key: cord-1050685-gekcs2yn authors: Berkenbrock, José Alvim; Grecco-Machado, Rafaela; Achenbach, Sven title: Microfluidic devices for the detection of viruses: aspects of emergency fabrication during the COVID-19 pandemic and other outbreaks date: 2020-11-04 journal: Proc Math Phys Eng Sci DOI: 10.1098/rspa.2020.0398 sha: 7f54cee1f645e7ca148c0122fbb178e0aa8add53 doc_id: 1050685 cord_uid: gekcs2yn Extensive testing of populations against COVID-19 has been suggested as a game-changer quest to control the spread of this contagious disease and to avoid further disruption in our social, healthcare and economical systems. Nonetheless, testing millions of people for a new virus brings about quite a few challenges. The development of effective tests for the new coronavirus has become a worldwide task that relies on recent discoveries and lessons learned from past outbreaks. In this work, we review the most recent publications on microfluidics devices for the detection of viruses. The topics of discussion include different detection approaches, methods of signalling and fabrication techniques. Besides the miniaturization of traditional benchtop detection assays, approaches such as electrochemical analyses, field-effect transistors and resistive pulse sensors are considered. For emergency fabrication of quick test kits, the local capabilities must be evaluated, and the joint work of universities, industries, and governments seems to be an unequivocal necessity. The preparation of this manuscript started amid one of the most severe virus outbreaks of our recent Many questions remain about the behaviour of SARS-CoV-2, including how its mortality rate compares to other coronaviruses. It is especially difficult to predict the mortality rate of a current outbreak due to the uncertainties inherent to an evolving process. One limitation of the estimations on the mortality rate is assessing the actual number of infected people [8, 25] . Current estimations of the mortality rate for COVID-19 vary from 0.9% up to 8% or more [12, 25] . For patients in critical care, it has reached levels as high as 52% in Washington (USA) and 62% in Wuhan (China) [26] . Most countries were not able to extensively test the population in the rise of COVID-19, diminishing the accuracy of mortality rate numbers in the wider population. Some places have therefore later employed home-tests to assess the number of people who have already developed antibodies against SARS-CoV-2 [27] [28] [29] . This afterward-testing can contribute to an improved approximation of the actual mortality rate. In comparison with other coronaviruses, between 2003 and 2004, SARS caused close to 800 deaths worldwide with a mortality rate lower than 10% [1, 11, 24, 30] . In 2012, MERS emerged causing a similar number of fatalities, however, with a mortality rate higher than 34% [1, 11, 24] . Along with outbreaks caused by new strains of coronaviruses, emergent novel influenza strains have also imposed threats globally [31] . The number of deaths related to influenza per year is estimated to be between 291 000 and 646 000 with a mortality rate ranging from 4.0 to 8.8 per 100 000 individuals (i.e. 0.004% to 0.009%) [32] . The highest influenza mortality rate is among older patients (51.3 to 99.4 per 100 000 individuals). However, about 9243-105 000 deaths were estimated among children younger than 5 years, too [32] . In the ongoing SARS-CoV-2 pandemic, COVID-19 killed more than 917 000 people worldwide in 9 months and infected about 28 million people. There are other viral infections considered epidemics that present local and global threats to human health. Dengue is a wide-spread disease that has affected more than 100 countries and has caused 10 000 deaths worldwide per year [33] . Other viral outbreaks have been restricted to some areas of the globe, such as Chikungunya, Zika and Ebola viruses. They caused, however, numerous fatalities and resurface over the years. The fatality rate of Chikungunya (1/1000) is higher than that of dengue (0.5/1000) and lead to about 200 deaths just in Brazil in 2016 [34, 35] . Between 2015 and 2016, an outbreak of Zika was reported in the Pacific Islands and American countries [36, 37] . The morbidity caused by Zika can lead to disabilities lasting a lifetime [37] . For Ebola, the fatality rates reported by the WHO varied from 25% to 90% in the past. A total of 28 616 cases have been reported in Guinea, Liberia and Sierra Leone, with 11 310 deaths [38] . Ebola continues to resurface and in 2018, about 50 deaths were attributed to the virus in the Democratic Republic of the Congo [39] . These numbers indicate the importance of creating detectors that can be largely produced and used among populations with different societal, economic and cultural backgrounds. In this section, some common fabrication techniques for microfluidic devices are reviewed. The discussion focuses on the most frequently used techniques for the fabrication of microfluidic detectors, which include printing and cutting, moulding and photolithography. Paper-based microfluidic detectors are robust, cost-effective and user-friendly devices [40, 41] . They can be used for the diagnosis of a variety of viruses [41] [42] [43] [44] [45] [46] [47] . There are many advantages in using paper-based devices: e.g. this material is readily available worldwide, and its properties allow for easy transport of liquids using passive flow [41] . Also, various types of paper are compatible with printing and other patterning technologies, increasing their applicability [41] [42] [43] [44] . An example of a paper-based device for viral detection was presented by Magro et al. [43] for the diagnosis of the Ebola virus. Using wax on folding paper and double-stick tape, the group created a device that allowed a multiplexed analysis (figure 1). The fabrication steps were printing and cutting, adding RT-RPA 1 reagents, and freeze-drying the device. The devices could be stored and delivered to locations in need, although it still required RNA extraction of filtered blood as a first analysis step [43] . Paper-based devices were also used for the diagnosis of mosquito-borne RNA viruses such as Zika, Dengue and Chikungunya [42, [44] [45] [46] [47] . Batule and co-workers [44] presented a multi-step process for detecting these viruses consisting of two devices. The first one allowed the extraction of viral RNA based on single-strand DNA probes from the sample, while the second device was used to perform an RT-LAMP (loop-mediated isothermal amplification 2 ) assay for sample amplification. Although the complete system requires a fluorescence imaging system for reading, the results were comparable to RT-qPCR. Even though much has still to be researched on paper-based immunosensors, these biosensors are cheap, easy to handle, biocompatible and biodegradable, which