difference in the performance of the rapid detection test (RDT) was found in patients with 'high viral load' and 'normal viral load' (p-value = .000022). In another sub-group analysis, the test performance of RDT was calculated in different age groups as shown in Table 3 . In this study, the performance characteristics of the RAD test by the rapid antigen kit were determined to detect the SARS-CoV-2 virus in respiratory samples. Results of the RAD test were compared with the results of RT-PCR as the gold standard. We observed that the sensitivity and NPV of RAD were found to be very low compared to the RT-PCR test to identify SARS-CoV-2 infections in respiratory samples. Most of the samples having Ct values relatively on the higher side representing normal viral load were not detected by the rapid antigen kit. In this era of the ongoing pandemic of COVID-19, prompt diagnostic testing for SARS-CoV-2 is crucial for the proper management of infected patients and to limit the spread of the virus. Molecular tests like RT-PCR assays are the standard tests for laboratory confirmation [6] . In view of an increasing number of cases every day, rapid antigen immunoassays will help to speed up the screening for the disease. Different rapid tests have been developed by companies based on SARS-CoV-2 proteins in respiratory samples. However, there are many factors that affect the analytical performances of these rapid antigenic tests like the viral load, the specimen quality, method of processing the sample, stage or timing of infection, and also the setting of the patient [1] . As reported by the manufacturer, the sensitivity and specificity of the rapid antigen test (total n = 30; positive n = 27; negative n = 3) were 90% (95% CI, 73.47-97.89%), and 98% (95% CI, 92.96-99.76%), respectively. Our results showed higher specificity (100%) but low sensitivity (35%). The batch of clinical specimens tested by the manufacturer might generally have higher viral loads (low Ct-value) than our samples. Our test performance differs from the manufacturer's which may be due to various factors, including the lots of kit reagents used, the quality of the sample, amount of extracted antigen, handling of samples, and their processing techniques. A negative test result does not rule out the presence of antigen. It may give negative results due to their lower levels of extracted antigen than the limit of detection of the kit. The lack of sensitivity of rapid diagnostic tests for virus detection is well known and similar results were already observed during the Influenza A (H1N1) pandemic [7] . A recent study by Scohy et al. and Ciotti et al. also observed similar overall sensitivity by performing another rapid antigen test to diagnose COVID-19 to be 30.2% and 30.77% respectively [8, 9] . Other studies evaluating the performance of rapid detection tests are shown in Table 4 . Low sensitivity of the rapid antigen kit may lead to false-negative results, which can be of great consequence in this pandemic. Therefore, such tests should not be recommended alone in clinical settings. Before adopting antigen-based tests we should consider the balance between cost, turnaround time, ease of performance, and more importantly its sensitivity [19] . The present study confirmed high PPV and NPV during the high viral load phase of illnesses. Hence, this may be recommended during the initial period of illness only. Given the fact that rapid antigen kits are designed such that they do not amplify the target genes like PCR, so target proteins if present in a lower amount may be missed. These rapid tests can be used for mass screening, but real-time PCR, being the gold standard, should be used to confirm the negative cases of COVID-19. Human subjects: Consent was obtained or waived by all participants in this study. All India Institute of Medical Sciences, Rishikesh Institutional Ethics Committee issued approval AIIMS/IEC/21/09. Institutional Ethics committee, All India Institute of Medical Sciences, Rishikesh (Ethics Approval No :AIIMS/IEC/21/09) had approved this research proposal. Animal subjects: All authors have confirmed that this study did not involve animal subjects or tissue. Conflicts of interest: In compliance with the ICMJE uniform disclosure form, all authors declare the following: Payment/services info: All authors have declared that no financial support was received from any organization for the submitted work. Financial relationships: All authors have declared that they have no financial relationships at present or within the previous three years with any organizations that might have an interest in the submitted work. Other relationships: All authors have declared that there are no other relationships or activities that could appear to have influenced the submitted work. Rapid SARS-CoV-2 antigen detection assay in comparison with real-time RT-PCR assay for laboratory diagnosis of COVID-19 in Thailand Characteristics of SARS-CoV-2 and COVID-19 WHO, Coronavirus disease (COVID-2019) situation report -51 COVID-19) in suspected human cases: interim guidance Evaluation of rapid antigen test for detection of SARS-CoV-2 virus ICMR-advisory on use of rapid antigen detection test for COVID-19 Evaluation of rapid influenza diagnostic tests for detection of novel influenza A (H1N1) Virus -United States Low performance of rapid antigen detection test as frontline testing for COVID-19 diagnosis Performance of a rapid antigen test in the diagnosis of SARS-CoV-2 infection Evaluation of a SARS-CoV-2 rapid antigen test: potential to help reduce community spread Clinical evaluation of self-collected saliva by quantitative reverse transcription-PCR (RT-qPCR), direct RT-qPCR, reverse transcription-loop-mediated isothermal amplification, and a rapid antigen test to diagnose COVID-19 Evaluation of clinical utility of novel coronavirus antigen detection reagent, Espline® SARS-CoV-2 Diagnosing SARS-CoV-2 with antigen testing, transcriptionmediated amplification and real-time PCR Evaluation of performance of the BD Veritor SARS-CoV-2 chromatographic immunoassay test in patients with symptoms of COVID-19 Potential use of antigen-based rapid test for SARS-CoV-2 in respiratory specimens in low-resource settings in Egypt for symptomatic patients and high-risk contacts Efficacy comparison of three rapid antigen tests for SARS-CoV-2 and how viral load impact their performance Performance characteristics of a rapid SARS-CoV-2 antigen detection assay at a public plaza testing site in San Francisco Diagnostic performance of a SARS-CoV-2 rapid antigen test in a large, Norwegian cohort Laboratory diagnosis of swine flu: a review The authors would like to acknowledge Mr. Nitin Gupta for arranging and providing the kits and consumables for the project.