can make them a promising option to be widely used in regions with limited resources. Different micro-replication techniques can be used for the fabrication of a large number of devices usually made of polymers [49] . Variations of compression moulding (i.e. embossing) and injection moulding are widely employed for the fabrication of microfluidic devices [5, [50] [51] [52] [53] [54] [55] . Fernández-Carballo et al. [5] fabricated a mould in steel for high-volume manufacture of an RT-PCR chip. Using this mould, the authors suggested that 200 chips could be produced per hour [5] . This ability to produce several devices with a single mould would be advantageous for localities with difficult access to sophisticated microfabrication laboratories. Another example of fluidic chips fabricated using the moulding process was presented by Wang et al. [51] . The team produced a LAMP-integrated chip on polycarbonate with microchannels (500 µm wide and 200 µm deep) and overall size of 2 × 1 × 1 mm 3 [51] . Chip fabrication using moulding processes for tailoring polymers (figure 2) is simpler than photolithography and the process itself induces lower costs [53] . Some disadvantages of the moulding process are related to the required heat and pressure which may lead to tool deterioration, polymer sample deformation/shrinkage and other fabrication defects [53] . Photolithography is a very well-established process used in micro-and nanofabrication. The fundamental elements in this process include a light source (e.g. ultraviolet radiation), a mask and a substrate coated with a photoresist (i.e. photosensitive material) [15, 49] . In brief, a pattern on the mask is transferred to the photoresist by exposure to the UV radiation. In the resist, a chemical reaction is catalysed with the UV photons (figure 3). After eventual thermal treatment (baking steps), wet chemical development selectively removes either the exposed or the unexposed resist areas (depending on the type of resist). These basic fabrication steps of lithography deliver a primary polymer microstructure. It can be used as fluidic channels and hence, after appropriate sealing, be used as the final microfluidic device. Alternatively, the resist pattern can be applied as a processing mask in subsequent processing steps, such as is etching or electroplating. Additional Figure 3 . Process steps for the fabrication of a microfluidic device using photolithography and subsequent processes. (i) Using exposure to UV radiation, a mask pattern is transferred to a photoresist which was previously coated on a rigid substrate. (ii) The sample is wet chemically developed, i.e. either the exposed or the unexposed resist areas are selectively removed. Depending on the resist, intermediate thermal treatment steps (baking) may be required. This delivers the primary polymer microstructure, which may serve as the final fluidic device (see process alternative 4a), or it may serve as a processing mask (see all other subsequent processing steps below. (3) After these core lithographic steps, different subsequent processing options are available: the patterned substrate can be sealed (4a), or further processed (4b, 4c). In process variation (4b), the substrate is locally etched, using the resist pattern as a processing mask, and the device can be sealed (5b ). If needed, the resist can be removed (stripped) before sealing (5b , 6b '). In process variation (4c), the resist is used as a processing mask to locally grow metal microstructures by electroplating. This process variation is commonly applied to create a mould which can be used in a moulding process described in the previous paragraph. (Online version in colour.) fabrication steps required in the processing of a detector system may include the generation of electrodes and eventually functionalization of electrodes for the detection of biomolecules [53, [56] [57] [58] . An example of these extra processing steps was presented by Iswardy et al. [56] . Silica beads were functionalized with antibodies (i.e. 4G2) to bind to the Dengue virus (DENV) [56] . The operation of the device was based on dielectrophoretic forces to capture 4G2-coated silica beads flowing in a microchannel. The beads were mixed with the samples, then captured with V-shaped electrodes and imaged with an inverted fluorescent microscope. In this case, the substrate used underneath the microchannel was glass, a common material in microfluidics. Photolithography is a versatile technique that can be performed with a variety of materials [56, [58] [59] [60] [61] [62] . It can be part of a larger fabrication process sequence that may encompass etching, lift-off, electrochemical deposition and doping, for instance [53] . Sophisticated technologies and equipment are required for photolithographic processing. Among common fabrication processes for microfluidics, photolithography typically has the strictest cleanliness requirements, since particle contamination may interfere in pattern transfer, and surface contamination may reduce photoresist adhesion to the substrate [53] . Mass production of microdevices can be simplified, and requirements on the fabrication environment can be relaxed, by omitting the continued use of lithographic approaches when moulds are created. In this case, this lithographic process would only be applied once, and with subsequent electroplating (figure 3, variation 4c). The resulting moulds then still feature lithographic accuracy, but allow for simple and fast replication of the predefined pattern, see the description of the moulding processes above [63] [64] [65] [66] . However, modifications to the mould design require a new round of photolithography fabrication, which includes creating another photomask and all the other steps described earlier. Microfabrication technologies have evolved and have been refined and differentiated, to respond to added requirements imposed by microfluidic sensing/detection tasks. Besides using the most common fabrication processes presented above, microfluidic devices have also been created using, e.g. three-dimensional printers [44, 67, 68] , focused ion beam (FIB) patterning [69] [70] [71] or controlled breakdown (CBD) of membranes [70, 72, 73] . Some detector designs require highly sophisticated fabrication technologies, but many effective new microdevices have been envisaged using simple and largely available technologies like three-dimensional printing or regular printing for paper-based devices. Viruses are generally formed by their genetic codes (i.e. DNA or RNA) and comprise a proteinmade shell and lipid ligands. Detection approaches may be endeavoured for any of these elements. Traditional benchtop assays, such as enzyme-linked immunosorbent assay (ELISA) and western blot are largely used to detect proteins, while polymerase chain reaction (PCR) and its variants are used for the detection and amplification of genetic material. These methods require several types of biotechnological supplies as buffers, genetic-probes, antibodies or fluorescent labels, as well as laboratory plasticware, benchtop equipment and highly trained personnel [74, 75] . Despite, or because, of these downsides of a large number of materials and training required, these traditional techniques excel in accuracy, sensitivity and reliability. A variety of approaches based on benchtop assays can be adapted to microfluidic devices to reduce the quantity of required reagents and to speed up reactions. The translation of traditional techniques into miniaturized versions seemed to be an almost natural developmental step since they apply well-established protocols. In the mid-1990s, the feasibility of a PCR on-a-chip was first demonstrated [20, 76] . These early studies showed a high-speed separation of the DNA bands due to small dimensions of the channels used in the microfluidic devices. Moreover, the temperature could be rapidly changed (on the order of 100 ms), accelerating the two dozens of thermal cycles needed for the reaction [20, 76] . Since the late 1990s, different immunoassays were miniaturized to be performed on microchips. Within a couple of decades, microfluidic devices evolved to elaborated structures capable of detecting complex biological samples. From the initial implementations of PCR on-a-chip in the mid-1990s, researchers rapidly realized the potential of this new technology for diagnosis of health-related conditions, including viral infections. The increased interest to use microfluidic devices for the detection of viruses is reflected by the exponential trend in the number of papers published per year with terms as 'microfluidic', 'detection' and 'viruses' (figure 4). In most of the studied cases, new viruses have been detected with microfluidic platforms soon after the viruses first appeared (figure 4b). This prompt adaptability of miniaturized fluidic detection systems to previous outbreaks may raise hope for the accelerated development of new detectors for COVID-19 and future threads. Detection approaches using microfluidic systems can be adapted for diagnostics of infectious diseases based on viral genetic material. The detectors based on the amplification of the genetic code require the design of specific DNA probes, called primers, that recognize a target sequence at the viral genetic material. In table 1, primers used for the detection of different viruses are presented. A successful example of the detection of the viral genetic material was presented by Fernández-Carballo et al. [5] . The team developed a PoCT qRT-PCR system for the detection of RNA-based viral pathogens [5] . were tested with the primers described in table 1 and two master mix solutions. The group was able to achieve a processing time of 30 min, much faster than typical benchtop qRT-PCR platforms. The limit of detection of the system was about 10 RNA copies per microlitre, which is comparable to benchtop assays [5] . Similar approaches to on-chip amplification of genetic fragments were tested for the detection of avian influenza DNA (H7N9) [107] , influenza A (H1N1) [85] , Zika (ZIKV) [101] , dengue (DENV) [96] , MERS (MERS-CoV) [81] , SARS (SARS-CoV) [77] and COVID-19 (SARS-CoV-2) [79] (table 1) . These different studies show the great potential for microfluidics to replace or supplement benchtop assays for the diagnosis of infectious diseases. Primers with high specificity to detect viral strains have been successfully used together with microfluidic devices to facilitate viral recognition [93, 96] . For example, Yin et al. [96] developed a microfluidic platform for the detection of four different strains of the Dengue virus (DENV1 to 4). The high specificity of each primer allowed the identification of the four DENV and one type of Zika virus (ZIKV) [96] . In the same direction, specific primers were used to differentiate among diverse influenza strains. For the viruses tested, the detection limit varied from 40 to 3000 copies per reaction. Subtypes of influenza A, such as H1N1, H3N2, H5N1, H5N2 and H7N9; the subtypes Victoria and Yamagata of influenza B were detected using this single microfluidic device [93] . Another scenario was presented by Sabalza et al. [101] for the detection of different strains of the ZIKV. The research team used a region of the viral DNA conserved among the different tested strains and targeted a DNA region responsible for the formation of a virus capsid protein. Using a selected number of primers, the device detected multiple Asian-lineage strains of the ZIKV [101] . The selection of a primer for a microfluidic detector, therefore, depends on the target's structural characteristics and how wide-ranging the microdevice is designed to be. A straightforward and cost-effective molecular technique called loop-mediated isothermal amplification (LAMP) has been increasingly used in benchtop assays and miniaturized devices for molecular diagnostics. In contrast with the different temperatures needed for each phase of a PCR cycle, LAMP is based on a single temperature-between 60°C and 65°C-for target amplification [108] . This method is compatible with reverse transcriptase and was used for SARS-CoV testing on a benchtop assay [109] . Microdevices using LAMP have been used to detect Dengue, Zika and Chikungunya [44, 66, 101] , different subtypes of influenza A and B [51, 85] , MERS [81] and SARS [110] . Most recently, an RT-LAMP-based benchtop assay showed the same positive results as the WHO-approved RT-qPCR-based standard for COVID-19 diagnosis [111] . The authors suggested this new protocol could be implemented on microdevices for at-home testing. Mass at-home testing could be an effective way to prevent potential patients to leave their homes, diminishing the risk of spreading viruses such as SARS-CoV-2 [7] . The simplicity of the LAMP protocol has been considered a great advantage for its use in microfluidic devices for point-of-care testing (PoCT) [7, 112] . In a final step, any of the above-mentioned variations of detecting viruses using primer forward: MERcv-sF_ GAGCTTAGGCTCTTTAGTAAG, reverse: MERcv-sR_ TTTTTTTTTTTTGCAAATCATCTAATTAGCCTAA more sequences of primers and probes are described in the original paper [81] . antibody a specific to influenza virus H1N1 was reported but no further detail was presented. amplified biological assays require an interface to the end-user, i.e. a visualization method to indicate a detection event. One typical way is to use gel electrophoresis, which will deliver stained patterns such as the ones known from benchtop devices. Further details are given below, in the chapter on User Interfaces. Unlike the above-mentioned approaches to detect viruses based on their genetic material in PCR or LAMP protocols using primers, the detection of viruses based on their viral proteins is usually performed with the use of antibodies. Antibodies are protective proteins produced by the immune system in response to the presence of a foreign substance, called an antigen (as defined by the Encyclopedia Britannica). Antibodies are generally Y-shaped and have very specific structural characteristics that enable binding only with unique targets. This property is the reason antibodies are widely applied in detectors for biomolecules [98, 105, [113] [114] [115] [116] [117] . An example of a microfluidic detector using antibodies against viral proteins was described by Wang et al. [92] . They developed a device capable of recognizing two subtypes of Influenza A (Inf.-A) simultaneously, based on antibodies immobilized on magnetic beads [92] . Antibodies anti-H7 and anti-H9 were used to detect H7N9 and H9N2 Inf.-A subtype viral proteins in concentrations as low as 3.4 and 4.5 ng ml −1 , respectively [92] . Microfluidic devices can also use aptamers 3 to screen for viruses. Detection of Inf.-A, for example, was possible by using a combination of antibodies and aptamers. The subtypes of the inf.-A virus are characterized by a combination of haemagglutinin (HA) and neuraminidase (NA) proteins [86, 92, 119] . HA is a viral surface protein that participates in the viral invasion and propagation process in host cells [92, 119] . Anti-HA antibodies were used to capture the viruses, and the suitability of several aptamers against H1N1 was tested. The aptamers sensitive to Inf.-A were then tested against Inf.-B, and only those uniquely specific to H1N1 were selected to be used in the device [86] . Specific aptamers can be used to capture the virus, which is then exposed to a primary antibody that binds to the virus surface. The primary antibody enables the linkage to a secondary antibody with a fluorescent element, therefore generating an optically detectable signal [89] . When fighting against pathogens such as viruses, the human body produces several antibodies that will circulate the blood system and potentially neutralize the infectious agent. Another way to detect infections, instead of directly looking for the pathogenic agent, e.g. using antibodies introduced by the detector as described above, is to detect the presence of those antibodies already present in the system of patients [120] : in a method called serological testing, detectors for different diseases use the presence of specific antibodies in the patient's serum as biomarkers, [42, 84, 104, 113, 120, 121] . Microfluidic devices using serological testing have been developed to detect ZIKV, MERS-CoV and DENV. This is therefore also a potentially promising approach to detect SARS-CoV-2 [74] . Recently, Wang et al. [104] presented a capacitive sensor that was evaluated using immobilized ZIKV. Serum samples were tested for the detection of anti-Zika antibodies and the detection happened in concentrations as small as 10 molecules in 30 µl [104] . Similarly, Hoy et al. [84] created a microfiber-based detector for MERS-CoV. The His-MERS-NP antigen protein was immobilized at polystyrene microfibres and exposed to a commercial anti-MERS-NP. Although tests with patient samples are still to be done, the detection limit using a buffer solution was quantified to be 200 µg ml −1 [84] . Another detection approach was followed by Cecchetto et al. [98] who developed a Dengue capacitive detector based on non-structural protein 1 (NS1) [98] . The NS1 is a viral glycoprotein secreted by cells [47] . This protein has been considered a biomarker for early-stage Dengue with concentrations of 0.04-2.00 µg ml −1 in serum-infected patients [100] . In their most recent publication, the group presented a device with a ferrocene-tagged, peptide-modified surface that is equipped with anti-NS1. The presence of the NS1 in the samples was detected by changes in the capacitance of the electrode [98] . In a final step, any of the above-mentioned variations of detecting viruses by linking antibodies to the target particles requires an interface to the end-user, i.e. a visualization method to indicate a detection event. One typical way is to use fluorescent markers that get bound to the target particle and will generate an optical response. Other approaches use electrochemical effects to, e.g. detune electrical properties of electrodes or transistors, in the wake of binding molecules to a functionalized surface or volume. Further details are given below, in the section on User Interfaces. Instead of applying the same detection approaches used in benchtop assays, some microfluidic detectors explore the resistive pulse sensing (RPS) principle [70, 94, 113, [122] [123] [124] . RPS detection is based on effects associated with the translocation of molecules through pores, rather than on chemical bonding as in the previously discussed detection principles. The first description of this technique is attributed to Wallace Coulter in 1953. Since then, the method has been substantially improved and is widely used for counting cells [125, 126] . A resistive pulse sensor, often referred to as a Coulter counter, consists of two reservoirs with their respective electrodes and is filled with a conductive solution (electrolyte). The key component is a small pore (or channel) that connects both reservoirs. The electrodes set up an electric field, which results in an ionic current across the pore. This electric current is dependent on the flow of substances through the pore upon translocation of biomolecules of interest (target elements) through the pore, a temporary rapid increase in the electric resistance occurs. This is the signal that can get evaluated for detection, and which coined the term resistive pulse sensor. In recent decades, micro-and nanofabrication technologies have allowed minimizing the diameter of the pore, creating devices with potentially single-molecule sensitivity [70, 124, 127, 128] . RPS-based detectors were used for single-virus identification for the diagnosis of influenza, with a discriminability above 95% between H1N1 and H3N2 when analysing the detection pattern for 20 virions or more [94] . RPS was also previously used to study the HIV-1 and hepatitis B virus [62, 129] . This technique can be modified in a variety of ways, for example with the use of multi-pore membranes to allow for concurrent detections [130] . This technique is highly sensitive, and the design of the device is simple. Fabrication, however, can be challenging, and the purification of samples imposes a major obstacle for the translation of such devices into PoCT [131] . In the previous section, some approaches for the detection of viruses based on biochemical (e.g. DNA/RNA with primers and antigens with antibodies) and biophysical (e.g. RPS) processes were introduced. In this section, the methods used to indicate the detection to the user, such as fluorescence proteins, optical inspection of PCR bands and peaks in the electric current are discussed. It is a common practice to use fluorescent elements to indicate the detection of a target. These elements can be added to the device [63, 89, 93] , attached to the target element [84, 90, 132] or replicated during amplification steps [5, 101, 133] . Examples of fluorescent elements used in microfluidics are cyanine-5 (Cy5), methylene blue (MB) [79] , fluorescein [77] , fluorescein amidites (FAM), hexachlorinated fluorescein (HEX) [110] , SYTO-82 [134] , AF 488 [56] , EvaGreen and SYBR Green [81, 107] . Fluorescence is a very versatile method that can be used in different materials (e.g. paper [41] , polymers [63] and structure-free [89] ). It can also be adapted to automated analysis via smartphones or desktop scanners [107, 135] . The adaptability of fluorescence methods to smartphones has been helping in the detection of viruses such as H7N9 avian influenza and H1N1 [87, 107] . Shi H7N9 avian influenza. Their system consists of a device for amplification of the target DNA, a bluish light-emitting diode and a narrowband filter. A smartphone can be attached to record the fluorescent signals generated by different dyes (EvaGreen, SYBR Green and FAM fluorescent probe) in real-time [107] . Another system that allows viral detection with the help of a smartphone was presented by Ma et al. [87] . The group developed a method capable of processing a sampleto-answer for the detection of the H1N1 virus in less than 40 min. Their system was based on colorimetric LAMP, a passive microfluidic device and an optical detector. A smartphone was used to control the system and analyse the results. Handheld detector systems have the potential to be used as PoCT afar form laboratories or healthcare facilities [45, 55, 136] . Variations of colorimetric methods which apply modifications of surfaces with chemical components can also be used to indicate the detection of viruses to the user. In these systems, colorimetric signals are caused by coloured immunoreaction labels such as colloidal nanoparticles of gold, carbon and selenium [16] . Teengam et al. [83] used the aggregation of gold and silver nanoparticles to change the colour of their paper wells upon detection of the MERS-CoV and other pathogens. The observed detection limit for MERS-CoV was 1.53 and 1.3 nM for other tested pathogens [83] . Without using fluorescence elements, the group was able to image the results with a regular scanner and to perform the analysis using the software ImageJ (National Institutes of Health, USA). The visible difference upon detection was based on the action of peptide nucleic acids, which were responsible for the aggregation of the nanoparticles and the target DNA binding. Another paper-based detector was presented by Aydin et al. [137] for the detection of Hepatitis B viral DNA. The team used conjugated polyelectrolytes which changed colour upon binding of primer and target DNA. In this device, polyvinylidene fluoride (PVDF) membranes were deposited with poly[N,N,N-triethyl-3-((4-methylthiophen-3-yl)oxy)propan-1aminium bromide] which would be read as orange or pink/grey depending on the conformation between the target and the surface. The detection limit was reported to be 1 nM for clinical samples [137] . This type of detector has the advantage of emitting signals in the visible range, leading to rapid identification of the result without the need for extra processing steps involving UV-light. Electrochemical methods can use variations of the impedance between electrodes to indicate a detection without using extra reagents as fluorescent labels. Different electrochemical assays can be used to monitor the surface or the volume between electrodes while testing a sample. A variety of detectors have been proposed based on the functionalization of the surfaces of electrodes for specific binding of target molecules [46, 57, 61, 98, 99, 102, 103, 138, 139] . As an example, surface functionalization was used for the detection of DENV based on the immobilization of NS1 antigens on the surface of gold electrodes [98] . The bonding between antigen and antibody causes a shift in the impedance (figure 5a) and indicates the presence of the virus in the patient's body. The detection is visualized in Nyquist or Bode diagrams and requires spectroscopy equipment [57, 65, 99, 139] . Another example of functionalized electrodes was used for detecting ZIKV through the immobilization of DNA-hairpin probes on gold discs to capture Zika RNA in the samples [103] . The immobilization process usually requires the use of thiol self-assembled monolayers (SAMs) or similar functional groups [57, 142] . The functionalized electrodes that allow for the binding of the viral RNA to detect ZIKV were coupled with a four-way junction sensor. A fourway junction sensor is a multi-component sensing element designed to specifically hybridize with the target genetic material providing a measurable signal [143, 144] . Field-Effect Transistors (FET) and RPS are label-free detectors that use the electric current to indicate detection. FET-based detectors-also referred to as immunoFET devices-are used for immune assays and early diagnosis. In these devices, the interactions between the binding elements immobilized on the surface and the target particles in a solution induce electrostatic perturbations that alter the voltage threshold of the transistor [114] . The curves of the characteristic transfer function show a shift upon antigen-antibody binding in comparison to non-specific antigens [105, 106, 116] (figure 5b). FET-based sensors were described to detect the Ebola virus through the immobilization of Anti-EBOV antibodies on the surface of the device and by monitoring the electric current [105] . Recently, Seo et al. [145] presented a graphene-based FET for the detection of SARS-CoV-2 using immobilized spike antibodies. The group was able to achieve a detection limit of 2.42 × 10 2 copies per ml of clinical samples. RPS is another class of label-free detectors in which the variation of the electric current through a pore can be used to indicate the detection of viruses [74] . Tsutsui et al. [130] used an RPS with a nanopore with a diameter of 300 nm to detect and discriminate between different influenza viruses [130] . For the detection of nanoparticles with 200 nm diameter, the team reported spikes in the electric current on the order of 1 nA. An example of an electric current time signal for detection events using RPS is represented in figure 5c . Label-free detectors can reduce the number of required reagents. Some variations even require no biochemical elements at all. In emergency fabrication situations, the ability to perform specific detections without the need for extra biotechnological products for labelling may be considered advantageous [74] . Within about half a year, COVID-19 has spread globally, causing hundreds of thousands of fatalities. The current scenario has put immense pressure on healthcare and economic systems worldwide. The sanitary situation is unparalleled in recent years. It has called for far-reaching restrictions in people's lives, such as social distancing requirements, work, school and travel restrictions, and local shutdowns. It has also led to a spike in demand for hygiene items such as 70% alcohol, personal protective equipment (PPE) such as masks and face shields, mechanical respirators and screen test kits. from small and large companies, universities and common citizens to find ways to help. Despite of, or even because of, all these efforts, a critical bottleneck in this pandemic became evident: around the globe, there is a lack of reliable screen test kits for a new virus to prevent the unrestrained spreading of a disease such as COVID-19. Therefore, the ability to rapidly produce test kits for quick diagnosis seems to have become instrumental to avoid further social and economic disruptions while facing new varieties of contagious diseases. In the present work, we have discussed some of the most recent advancements in microfluidic-based detectors for viruses. The devices reviewed are based on a variety of approaches and methods but are all capable of detecting and discriminating viral targets in real test samples from medical patients. Many highly efficient microfluidic devices have taken advantage of well-established benchtop assays (i.e. implemented in macroscopic analysis tools rather than miniaturized, portable devices) and adapted them to miniaturized lab-on-a-chip versions. This is possible because recent concentrated research efforts on the SARS-CoV-2 virus have unveiled its genetic material, the proteins and other molecules that form the virus, and the memory antibodies for the disease [146] [147] [148] . These discoveries allowed for the development of new microfluidic detectors based on biological ligands. One such category of detectors uses primers as biological ligands when applying protocols involving the amplification of genetic material (e.g. DNA, RNA), such as polymerase chain reaction (PCR) and loop-mediated isothermal amplification (LAMP). Another such category uses antibodies as biological ligands to bind target particles for the detection of viruses based on their viral proteins [79, 145, 149] . Besides, other innovative solutions to detecting viruses exploit fabrication capabilities of micro-and nanotechnology to detect viruses with fewer or even no biological ligands but rather based on their geometry or electrical properties. Resistive pulse detectors are an example of this category of devices. The different detection approaches are compatible with different visualization methods to indicate detection events. Some common methods are based on fluorescent markers, on colorimetric approaches, on electrochemically induced shifts in the spectroscopic response, on modified transfer functions of involved transistors, or on modified current signals. The combination of the various detection and visualization/interface methods allows for a range of sensitivities and resolution limits, but also strongly varies the requirements for device complexity and supporting biochemical supplies. A common guideline for the commercial success of micro-and nanotechnology products claims that 'simpler is better'. This attitude likely bears additional value when rapid development of new detector devices and fast fabrication are needed, such as under emergency fabrication requirements as in the situation imposed by a pandemic such as COVID-19. In this context, paperbased devices offer unique characteristics of the ubiquitous availability of material and relatively easy fabrication and disposal processes. This might be the simplest kind of a microfluidic device that can be rapidly adapted, and mass-produced for home testing populations. However, even those paper-based devices still require primers or antibodies for detection, which might constitute a problematic obstacle for developing, emerging or low gross domestic product countries [150] . The same dependency on biotechnological material is required for electrochemistry-based detectors, which may additionally rely on large benchtop equipment such as spectrometers. An electrochemistry-based detection method that does not require much additional equipment or supplies is based on FET (immunoFET devices). The fabrication of sophisticated FET-based detectors, however, can be quite challenging and may not be feasible in many regions of the globe. New protocols to create micro and nanopores for RPS-based devices fall into the same category as the FET devices mentioned above -elimination of the need for biological ligands at the expense of much-increased fabrication challenges. The sensitivity of RPS detectors to the size and shape of the target particle eliminates the need for primers or antibodies, but there is still the need for highly complex fabrication capabilities and very sensitive amperemeters. In summary, a large variety of methods and approaches can be applied for the detection of viruses using microfluidic devices. They much vary in the complexity of the fabrication process, in the need for biochemical supplies and ancillary instruments, and detection properties. Therefore, no single approach stands out as a best-fit solution. Instead, a selection from the presented alternatives, or additional new ones potentially getting developed, should be made based on the complexity of the detection and discrimination of the specific virus of interest and based on local community needs and, cost considerations, and delivery timelines to find an adequate solution for producing screening tests and making them widely available. Data accessibility. This article does not contain any additional data. Clinical features of patients infected with 2019 novel coronavirus in Wuhan 2020 World Health Organization declares global emergency: A review of the 2019 novel coronavirus (COVID-19) Coronavirus disease 2019 (COVID-19) Situation Report -67 Coronavirus disease 2019 (COVID-19) Situation Report -69 Continuous-flow, microfluidic, qRT-PCR system for RNA virus detection Coronavirus tests: researchers chase new diagnostics to fight the pandemic 2020 Humanity tested Covid-19: testing times 2020 How will countrybased mitigation measures influence the course of the COVID-19 epidemic? 2020 Outbreak of COVID-19 -an urgent need for good science to silence our fears? COVID-19) epidemics, the newest and biggest global health threats: what lessons have we learned? 2020 COVID-19 in Italy: momentous decisions and many uncertainties Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCR Miniaturized total chemical analysis systems: A novel concept for chemical sensing Theory, fabrication and applications of microfluidic and nanofluidic biosensors Detection platforms for point-of-care testing based on colorimetric, luminescent and magnetic assays: A review Quantification of virus particles using nanopore-based resistivepulse sensing techniques 2020 Recent advances in lab-on-a-chip technologies for viral diagnosis The polymerase chain reaction Chemical amplification: continuous-flow PCR on a chip Microfluidic single-cell analysis of intracellular compounds Performance of the Trioplex real-time RT-PCR assay for detection of Zika, dengue, and chikungunya viruses Simplified immunoassay for rapid Dengue serotype diagnosis, revealing insensitivity to non-specific binding interference MERS coronavirus outbreak: Implications for emerging viral infections 2020 Real estimates of mortality following COVID-19 infection Intensive care management of coronavirus disease 2019 (COVID-19): challenges and recommendations An evaluation of COVID-19 serological assays informs future diagnostics and exposure assessment Community prevalence of SARS-CoV-2 virus in England during May 2020: REACT study. medRxiv Epidemiology, transmission dynamics and control of SARS: The 2002-2003 epidemic MERS-CoV and H5N1 influenza virus antagonize antigen presentation by altering the epigenetic landscape Estimates of global seasonal influenza-associated respiratory mortality: a modelling study The global burden of dengue: an analysis from the Global Burden of Disease Study Alert: Severe cases and deaths associated with Chikungunya in Brazil Chikungunya fever: a threat to global public health Zika virus in the Americas: Early epidemiological and genetic findings Implications of Zika virus and congenital Zika syndrome for the number of live births in Brazil Heterogeneities in the case fatality ratio in the West African Ebola outbreak 2013-2016 Outbreak of Ebola virus disease in the Democratic Republic of the Congo LAMP-on-a-chip: Revising microfluidic platforms for loop-mediated DNA amplification 2020 Paper-based microfluidics for rapid diagnostics and drug delivery Paper-based antibody detection devices Using Bioluminescent BRET-Switching Sensor Proteins Paper-based RNA detection and multiplexed analysis for Ebola virus diagnostics Paper-based nucleic acid testing system for simple and early diagnosis of mosquito-borne RNA viruses from human serum Simpler, faster, and sensitive zika virus assay using smartphone detection of loop-mediated isothermal amplification on paper microfluidic chips Paper based DNA biosensor for detection of chikungunya virus using gold shells coated magnetic nanocubes Paper-based point-of-care testing for cost-effective diagnosis of acute flavivirus infections Recombinase polymerase amplification for diagnostic applications Handbook on advanced design and manufacturing technologies for biomedical devices Microfluidics in structured multimaterial fibers Rapid detection of multiple respiratory viruses based on microfluidic isothermal amplification and a real-time colorimetric method Rapid and inexpensive method for the simple fabrication of PDMS-based electrochemical sensors for detection in microfluidic devices Micro and nano fabrication A wearable microfluidic device for rapid detection of HIV-1 DNA using recombinase polymerase amplification 2020 A new microchannel capillary flow assay (MCFA) platform with lyophilized chemiluminescence reagents for a smartphone-based POCT detecting malaria A beadbased immunofluorescence-assay on a microfluidic dielectrophoresis platform for rapid dengue virus detection Microfluidic-based genosensor to detect human papillomavirus (HPV16) for head and neck cancer Chemiresistive DNA hybridization sensor with electrospun nanofibers: A method to minimize inter-device variability Diagnosis of mixed infections with swine viruses using an integrated microfluidic platform Electrochemical detection of methylated DNA on a microfluidic chip with nanoelectrokinetic pre-concentration A digital microfluidics platform for loop-mediated isothermal amplification detection Characterization of Virus Capsids and Their Assembly Intermediates by Multicycle Resistive-Pulse Sensing with Four Pores in Series PRESCIENT: platform for the rapid evaluation of antibody success using integrated microfluidics enabled technology Rapid and fully microfluidic Ebola virus detection with CRISPR-Cas13a Label-free detection of influenza viruses using a reduced graphene oxide-based electrochemical immunosensor integrated with a microfluidic platform Hands-free smartphone-based diagnostics for simultaneous detection of Zika, Chikungunya, and Dengue at point-of-care A rapid and label-free platform for virus capture and identification from clinical samples 2020 Capillary transfer of soft films Controlled focused ion beam milling of composite solid state nanopore arrays for molecule sensing Single-molecule analysis with solid-state nanopores Numerical modelling of a nanopore-based resistive-pulse sensor for detection of biomolecules Stable fabrication of a large nanopore by controlled dielectric breakdown in a high-pH solution for the detection of various-sized molecules Solid-state nanopore fabrication by automated controlled breakdown Arsenal of microfluidic testing devices may combat COVID-19 pandemic Fast, portable tests come online to curb coronavirus pandemic Functional Integration of PCR Amplification and Capillary Electrophoresis in a Microfabricated DNA Analysis Device Determination of SARS-coronavirus by a microfluidic chip system Microfluidic immunoassays for sensitive and simultaneous detection of IgG/IgM/Antigen of SARS-CoV-2 within 15 min Ultra-low-cost integrated silicon-based transducer for on-site, genetic detection of pathogens. bioRxiv Initial performance evaluation of a spotted array Mobile Analysis Platform (MAP) for the detection of influenza A/B, RSV, and MERS coronavirus One-pot reverse transcriptional loop-mediated isothermal amplification (RT-LAMP) for detecting MERS-CoV A highly sensitive molecular detection platform for robust and facile diagnosis of middle east respiratory syndrome (MERS) corona virus Multiplex paper-based colorimetric DNA sensor using pyrrolidinyl peptide nucleic acidinduced AgNPs aggregation for detecting MERS-CoV, MTB, and HPV Oligonucleotides Rapid multiplex microfiber-based immunoassay for anti-MERS-CoV antibody detection An integrated passive microfluidic device for rapid detection of influenza a (H1N1) virus by reverse transcription loop-mediated isothermal amplification (RT-LAMP) Solid-State Sensors Influenza A virus-specific aptamers screened by using an integrated microfluidic system A sample-to-answer, portable platform for rapid detection of pathogens with a smartphone interface Integrated microfluidic system for rapid detection of influenza H1N1 virus using a sandwich-based aptamer assay 2020 A structure-free digital microfluidic platform for detection of influenza a virus by using magnetic beads and electromagnetic forces Enhanced Detection of Single Viruses On-Chip via Hydrodynamic Focusing Optofluidic wavelength division multiplexing for single-virus detection Simultaneous and automated detection of influenza A virus hemagglutinin H7 and H9 based on magnetism and size mediated microfluidic chip An integrated microfluidic system for rapid detection and multiple subtyping of influenza A viruses by using glycan-coated magnetic beads and RT-PCR Selective detections of single-viruses using solid-state nanopores Rapid immunodiagnostics of multiple viral infections in an acoustic microstreaming device with serum and saliva samples A non-optical multiplexed PCR diagnostic platform for serotype-specific detection of dengue virus A Multiplexed, point-of-care sensing for dengue 2020 Serological point-of-care and label-free capacitive diagnosis of dengue virus infection The capacitive sensing of NS1 Flavivirus biomarker A dual marker label free electrochemical assay for Flavivirus dengue diagnosis Detection of Zika virus using reverse-transcription LAMP coupled with reverse dot blot analysis in saliva Label-free electrochemical DNA biosensor for zika virus identification Rapid and selective determination of Zika Virus RNA using a Universal DNA-Hairpin probe An ultra-sensitive capacitive microwire sensor for pathogen-specific serum antibody responses A field effect transistor modified with reduced graphene oxide for immunodetection of Ebola virus Microvesicle detection by a reduced graphene oxide field-effect transistor biosensor based on a membrane biotinylation strategy 2020 A handheld continuous-flow real-time fluorescence qPCR system with a PVC microreactor Loop-mediated isothermal amplification of DNA Development and evaluation of a novel loop-mediated isothermal amplification method for rapid detection of severe acute respiratory syndrome coronavirus A simple and multiplex loopmediated isothermal amplification (LAMP) assay for rapid detection of SARS-CoV 2020 Development of a novel reverse transcription loop-mediated isothermal amplification method for rapid detection of SARS-CoV-2 novel coronavirus disease (COVID-19): paving the road for rapid detection and point-of-care diagnostics Resistive-pulse and rectification sensing with glass and carbon nanopipettes Specific and label-free immunosensing of protein-protein interactions with silicon-based immunoFETs Real-time shape approximation and fingerprinting of single proteins using a nanopore Influence of bioreceptor layer structure on myelin basic protein detection using organic field effect transistor-based biosensors A critical insight into the development pipeline of microfluidic immunoassay devices for the sensitive quantitation of protein biomarkers at the point of care Aptamers as targeted therapeutics: current potential and challenges A genotype network reveals homoplastic cycles of convergent evolution in influenza A (H3N2) haemagglutinin A serological assay to detect SARS-CoV-2 seroconversion in humans Detection of antibodies against hepatitis B virus surface antigen and hepatitis C virus core antigen in plasma with a waveguide-mode sensor A novel microfluidic resistive pulse sensor with multiple voltage input channels and a side sensing gate for particle and cell detection Particle detection on microfluidic chips by differential resistive pulse sensing (RPS) method Surveying silicon nitride nanopores for glycomics and heparin quality assurance Means for counting particles suspended in a fluid Resistive-pulse sensing from microbes to molecules A high-throughput label-free nanoparticle analyser 2020 A polymer-based nanoresistive pulse sensor for detection of biomolecules: fabrication and simulation Mechanical characterization of HIV-1 with a solid-state nanopore sensor High-throughput single nanoparticle detection using a feed-through channel-integrated nanopore Selective counting and sizing of single virus particles using fluorescent aptamer-based nanoparticle tracking analysis Universal amplification-free molecular diagnostics by billionfold hierarchical nanofluidic concentration Nanoswitch-linked immunosorbent assay (NLISA) for fast, sensitive, and specific protein detection A polymer microfluidic chip for quantitative detection of multiple water-and foodborne pathogens using real-time fluorogenic loop-mediated isothermal amplification A paper/polymer hybrid microfluidic microplate for rapid quantitative detection of multiple disease biomarkers Miniaturized devices for point of care molecular detection of HIV Pixelated colorimetric nucleic acid assay Development of hand-held point-of-care diagnostic device for detection of multiple cancer and cardiac disease biomarkers Development of a rapid and sensitive electrochemical biosensor for detection of human norovirus via novel specific binding peptides High-sensitive and selective detection of human-iInfectious influenza virus using biomimetic graphene field-effect transistor Novel PMMA Polymer-based nanopores capable of detection and discrimination between structurally different biomolecules Strategies in protein immobilization on a gold surface Ratiometric fluorescence method for ctDNA analysis based on the construction of a DNA four-way junction Four-way junction formation promoting ultrasensitive electrochemical detection of MicroRNA Rapid detection of COVID-19 causative virus (SARS-CoV-2) in human nasopharyngeal swab specimens using field-effect transistor-based biosensor In situ structural analysis of SARS-CoV-2 spike reveals flexibility mediated by three hinges Potent neutralizing antibodies against SARS-CoV-2 identified by highthroughput single-cell sequencing of convalescent patients' B cells Development and clinical application of a rapid IgM-IgG combined antibody test for SARS-CoV-2 infection diagnosis 2020 How nanophotonic label-free biosensors can contribute to rapid and massive diagnostics of respiratory virus infections: COVID-19 Case Latin America and its global partners toil to procure medical supplies as COVID-19 pushes the region to its limit Authors' contributions. J.A.B. conceived of the study, designed the study, carried out the literature review, carried out the design of the figures and drafted the manuscript; R.G.M. participated in the design of the study and drafted the manuscript; S.A. coordinated the study and critically revised the manuscript. All authors gave final approval for publication and agree to be held accountable for the work performed therein.Competing interests. We declare we have no competing interests. Funding. We acknowledge the support of the Natural Sciences and Engineering Research Council of Canada (NSERC).